Besantek BST-MG06 Manual Instruction

BST-MG06 Multi-gas Detecting Alarm
Manual Instruction
1
This BST-MG06 multi gas detecting alarm is applied to underground coal mine, petrochemical industry, municipal, environmental protection and other spaces where multi gas may exist.This device can be used for detecting methane (CH
hydrogen sulfide (H
2S) gases simultaneously. When the concentration of any gas in the environment
is higher or lower than that of set alarm point, this device with send out both sound and light alarms to warn users who wears it to take protective actions. This device is portable and can be also used as a
fixed device. It’s anti-explosion and intrinsically safe, the anti-explosion sign is ExibΙ
1. Application
2. Working principle
In this device, the methane/combustible gas sensor adopts hot catalytic working principle and it consists of black and white elements inside. The black element is the catalytic carrier of methane/combustible gas, and will occur thermal catalytic reaction with the methane/LEL gas to change its own resistance value; the white element is a pure carrier and its resistance value is very stable. According to this sensor’s characteristics, the signal is enlarged by the wheatstone bridge and displays the value, thus concentration detection methane/ combustible gas is achieved.
3. Charging this device
Notice: To charge the battery, ensure you are in a safe, non-hazardous area.
Input voltage: 110-240V, 50-60Hz Output voltage: 5V, 500mA. It can be charged from 5V USB socket through connecting USB cord with this device.
USB socket could from computer, phone adapter, power station, etc.
After connecting USB cord with this device, green LED flashing indicates regularly charging.
When green LED stops flashing and remains light, it indicates charging is basically completed, to enlarge battery life, please don’t unplug charging device right away, instead remain it on charge for another hour.
< >
The CO sensor, O2 sensor and H2S sensor all adopt electrochemical principle. The inside electrode will react with the being detected gases in the role of catalyst to achieve the directional movement of electron between electrodes, and make the electrical signal amplified and displayed by amplifying circuit technology and other existing technologies so that to achieve the detection of concentration.
4. The drawing sketches for all components of this device.
1
2
3
4
5
6
7
8
9
10
11
12
13
Item Description
face cover
alarm light
front cover
lcd
usb port
buttons
buzzer
knob
screw
back cover
lable
calibration mask
5. Technical specification: ( 1ppm=1X 10 )
-6
Technical specification Parameter
Detecting gas
Measurement range
Measurement error
Respond time
CH
4/LEL CO O2 H2S
CH
4
( 0.00~1.00 ) %CH4: ±0.10%CH4 ( 1.00~3.00 ) %CH4: true value ±10%
( 3.00~5.00 ) %CH
4: ±0.30%CH4
≤20S ( T90 )
(0.00~5.00)%Vol
Resolution
Alarm point
0.01%vol
1.00%volcan be adjusted in whole range
clip
optional
optional
2
Technical specification
Parameter
Measurement error
Measurement error
Measurement error
Measurement error
Respond time
Respond time
Respond time
Respond time
LEL
Resolution
Resolution
Resolution
CO
Alarm point
Alarm point
Measurement range
Measurement range
Measurement range
Measurement range
O
2
Low Alarm point
( 0~1000 ppm ( 0~20 ) ppm: ±2ppm
( >20~100 )ppm: ±4ppm
(> 100~500 )ppm: true value ±5%
( >500~1000) %ppm: true value ±6%
≤45
S ( T90 )
1ppm
24ppmcan be adjusted in whole range
0.0 ~ 30.0
( 0.0~5.0 ) %vol±0.5%vol
( >5.0~30.0 )%vol: 0.9%vol
≤35S ( T90 )
0.1%vol
18.0%volcan be adjusted in whole range
25.0%volcan be adjusted in whole range
( 0 ~ 100 )ppm ( 0~50 ) ppm: ±3ppm
( >50~100 )ppm: True value ±10%
≤45
S ( T90 )
( 0 ~ 100 ) %LEL
( 1 ~ 20 )LEL
: ±2%LEL
( 60 ~ 100 ) %LEL: ±6%LEL
( 20 ~ 60 ) %LEL: true value ±2%
1%LEL
≤20
S ( T90 )
20%LELcan be adjusted in whole range
High alarm point
H
2S
3
%vol