Best ATKD30SB Installation manual

Cattura Downdraft Installation Parts Guide
Option
Installation
Parts needed
1
Front / Internal / In Cabinet
D49M (30-36-48)
PF6 - Internal blower
ATSKD30,36,48 Gas cooktop seal kit- (If gas cooktop)
408 – 8” Rd Duct / 432 - 8” Elbow (as required)
ANKD – Recirculation kit (optional)
2
Front / Internal / Under Floor
D49M (30-36-48)
PF6 - Internal blower
ATSKD30,36,48 Gas cooktop seal kit- (If gas cooktop)
ACVPD8 – Front panel rough-in plate 8’’ round
408 – 8” Rd Duct / 432 - 8” Elbow (as required)
AEWD5 – 5’ Ext. cable for electrical panel (use up to two if
PF6 blower is mounted more than 4 feet away from
downdraft)
3
Front / External or In-Line
D49M (30-36-48)
EB9, 12, 15, ILB11 – External or in-line blower
ATSKD30,36,48 Gas cooktop seal kit- (If gas cooktop)
ACVPD10 - Front panel rough-in plate 10’’ round
410 – 10” Rd Duct / 418 - 10” Elbow (as required)
4
Rear / Internal / In Cabinet
For Clear Front
For 48” Pro slide in range or
applications with grills
recommend using Option 9
with dual outlet and EB15.
D49M (30-36-48)
PF6 - Internal blower
ATSKD30,36,48 Gas cooktop seal kit- (If gas cooktop)
ATKD30,36SB – Range trim kit (If slide-in range)
AVDKD8 – Transition to 8’’ round
408 – 8” Rd Duct / 432 - 8” Elbow (as required)
ANKD – Recirculation kit (optional)
Accessories for all Applications
ACRD: Remote Up/Down control (optional)
ATTD1: End Cap trim extension to expand width 1”. Includes Left & Right trim caps (optional)
AVDKD219: 1-7/8” x 19” rectangular adaptor. Allows connection of rectangular duct to side or rear
outlets. This can extend narrow duct as far as necessary until it is possible to connect to AVDKD8 or 10 transitions.
AEDD2: 1-7/8” x 19” x 2’ Rectangular duct section to use in conjunction with AVDKD219
643 or 441: 8” or 10” Wall vent
MD6T, MD8T, and MD10T: 6”, 8” and 10” make-up air damper.
641FA, 643FA, and 610FA; 6”, 8” and 10” Fresh Air inlets for use with make-up air damper
Note:
- For Range Top applications that are 48 or with grill, recommend Option 3 with EB15.
- For Slide-in Range applications with grill, recommend Option 9 using dual outlet with EB15.
March 31, 2016 1
Cattura Downdraft Installation Parts Guide
5
Rear / Internal / Under Floor
For Clear Front
For 48” Pro slide in range or
applications with grills
recommend using Option 9
with dual outlet and EB15.
D49M (30-36-48)
PF6 - Internal blower
ATSKD30,36,48 Gas cooktop seal kit- (If gas cooktop)
ATKD30,36SB – Range trim kit (If slide-in range)
408 – 8” Rd Duct / 432 - 8” Elbow (as required)
AEWD5 – 5’ Ext. cable for electrical panel (use up to two if
PF6 blower is mounted more than 4 feet away from
downdraft)
6
Rear / External For Clear Front
For 48” Pro slide in range or
applications with grills
recommend using Option 9
with dual outlet and EB15.
D49M (30-36-48)
EB15 or ILB11 – External or in-line blower
ATSKD30,36,48 Gas cooktop seal kit- (If gas cooktop)
ATKD30,36SB – Range trim kit (If slide-in range)
AVDKD10 – Transition to 10’’ round
410 – 10” Rd Duct / 418 - 10” Elbow (as required)
AEWD5 – 5’ Ext. cable for electrical panel (use up to two if
panel is mounted more than 2 feet away from downdraft)
7
Lft or Rht / Internal / In Cabinet
For Clear Front
For 48” Pro slide in range or
applications with grills
recommend using Option 9
with dual outlet and EB15.
D49M (30-36-48)
PF6 - Internal blower
ATSKD30,36,48 Gas cooktop seal kit- (If gas cooktop)
ATKD30,36SB – Range trim kit (If slide-in range)
AVDKD8 – Transition to 8’’ round
408 – 8” Rd Duct / 432 - 8” Elbow (as required)
AEWD5 – 5’ Ext. cable for electrical panel (use up to two if:
blower is mounted more than 2 feet away from downdraft on
the right - if going left you will need to order a minimum of
one)
ANKD – Recirculation kit (optional)
8
Lft or Rht / Internal / Under
Floor
For Clear Front
For 48” Pro slide in range or
applications with grills
recommend using Option 9
with dual outlet and EB15.
D49M (30-36-48)
PF6 - Internal blower
ATSKD30,36,48 Gas cooktop seal kit- (If gas cooktop)
ATKD30,36SB – Range trim kit (If slide-in range)
AVDKD8 – Transition to 8’’ round
408 – 8” Rd Duct / 432 - 8” Elbow (as required)
AEWD5 – 5’ Ext. cable for electrical panel (use up to two if
PF6 blower is mounted more than 4 feet away from
downdraft)
9
Lft or Rht / External or In-Line
For Clear Front
For 48” Pro slide in range or
applications with grills
recommend using dual outlet
and EB15.
D49M (30-36-48)
EB12, 15, ILB11 – External or in-line blower
ATSKD30,36,48 Gas cooktop seal kit- (If gas cooktop)
ATKD30,36,48SB – Range trim kit (If slide-in range)
AVDKD10 – Transition to 10’’ round (for single outlet)
2 X AVDKD8 – Transition to 8’’ round (for dual outlet)
ATKD8810 – “Y” Transition Two 8” in to one 10” (for dual
outlet)
AEWD5 – 5’ Ext. cable for electrical panel (use up to two if
panel is mounted more than 2 feet away from downdraft)
March 31, 2016 2