Best ANKD Installation

!
!
!
DOWNDRAFT RECIRCULATION KIT
Preliminary
READ AND SAVE THESE INSTRUCTIONS
INTENDED FOR DOMESTIC COOKING ONLY
Model ANKDINSTALLATION INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number in the warranty.
2. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
3. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
4. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
5. To reduce the risk of fire, use only metal ductwork.
PLAN THE INSTALLATION
IMPORTANT - Installation Requirements
The blower can be installed in either of two ways: (1) attached to the downdraft and stabilized with
mounting legs.
(2) installed remotely (not attached to the downdraft),
using mounting brackets and wood framing.
Purchase blower separately. (Includes mounting legs and mounting brackets.)
A minimum 24-inch wide cabinet is recommended. The 8-inch round blower outlet and 8-inch round
recirculation box inlet must align vertically. (See page 2.)
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. Clean filters and grease-laden surfaces frequently.
3. Do not repair or replace any part of this appliance unless specifically recommended in this manual. All other servicing should be done by a qualified technician.
4. Please read specification label on product for further information and requirements.
CONTENTS
1 - Recirculation Box 1 - Recirculation Filter 1 - Decorative Grille 1 - Parts Bag (containing):
6 - #10 x .625” screws 4 - #8 x .375” screws 2 - #8 x 1” screws
3. Determine what lengths of duct are required. (Purchase duct separately.)
A length of flexible or rigid 8” round duct is required to connect blower exhaust to recirculation box inlet.
A length of 3¼” x 14” duct may be required to connect to exhaust of recirculation box and extend to decorative grille location.
FILTER
RECIRCULATION
BOX
OPENING IN
CABINET BASE
1. Determine where recirculation box will exhaust through cabinet.
Front (toe space), Back, Side (Left or Right).
14½” x 15” opening in cabinet base is required for
recirculation box.
3½” x 14¼” opening is required for exhaust.
2. Determine location of recirculation box.
Plan to align blower outlet with recirculation box inlet.
1
14½”
3½” x 14¼”
DECORATIVE
GRILLE
EXHAUST THROUGH CABINET FRONT (TOE SPACE)
EXHAUST OPENING
15”
INSTALL THE RECIRCULATION BOX
Preliminary
Model ANKDINSTALLATION INSTRUCTIONS
1. Cut opening in cabinet base.
Size: 14½” x 15”
Orientation depends upon direction of exhaust.
Double-check that blower outlet and recirculation box inlet will align.
2. Temporarily place recirculation box into opening in cabinet base.
Rotate back of box up slightly and insert exhaust end down into opening.
Mark location of exhaust opening in toe space, rear, or side of cabinet.
3. Remove recirculation box from opening.
4. Cut exhaust opening.
Size: 3½” x 14¼”
This opening will be covered with decorative grille.
5. Replace recirculation box into opening in cabinet base.
If necessary, attach a length 3¼” x 14” duct extension (not included) to extend from recirculation box outlet to decorative grille location.
Seal the duct connection(s) with duct tape to make them secure and air tight.
Use 6 - #10 x .625” screws to secure recirculation box to cabinet base.
6. Install blower.
See blower instructions.
Use 8” round flexible or rigid duct to connect blower exhaust to
recirculation box inlet
Seal the duct connections with duct tape to make them secure and air tight.
Drill 1/8” pilot holes through top of recirculation box and attach legs to recirculation box with 4
- #8 x .375” screws.
7. Install decorative grille.
Use screws provided.
8. Remove polyfilm from filter.
Lift filter from slot.
Remove polyfilm.
Replace filter into slot.
Blower mounted
to downdraft using
mounting legs.
ALIGN BLOWER
OUTLET WITH
RECIRCULATION
BOX INLET
BLOWER
OPTIONAL REMOTE BLOWER MOUNT
Blower mounted to
framing in remote
location - using
mounting brackets.
Blower outlet and
recirculation box
inlet must align.
(See below.)
METAL 8” ROUND
FLEXIBLE OR RIGID
DUCT (per local codes)
MOUNTING
BLOWER
LEGS
EXHAUST THROUGH CABINET SIDE
14½”
15”
EXHAUST THROUGH CABINET BACK
14½”
15”
DIMENSIONS
EXHAUST THROUGH
CABINET FRONT (TOE SPACE)
EXHAUST THROUGH
CABINET SIDE
FILTER REPLACEMENT
It is recommended that you replace the recirculation filter every 6 months. However, this may vary, depending upon the type and amount of cooking you do. Call customer service or your local distributor to order filter replacement Model AFCD.
EXHAUST THROUGH
CABINET BACK
CUSTOM-MADE DECORATIVE GRILLE
You can make your own decorative grille. Use the decorative grille in this kit as a template for the overall size and mounting hole locations. The grille opening pattern is up to you.
Equivalent area of grille slots for proper air flow = 18 in.
2
2
min.
Modèle ANKDGUIDE D’INSTALLATION
!
!
!
Preliminary
ENSEMBLE DE RECIRCULATION POUR HOTTE ENCASTRÉE
LIRE CES DIRECTIVES ET LES CONSERVER
POUR USAGE DOMESTIQUE SEULEMENT
AVERTISSEMENT
OBSERVEZ LES DIRECTIVES CI-DESSOUS AFIN DE RÉDUIRE LES RISQUES D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES CORPORELLES :
1. N’utilisez cet appareil que de la manière prévue par le fabricant. Si vous avez des questions, communiquez avec le fabricant à l’adresse ou au numéro de téléphone indiqués dans la garantie.
2. La pose de l’appareil et les travaux d’électricité doivent être effectués par des personnes qualifiées conformément à la réglementation en vigueur, notamment les normes de la construction ayant trait à la protection contre les incendies.
3. Pour éviter les refoulements, l’apport d’air doit être suffisant pour brûler les gaz produits par les appareils à combustion et les évacuer dans le conduit de fumée (cheminée). Respectez les directives du fabricant de l’appareil de chauffage et les normes de sécurité, notamment celles publiées par la National Fire Protection Association (NFPA), l’American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) et les codes des autorités locales.
4. Veillez à ne pas endommager le câblage électrique ou d’autres équipements non apparents lors de la découpe ou du perçage du mur ou du plafond.
5. Pour réduire les risques d’incendie, utilisez seulement des conduits en métal.
PLANIFICATION DE L’INSTALLATION
IMPORTANT - Exigences d’installation Il y a deux façons d’installer le ventilateur : (1) fixé à la hotte encastrée et stabilisé par des pieds
de montage.
(2) installé à distance (et non rattaché à la hotte), à l’aide
de brides de montage et d’une charpente en poids.
Veuillez acheter le ventilateur séparément. (Comprend les pieds et brides de montage.)
Une armoire d’au moins 61 cm (24 po) de largeur est recommandée.
La sortie ronde de 20,3 cm (8 po) du ventilateur et l’ouverture d’admission ronde 20,3 cm (8 po) du boîtier de recirculation doivent être alignées verticalement. (Voir page 4.)
1. Déterminez l’emplacement de la sortie du boîtier de recirculation au travers de l’armoire.
Avant (coup de pied), arrière, côté (gauche ou droit).
Une ouverture dans la base de l’armoire de
36,8 cm x 38,1 cm (14½ po x 15 po) est nécessaire pour le boîtier de recirculation.
Une ouverture de 8,9 cm x 36,2 cm (3½ po x 14¼ po)
est nécessaire pour la sortie.
2. Déterminez l’emplacement du boîtier de recirculation.
Prévoyez aligner la sortie du ventilateur avec l’admission
du boîtier de recirculation.
ATTENTION
1. Pour ventilation générale uniquement. N’utilisez pas cet appareil pour évacuer des matières ou des vapeurs dangereuses ou explosives.
2. Nettoyez fréquemment les filtres et les surfaces graisseuses.
3. Ne réparez ou ne remplacez aucune pièce de cet appareil à moins que ce manuel le recommande précisément. Tout autre travail de réparation doit être confié à un technicien qualifié.
4. Veuillez lire l’étiquette de spécifications du produit pour obtenir plus de renseignements, notamment sur les exigences.
CONTENU
1 - Boîtier de recirculation 1 - Filtre de recirculation 1 - Grille décorative 1 - Sac de pièces (contenant) : 6 - Vis n° 10 x 0,625 po 4 - Vis n° 8 x 0,375 po 2 - Vis n° 8 x 1 po
3. Déterminez quelles longueurs de conduit sont requises.
(Conduits vendus séparément.)
Une longueur de conduit rond flexible ou rigide de 20,3 cm (8 po) est nécessaire pour raccorder la sortie du ventilateur à l’admission du boîtier de recirculation.
Une longueur de conduit de 8,3 cm x 35,6 cm (3¼ po x 14 po) peut être nécessaire pour raccorder la sortie du boîtier de recirculation jusqu’à la grille décorative d’évacuation.
FILTRE
BOÎTIER DE
RECIRCULATION
OUVERTURE
DANS LA BASE
DE L’ARMOIRE
3
36,8 cm
(14½ po)
SORTIE DE 8,9 CM X 36,2 CM
GRILLE
DÉCORATIVE
SORTIE À L’AVANT DE L’ARMOIRE (COUP DE PIED)
(3½ PO X 14¼ PO)
38,1 cm (15 po)