Best CC34E6SB Installation manual

Model CC34E
ENGLISH.....................................2
FRANÇAIS.................................15
ESPAÑOL.................................. 29
In USA - BEST Hartford, Wisconsin In CANADA - BEST Drummondville, QC, Canada
For additional Information visit www.BestRangeHoods.com
6
SB
READ AND SAVE THESE INSTRUCTIONS
!
!
INTENDED FOR DOMESTIC COOKING ONLY
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means can­not be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Associa­tion (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any separate solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
A. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on low or medium settings.
B. Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette,
Cherries Jubilee, Peppercorn Beef Flambe’).
C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
D. Use proper pan size. Always use cookware appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already know how to operate it. B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
- 2 -
!
CAUTION
1. For indoor use only.
2. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust
air into spaces within walls or ceilings or into attics, crawl spaces, or garages.
3. Take care when using cleaning agents or detergents.
4. Avoid using food products that produce flames under the Range Hood.
5. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and
vapors.
6. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray,
construction dust, etc. off power unit.
7. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes
overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced.
8. For best capture of cooking impurities, the bottom of the hood should be a minimum of 48” and
a maximum of 72” above the cooking surface.
9. Two installers are recommended because of the large size and weight of this hood.
10. The light source is designed for this specific application and can overheat if serviced by untrained
personnel. If any servicing is required, the product should be returned to an authorized service facility for examination or repair.
11. Please read specification label on product for further information and requirements.
To reduce the risk of fire and electric shock, install this range hood only with Best Exterior
12.
Blowers Models EB6, EB9, EB12 and EB15 or Best In-Line Blower Models ILB3, ILB6, ILB9, or ILB11. Other blowers cannot be substituted. (Blowers sold separately).
- 3 -
OPERATION
Controls (Fig. 1)
The hood is operated using the (5) push-buttons located on the hood and the remote control. LED colors are displayed on hood control only.
P1: Activate/deactivate delay-off (10 minute) P2: Filter change indication timer reset
P1
¤
P3 P4
P5
-
P2
+
ƒ
L1 LED RING
(P1) Delay- Off Switch
• Your hood includes a 10 minute blower delay off switch. Press this switch once to activate the
timer and the LED Ring (L1) flashes blue. The blower will continue to operate for 10minutes. After 10 minutes, the blower turns off automatically.
• To cancel the 10-minute delay, press the delay switch once again.
(P2) Filter Alarm Switch
• After 30 hours of blower operation, the filter alarm is activated and the LED ring (L1) turns
red/flashes. It indicates that the grease filters need to be cleaned.
• After cleaning the grease filters, reset the hour counter by pressing the Filter Alarm/Timer
Reset button (P2) during display of the alarm.
P3: Decreases fan motor speed until turned off (4>3>2>1>OFF) P4: Turns fan motor on and increased speed (ON>1>2>3>4) P5: Turns lights on/off L1: LED Indicator Ring Signalling crown:
- Hood in standby: lights up green. 30 seconds after the last key has been pressed the crown turns off
- Motor on: L1 lights up blue frequency is proportional to the speed setting.
- 10’ TIMER function : L1 lights up and flashes blue.
- Filter alarm active: L1 lights up red
The
FIG. 1
(P3) Blower Speed Decrease and Off Switch
• Press to decrease blower speed, high to low. The LED ring (L1) flashes blue at a speed proportionate to the blower setting (i.e.: four flashes is high speed, one flash is low speed, etc.)
• Continue pressing this switch to turn the blower off.
(P4) Blower Speed Increase and On Switch
• Press this switch to turn the blower on to low speed.
• Press again to increase blower speed, low to high. The LED ring (L1) flashes blue at a speed proportionate to the blower setting (i.e.: four flashes is high speed, one flash is low speed, etc.)
(P5) Light Switch
Turns the lights on and off.
Master On-Off Switch
Located behind one of the corner filters, this switch must be ON (indicated as “I”) before the hood will operate. Turn the switch OFF (indicated as “O”) to disconnect power to the hood.
- 4 -
CLEANING AND MAINTENANCE
Proper maintenance of the Range Hood will assure proper performance of the unit.
Motor
The motor is permanently lubricated and never needs oiling. If the motor bearings make excessive or unusual noise, replace the motor with the exact service motor. The impeller should also be replaced.
Grease Filters
The grease filters should be cleaned frequently. Use a warm detergent solution. Grease filters are dishwasher safe.
Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filter may occur if using phosphate detergents, or as a result of local water conditions - but this will not affect filter performance. This discoloration is not covered by the warranty.
See “INSTALL FILTERS” section for removal and installation instructions.
Stainless Steel Cleaning
DO:
• Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.
• Always clean in the direction of original polish lines.
• Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely.
• You may also use a specialized household stainless steel cleaner.
DON’T:
Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt.
• Use any harsh or abrasive cleansers.
• Allow dirt to accumulate.
• Let plaster dust or any other construction residues reach the hood. During construction/ renovation, cover the range hood to make sure no dust sticks to the stainless steel surface.
Avoid: When choosing a detergent
• Any cleaners that contain bleach will attack stainless steel
• Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
• Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should never be used close to a range.
- 5 -
PREPARE THE HOOD
Unpack hood and check contents.
You should receive:
1 - Range Hood Body 1 - Remote Control 6 - Grease Filters 6 - Lag Bolts, 6 x 70 mm 6 - Washers
REMOTE CONTROL
RANGE HOOD
BODY
EXTERIOR OR IN-LINE BLOWER SELECTION
CAUTION:Either an exterior blower or
an in-line blower may be used with this range hood. The Model CC34E6SB range hood must be installed only with Best Exterior Blower Models EB6, EB9, EB12, EB15 or Best In-Line Blower Models ILB3, ILB6, ILB9 or ILB11. Other blowers cannot be substituted. (Blower sold separately).
The blower must be cULus Listed for Canadian and U.S. use, and evaluated for use with a solid-state speed control, rated 120V, 60Hz, 6.0A max.
6 WASHERS
6 LAG BOLTS
(6 x 70 mm)
6 GREASE FILTERS
FIG. 2
- 6 -
INSTALL THE DUCTWORK
METAL
WARNING: To reduce the risk of fire, use only metal ductwork.
WALL
1. Choose the loca-
CAP
tion of the hood, exterior or in-line blower and any roof or wall caps, and decide where the ductwork will run. See Fig. 4 and
IN-LINE BLOWER
(Shown ducted through wall/gable
See in-line blower instructions
for specific duct size &
ducting requirements.
exterior or in-line blower instructions for suggestions.
2. A straight, short
duct run will allow the hood to perform most efficiently. Long duct runs, elbows, and transitions will reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with longer duct runs.
3. Install an exterior or in-line blower.
4. Connect metal ductwork to exterior or in-line blower and work back towards hood location.
Elbows and transitions may be necessary. See exterior or in-line blower instructions for further information. Use duct tape to seal the joints between ductwork sections.
DUCT
).
ELBOW
HOOD
EXTERIOR BLOWER
8" ROUND TO 10” ROUND TRANSITION
48" TO 72" ABOVE
COOKING SURFACE
8" ROUND
METAL DUCT
FIG. 4
PREPARE THE CEILING OPENING
The hood should always be centered over the cooktop. Make sure there is adequate space in the ceiling structure to install the hood and ductwork. The hood should be mounted 48” to 72” above the cook top for best removal of cooking impurities. Fig 4.
Use joist size lumber to frame in around the range hood opening. The ceiling structure must be able to support the weight of the hood (58 pounds). Fig 5.
- 7 -
min. 9-7/16" max. 13-3/4"
DOUBLE HEADERS
26¾”
2
1
/
42
FIG. 5
PREPARE THE HOOD SUPPORT
1. Construct a wood framing system as
shown in Fig. 6.
2. The structure must be capable of support-
ing its own weight, plus the weight of the hood (58 pounds).
2 x 4
FRAMING
11” 11”11” 11”
42-1/2”
- 8 -
1/8” PILOT
1/8” PILOT
HOLE (6)
HOLE (6)
26-3/4”
37-1/4”
2-5/8”
9-5/8"
FIG. 6
INSTALL THE HOOD
CAUTION: At least two installers are recommended because of the large size and weight of this range hood.
1. Lift range hood into the ceiling opening.
2. Secure each support frame to the wooden
hood support frame using (6) 6 x 70 mm
lag bolts and washers provided. Fig. 7.
3. Adjust height of the telescoping support
frame to ensure a tight fit between the
hood and finished ceiling.
4. At the blower discharge collar, connect
ductwork that exhausts air to the outside
discharge. Fig. 8.
5. Duct tape all joints to ensure an air tight
seal.
2x4
WOODEN
FRAME
(6) LAG
BOLTS &
WASHERS
FIG. 7
8” ROUND
DUCT
- 9 -
FIG. 8
CONNECT THE WIRING
WARNING: All electrical wiring
should be done by a qualified person (s) in accordance with all applicable codes and standards. This range hood must be properly grounded.
Do not turn blower on at the service panel until all wires have been connected.
1. From the room interior, pull down both
closure panels. Fig. 9.
2. Remove (4) screws from the electrical
compartment access panel. Slide the panel
sideways to expose the electrical wiring box.
BLOWER CONNECTION AT THE HOOD
1. Run 2-wire plus ground power cable to a ¾”
knockout located on the back of the hood.
Fig. 10.
2. Remove a ¾” electrical knockout from the
back of the hood.
5. From the electrical box marked “MOTOR
CONNECTION”, remove (2) screws that
secure the cover to the metal wiring box.
Fig. 11.
6. Pull 6” of cable into the box and secure with
an appropriate cable clamp.
7. Make electrical connections inside the “MO-
TOR CONNECTION” box. Connect white-
to-white, red-to-black and green-to-ground.
8. Replace the wiring box cover and the
screws. Make sure wires are not pinched
between the cover and box.
CONNECTIONS AT EXTERIOR OR IN-LINE BLOWER
1. Make electrical connections at the exterior
or in-line blower (see blower instructions).
BLOWER CONNECTION AT THE HOOD
1. Run 2-wire plus ground, 120 VAC electrical
power cable to a ¾” knockout located on the
back of the hood. Fig. 10.
2. Remove a ¾” electrical knockout from the
back of the hood.
3. From the electrical box marked “120VAC
INPUT”, remove (2) screws that secure the
cover to the metal wiring box. Fig. 11.
4. Pull 6” of cable into the box and secure with
an appropriate cable clamp.
5. Make electrical connections inside the
“120VAC INPUT” box. Connect white-to-
white, black-to-black and green-to-ground.
6. Replace the wiring box cover and the
screws. Make sure wires are not pinched
between the cover and box.
7. Replace the electrical compartments ac-
cess panel and (4) screws.
CLOSURE PANELS
2-WIRE PLUS
2-WIRE PLUS
GROUND
120 VAC
LINE IN
CONNECTION
KNOCKOUTS
BLOWER AND POWER CONNECTION AT HOOD
POWER CONNECTION CONNECT: WHITE-TO-WHITE BLACK-TO-BLACK GREEN-TO-GROUND
120VAC 60Hz
LINE-IN
BOX MARKED “120VAC INPUT”
BLOWER CONNECTION CONNECT: WHITE-TO-WHITE RED-TO-BLACK GREEN-TO-GROUND
FROM EXTERIOR OR IN-LINE BLOWER
BOX MARKED
CONNECTION”
“MOTOR
- 10 -
FIG. 9
GROUND
BLOWER
FIG. 10
MAIN SWITCH
FIG. 11
INSTALL THE FILTERS
P1: Activate/deactivate delay-off (10 minute) P2: Filter change indication timer reset P3: Decreases fan motor speed until turned off (4>3>2>1>OFF) P4: Turns fan motor on and increased speed (ON>1>2>3>4) P5: Turns lights on/off L1: LED Indicator Ring Signalling crown:
- Hood in standby: lights up green. 30 seconds after the last key has been pressed the crown turns off
- Motor on: L1 lights up blue
The
frequency is proportional to the speed setting.
- 10’ TIMER function : L1 lights up and flashes blue.
- Filter alarm active: L1 lights up red
1. Pull down both closure panels as shown.
2. To install the grease filters, align rear filter
tabs with slots in the hood. Push latch tab
in, push filter into position and release.
Make sure filter is securely engaged after
installation. Fig. 12.
3. To remove the filters for cleaning, push
latch tab in to disengage filter from hood.
Tilt the filter downward and remove. Fig. 13.
PROGRAMMING MODE PROCEDURE
FIG. 12
FIG. 13
The range hood is designed to work with several different blower models. Before us­ing, the control must first be programmed to your blower model, in order to achieve proper operating speeds.
From the chart below:
1. Find the SETUP number that corresponds
to the blower model that is installed with
your range hood.
2. The control is factory-preset to SETUP 3. If
your blower model is listed under SETUP
3, no programming is required. The range
hood is ready to use.
SETUP 1 SETUP 2 SETUP 3 (default)
BLOWER
MODEL
NUMBER
EB6 ILB3 ILB6
EB12
EB15
ILB9
3. For blower models listed under SETUP 1 or 2 follow this program sequence:
A - Power at the service box must be ON
while programming. The blower and lights must be turned off.
B - Press P2 for 3 seconds. The L1 LED
ring will flash at 3 different rates of speed: slow flashing speed = SETUP 1; medium flashing speed = SETUP 2; fastest flashing speed = SETUP 3 (the factory-preset default).
C - To select the proper SETUP, press P3
(-) or P4 (+) to change to SETUP 1, 2 or 3.
D - Once the proper SETUP is found, press
P2 (f) to memorize the SETUP setting.
E - The range hood is now ready to use.
P1
¤
EB9
ILB11
P3 P4
P5
-
ƒ
P2
+
- 11 -
L1 LED RING
WARRANTY
Broan-NuTone LLC (Broan-NuTone) warrants to the original consumer purchaser of Best products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRAN­TIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDES­CENT BULBS, FUSE, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LI­ABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at the address stated below or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
In USA - Best®, 926 W. State Street, Hartford, WI 53027 (800-558-1711) In Canada - Best®, 550 Lemire Blvd., Drummondville, QC J2C 7W9 (866-737-7770) www.BestRangeHoods.com
ONE YEAR LIMITED WARRANTY FOR BEST PRODUCTS
- 12 -
SERVICE PARTS
Model CC34E6SB
KEY NO. PART NO. DESCRIPTION 1 B08092793 FRAME
9 B08087804 GREASE FILTER 16 BE3351504 ELECTRICAL BOX SUPPORT 22 FEEDER 38 B03295595 ELECTRICAL PRINTED CIRCUIT BOARD BOX 56 B08092517 CONNECTION AIR OUTLET 57 B02011341 DAMPER FLAP 62 BE3351505 BLOWER BRACKET 64 B03115251 BOTTON BRACKET 67 B02300995 WIRES
67 WIRES
92 107 115 116 124 125 166 167 223 228 230 234 250 282 283 343 362 415 415 474 477 998 999
-
-
-
-
B02300998
B02300999
BE3350923 B03202287 BE3350233
BE3351530
BE3404989 B08092997 B08080869 B03295596 B03293201 B08080359 B03293193 B03293400 B02011389 BE3404224 B02300907 B08092798 B02011421 B03292596 B03202288 B02300885
B02011376
B080810962 B080813576
B08092501
B06145168
B06103842
B08999140
SWITCH BOARD BOX SUPPORT CABLE STOP FEEDER CABLE CONNECTION BOX FEEDER CABLE CONNECTION BOX COVER BOTTOM TELESCOPIC SKELETON UPPER SUPPORT FRAME ELECTRICAL PRINTED CIRCUIT BOARD ELECTRICAL BOX COVER SWITCH BUTTON CONTROLS PRINTED CIRCUIT BOARD SWITCH BOARD BOX COVER SWITCH BOARD BOX RING NUT MAIN SWITCH SUPPORT MAIN SWITCH CLOSURE PANEL DISPLAY VISOR SPRING FAIRLEAD FAIRLEAD HALOGEN LAMP CLOSING FITTING SET INSTALLATION INSTRUCTIONS SET
CONNECTION AIR OUTLET (INCLUDES KEY No. 56, 57)
ELECTRICAL INSTALLATION ASSEMBLY (INCLUDES KEY No. 22, 38, 166, 167, 208, 282, 283) SWITCH BOX ASSEMBLY (INCLUDES KEY No. 223, 228, 230, 234)
REMOTE CONTROL (COMPLETE)
- 13 -
SERVICE PARTS
Model CC34E6SB
16 38
166
167
22
107
415 (03202288)
282
283
116
115
415 (03292596)
92
AQI
67 (02300995)
230 228 234 223
125
124
57
56
62
1
64
477
362
474
67 (02300999)
343
250
9
- 14 -
Loading...