Best D49M30SB, D49M30BLS, D49M36SB, D49M48SB, D49M36BLS Specification Sheet

CATTURATM DOWNDRAFT
66
MODELS D49M30SB, D49M36SB, D49M48SB,
SPECIFICATIONS
Page 1
D49M30BLS, D49M36BLS
FEATURES
HOUSING:
Galvanized steel construction
Left, right, front, below or rear discharge
Flexible installation - can be used with cooktops, rangetops,
slide-in, and free-standing ranges
30", 36", or 48" widths - Fits standard-size cabinets (Some blower configurations may require deeper cabinets.)
For indoor domestic use only
CHIMNEY ASSEMBLY:
Quiet actuation linear drive system
Chimney rises 18" when activated - ideal for tall pots
Aluminum mesh filters - easy to remove, dishwasher-safe
304 stainless steel chimney - makes cleanup quick and
easy
4-speed capacitive-touch control, with delay off and filter clean reminder
Heat Sentry™ adjusts speed of blower in case of excess heat
2-level LED task light. 7W (30"), 14W (36"), 18W (48")
Up to 100% capture - equal to comparable island hoods
TRIM / DOOR:
Low profile
304 stainless steel construction
Articulating door to hide chimney when retracted
Integrated, capacitive-touch UP button
BLOWER (sold separately):
Compatible with quiet and efficient 600 cfm Flex Blower ­Model PF6
Permanently lubricated, thermally-protected motor
Neoprene, resilient anti-vibration mounts
Can be mounted directly to downdraft or mounted remotely
Uses standard 8" or 10" round duct
Can be rotated on housing to exhaust left, right or down
Compatible with in-line/exterior blower models:
EB6, EB9*, EB12*, EB15*, ILB3, ILB6, ILB9, ILB11*
*
Recommended models
BEST Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711 BEST Drummondville, QC, Canada www.BestRangeHoods.ca 866-737-7770
REFERENCE QTY. REMARKS Project
TM
Complete Capture Design rivals the
TYPICAL SPECIFICATION
Downdraft blower system shall be Best (D49M36SB), (D49M48SB), (D49M30BLS) or (D49M36BLS).
Unit to have stainless steel housing. Chimney to rise 18" and have 304 stainless steel contruction for ease of cleaning.
Filters to be aluminum mesh, easy to remove and dishwasher-safe.
Flex blower will connect directly to 8" round duct. Remote blower will connect directly to 10" round duct. Blower to discharge left, right, front, below or rear.
Motor shall be mounted to blower assembly with grease resistant anti-vibration mounts, be removable, and lifetime lubricated.
Unit to include Heat Sentry excess heat.
Unit to include trim / door to hide chimney when retracted.
Downdraft system shall operate on 120 VAC and be able to be plugged into a standard grounded outlet. It will have a 4-speed blower control, with delay off, and filter clean reminder.
Downdraft shall include 2-level LED task lighting.
Downdraft blower system to be cULus listed.
SPECIFICATIONS
Volts: 120 Hz: 60 Amps: 3.2 Duct: 8" or 10" Round
NOTE: Dimensions shown are for reference only. Before cutting out countertop, refer to instructions packed with downdraft and cooktop.
HB01
®
Model D49M30SB,
, to adjust blower speed in case of
HK0198
NOTE: D ARE IN INCHES.
IMENSIONS SHOWN
Location
Architect
Engineer
Contractor
Submitted by Date
PRODUCT SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
91A 99045243E
CABINET CUTOUTS
!
5-7/8
"
(14.9 cm)
21
"
(53.3
cm
)
1
-
1/8
"
(2.9 cm)
21
"
(5
3.3 cm)
24-3/4
"
(62.9 cm)
CAUTION: BEFORE CUTTING HOLE IN CABINET FOR DUCTWORK, check for interference with floor joists, wall studs, electrical wiring or plumbing.
PLANNING
Page 2
Flex Blower Ducting Remote Location Cutout
Below, Side or Rear Ducting Cutouts
5-7/8"
5-7/8"
(14.9 cm)
(14.9 cm)
Appliance
Cutout
(5.1 cm)
21"
21"
(53.3 cm)
(53.3 cm)
(10.2 cm)
2"
24-3/4"
1
1
-1/8"
-1/8"
(2.9 cm)
(2.9 cm)
24-3/4"
(62.9
(62.9
cm)
cm)
21"
21"
(53.3
(53.3
cm)
cm)
4"
(10.2 cm)
(10.2 cm)
4"
4"
(53.3 cm)
(53.3 cm)
21"
21"
Flex Blower Ducting Cutout
4"
(10.2 cm)
Appliance
Cutout
Center line of downdraft
Ø8"
(20.3 cm)
7-5/8"
7-5/8"
(19.4 cm)
(19.4 cm)
Dimensions based off of Model 432 - 8" round elbow
10" Exterior or In-line Blower Ducting Cutout
Appliance
Cutout
Appliance
Cutout
Ø8"
(20.3 cm)
1-1/2"
(3.8 cm)
(14.3 cm)
(14.3 cm)
Center line of downdraft
5-5/8"
5-5/8"
Center line of downdraft
Ø10"
(25.4 cm)
8-5/8
8-5/8
(21.9 cm)
(21.9 cm)
"
"
Dimensions based off of Model 418 - 10" round elbow
Use the dimensions in illustrations to help plan how and where to provide duct access through your cabinet. A 1-7/8" x 19" rectangular duct can be used through left, right, floor and back of cabinet. Also, 8" round or 10" round can be used through cabinet floor.
For left, right, or rear exhaust:
Allow at least 18" for transition and elbow or blower.
For left / right exhaust:
A 30" deep cabinet is recommended to align properly with flex blower. Flex blower can be mounted to rear cabinet wall or to a platform / frame (not provided) on the base of the cabinet floor. (See flex blower instructions).
Cabinet depths of 24" to 30" are required - depending on the type of cooking appliance.
PLANNING
2-7/8"
A
B
2-3/4"
Downdraft
Cooktop
Front to Back
Inside Cabinet Depth
CountertopCountertop
Page 3
ELECTRICAL PANEL
The unit has a 30-in. power cord with a 3-pronged plug. Plan to provide a grounded outlet within reach of this cord.
DOWNDRAFT
Refer to the cooktop installation instructions for dimensions of cooktop, countertop cut-out, and cabinet requirements. However, it is recommended that oversized cabinets be used for easier installation. Custom island designs need to account for deeper cabinets - especially when installed with a range in front of the downdraft or when mounting the blower behind the downdraft. You must also plan for an access door.
Cooktop depth can vary greatly from one to another. This may cause the fit of these two appliances to be rather tight.
Pay special attention to the areas of potential interference highlighted above. A countertop with (A) a raised lip and/or (B) a backsplash may not allow enough flat countertop for a proper installation. Note that 2-3/4" of flat countertop is required behind cooktop and that 2-7/8" is necessary between the back edge of the cooktop and the inside of cabinet back.
DUCTWORK
HOUSING
FLEX
A
Remote blowers
*
use 8" or 10" round remote discharge plate instead of flex blower.
The downdraft blower system is designed for use with 8" round ductwork using a Flex Blower or 10" round ductwork using a remote blower. (Purchase blowers separately.) Seven (7) different discharge connections are available - with side-to-side adjustment for accurate alignment of ductwork:
A = 8" Round, Left Discharge out of Flex Blower B = 8" Round, Right Discharge out of Flex Blower C = 8" Round, Down Discharge out of Flex Blower (Electrical Panel to be mounted remotely) D = 1-7/8" x 19", Left Discharge out of Housing to Remote Blower or Flex Blower in remote location. Use 1-7/8" x 19" to 8" round transition,
1-7/8" x 19" to 10" round transition, or 1-7/8" x 19" ductwork as appropriate.
E = 1-7/8" x 19", Right Discharge out of Housing to Remote Blower or Flex Blower in remote location. Use 1-7/8" x 19" to 8" round transition,
1-7/8" x 19" to 10" round transition, or 1-7/8" x 19" ductwork as appropriate.
F = 1-7/8" x 19", Rear Discharge out of Housing to Remote Blower or Flex Blower in remote location. Use 1-7/8" x 19" to 8" round transition,
1-7/8" x 19" to 10" round transition, or 1-7/8" x 19" ductwork as appropriate.
G = 1-7/8" x 19", Below Discharge out of Housing to Remote Blower or Flex Blower in remote location. Use 1-7/8" x 19" to 8" round transition,
1-7/8" x 19" to 10" round transition, or 1-7/8" x 19" ductwork as appropriate.
For best performance: Choose the ducting option which allows the shortest length of ductwork and a minimum number of elbows and transitions. Check location of floor joists, wall studs, electrical wiring or plumbing for possible interference.
D
HD1101
BLOWER*
C
F
G
B
E
ELECTRICAL
PANEL
OPTIONAL ACCESSORIES
Page 4
OPTIONAL
ACCESSORY
MODELS
ACRD
ACRDBLS
MODELS
HA0141
ATSKD30 ATSKD36 ATSKD48
MODELS
MD6T MD8T
MD10T
DESCRIPTION /
APPLICATION
REMOTE UP/DOWN CONTROL
Use when you cannot reach the UP/ DOWN Button on the downdraft chimney.
Can be located on counter top, face of cabinetry or on the side cabinet of an island. Cut-out size: 2¼" H x 2" W.
Cannot be used where remote control will interfere with cooking, where hot pans could be set, or where hot liquids could be spilled on the control.
Remote wiring connects with 6-pin connection.
GAS COOKTOP SEAL KIT
Recommended for use with all gas cooktops. Includes trim bracket and trim seal.
30", 36" & 48" widths.
MAKE-UP AIR DAMPER
Use to provide make-up air (when called for) to keep the home comfortable by allowing the downdraft to operate at optimum levels.
Directwire design works with select
®
BEST
downdrafts to balance indoor air pressure by providing interlocked make-up air; damper opens automatically when the range hood is activated.
8" & 10" round diameters.
Connects to 2 CONTACTS on
ELECTRICAL PANEL.
OPTIONAL
ACCESSORY
MODEL AEWD5
MODEL ANKD
MODEL AFCD
MODEL AVDKD8
DESCRIPTION /
APPLICATION
EXTENSION CABLE - 5-FT.
Use where electrical panel is remotely mounted. Extends electrical panel cable an additional 5 feet.
NON-DUCT RECIRCULATING KIT
Use where ducting is not feasible or available. Mount to toe kick or base of a cabinet and attach directly to Model PF6 Flex Blower using 8" round duct. Kit can be rotated so that the exhaust is not directly at your feet. Includes recirculation filter and decorative cover plate.
RECIRCULATION FILTER REPLACEMENT
Replacement filter for ANKD Non-Duct Recirculating Kit. Use to effectively capture cooking contaminants.
1-7/8" X 19" TO 8" ROUND TRANSITION
Rectangular to 8" round transition for left, right, below or rear exhaust - using Model PF6 Flex Blower. Can be attached to downdraft unit or rectangular duct (AEDD2). Includes S-clips for easy, secure attachment.
MODELS ATKD30SB ATKD36SB ATKD48SB
MAKE-UP
AIR DAMPER
CONTACTS
RANGE TRIM KIT
Use with free-standing range - where a gap is present between back of range and downdraft.
30", 36" & 48" widths.
1-7/8" X 19" TO 10" ROUND TRANSITION
Rectangular to 10" round transition for left, right, below or rear exhaust - using external blower. Can be attached to downdraft unit or rectangular duct (AEDD2).
MODEL AVDKD10
RECTANGULAR ADAPTER FOR 1-7/8" X 19"
Use to connect 1-7/8" x 19" rectangular duct directly to downdraft when using side, below or rear exhaust.
MODEL AVDKD219
OPTIONAL ACCESSORIES
Page 5
OPTIONAL
ACCESSORY
MODELS
ATTD1
ATTD1BLS
MODEL ACVPD8
DESCRIPTION /
APPLICATION
END CAP TRIM EXTENSION +1" WIDTH - LH & RH
Use left and right to increase the overall trim width by 1".
FRONT PANEL ROUGH-IN PLATE ­8" ROUND
Use where 8" round duct or elbow attaches to front of airbox (Model PF6 remote blower installation).
FRONT PANEL ROUGH-IN PLATE ­10" ROUND
Use where 10" round duct or elbow attaches to front of airbox (exterior or in-line blower installation).
OPTIONAL
ACCESSORY
HJ0123
MODEL AVDKD8810
DESCRIPTION /
APPLICATION
TRANSITION
Y” (2) - 8" ROUND TO
(1) - 10" ROUND
Galvanized steel construction.
MODEL ACVPD10
MODEL 432 - 8" RD.
MODEL 418 - 10" RD.
MODEL 408 - 8" RD.
MODEL 410 - 10" RD.
MODEL AEDD2
0
90
DUCTWORK ELBOW
Adjustable from straight to 90
0
.
Galvanized steel construction.
STRAIGHT ROUND DUCT - 2-FT.
Galvanized steel construction.
RECTANGULAR DUCT - 2-FT. SECTIONS (1-7/8" X 19")
Galvanized steel construction.
Loading...
+ 11 hidden pages