Models using TO357 Series (Double Ended Halogen 120V)
TO357, Rev.6 6-10
6695 Taylor Rd. Blacklick, OH 43004
www.besalighting.com
Use With
these Models:
• Trio 12
(9682xx)
Caution: Turn o power to electrical box before installing
F
G
C
B
H
M
J
A
D
E
O
I
L
Back of Socket
N
If socket should become jammed while lamping
or relamping, push in the back portion of the
IMPORTANT:
Insert Lamp as shown
IMPORTANT:
socket to release.
1. Carefully unpack parts. Remove Mounting Strap (A) from Canopy (H). Position Mounting Strap
onto Outlet box then mark ceiling for placement of Anchors (C). Install Anchors into ceiling,
then attach Mounting Strap to Anchors with short Pan Head Screws (D) and to Outlet Box
with Machine Screws (B).
2. Thread the Threaded Studs (E) into the Mounting Strap as shown.
3. Connect bare Ground Wires from fixture and Strap to supply ground with wire nut connector (F).
4. Connect the fixture conductors to the supply conductors with wire nut connectors (G) as shown:
White fixture wires to white supply wire and black fixture wires to black supply wire. Carefully
push wires and wire nuts back into outlet box.
5. Place the fixture Canopy (H) over the outlet box so that the Threaded Studs protrudes
through the slotted holes in canopy.
6. Secure the Canopy to the ceiling with the Thumb Nuts (I), as shown.
7. Install provided bulb (J) into spring loaded sockets, inserting into socket with white wire first.
Do not exceed the wattage marked (150 Watts), as that could cause fixture to overheat.
8. To attach Glass Diffuser, seat the Glass Rim (L) into the slots of the two Fixed Glass Knobs (M).
Then lift up the glass to the Adjustable Glass Knob (N) and tighten Adjusting Screw (O) until the
rim of glass positioned fully into the slot. DO NOT OVERTIGHTEN.
9. Restore power.
CAUTION-RISK OF FIRE: Min 90C SUPPLY CONDUCTORS. This xture requires that the branch supply wires
be rated: MIN 90C. Most dwellings built before 1985 have supply wire rated 60C.
CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR.
All electrical connections and the installation of this xture must be in agreement with local codes,
ordinances or the NEC (National Electric Code) or CEC (Canadian Electrical Code).
Do not connect this xture to an electrical system that does not provide a means for equipment grounding.
Page 2
CEILING FIXTURE INSTALLATION GUIDE
Models using TO358 Series (Double Ended Halogen 120V)
TO358, Rev.6 6-10
6695 Taylor Rd. Blacklick, OH 43004
www.besalighting.com
Use With
these Models:
• Trio 16
(9681xx)
Caution: Turn o power to electrical box before installing
F
G
C
B
H
M
J
A
D
E
O
I
L
Back of Socket
N
If socket should become jammed while lamping
or relamping, push in the back portion of the
IMPORTANT:
Insert Lamp as shown
IMPORTANT:
socket to release.
1. Carefully unpack parts. Remove Mounting Strap (A) from Canopy (H). Position Mounting Strap
onto Outlet box then mark ceiling for placement of Anchors (C). Install Anchors into ceiling,
then attach Mounting Strap to Anchors with short Pan Head Screws (D) and to Outlet Box
with Machine Screws (B).
2. Thread the Threaded Studs (E) into the Mounting Strap as shown.
3. Connect bare Ground Wires from fixture and Strap to supply ground with wire nut connector (F).
4. Connect the fixture conductors to the supply conductors with wire nut connectors (G) as shown:
White fixture wires to white supply wire and black fixture wires to black supply wire. Carefully
push wires and wire nuts back into outlet box.
5. Place the fixture Canopy (H) over the outlet box so that the Threaded Studs protrudes
through the slotted holes in canopy.
6. Secure the Canopy to the ceiling with the Thumb Nuts (I), as shown.
7. Install provided bulb (J) into spring loaded sockets, inserting into socket with white wire first.
Do not exceed the wattage marked (150 Watts), as that could cause fixture to overheat.
8. To attach Glass Diffuser, seat the Glass Rim (L) into the slots of the two Fixed Glass Knobs (M).
Then lift up the glass to the Adjustable Glass Knob (N) and tighten Adjusting Screw (O) until the
rim of glass positioned fully into the slot. DO NOT OVERTIGHTEN.
9. Restore power.
CAUTION-RISK OF FIRE: Min 90C SUPPLY CONDUCTORS. This xture requires that the branch supply wires
be rated: MIN 90C. Most dwellings built before 1985 have supply wire rated 60C.
CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR.
All electrical connections and the installation of this xture must be in agreement with local codes,
ordinances or the NEC (National Electric Code) or CEC (Canadian Electrical Code).
Do not connect this xture to an electrical system that does not provide a means for equipment grounding.
Page 3
CEILING FIXTURE INSTALLATION GUIDE
Models using TO359 Series (Double Ended Halogen 120V)
TO359, Rev.6 6-10
6695 Taylor Rd. Blacklick, OH 43004
www.besalighting.com
Use With
these Models:
• Trio 20
(9680xx)
Caution: Turn o power to electrical box before installing
F
G
C
B
H
M
J
A
D
E
O
I
L
Back of Socket
N
If socket should become jammed while lamping
or relamping, push in the back portion of the
IMPORTANT:
Insert Lamp as shown
IMPORTANT:
socket to release.
1. Carefully unpack parts. Remove Mounting Strap (A) from Canopy (H). Position Mounting Strap
onto Outlet box then mark ceiling for placement of Anchors (C). Install Anchors into ceiling,
then attach Mounting Strap to Anchors with short Pan Head Screws (D) and to Outlet Box
with Machine Screws (B).
2. Thread the Threaded Studs (E) into the Mounting Strap as shown.
3. Connect bare Ground Wires from fixture and Strap to supply ground with wire nut connector (F).
4. Connect the fixture conductors to the supply conductors with wire nut connectors (G) as shown:
White fixture wires to white supply wire and black fixture wires to black supply wire. Carefully
push wires and wire nuts back into outlet box.
5. Place the fixture Canopy (H) over the outlet box so that the Threaded Studs protrudes
through the slotted holes in canopy.
6. Secure the Canopy to the ceiling with the Thumb Nuts (I), as shown.
7. Install provided bulb (J) into spring loaded sockets, inserting into socket with white wire first.
Do not exceed the wattage marked (150 Watts), as that could cause fixture to overheat.
8. To attach Glass Diffuser, seat the Glass Rim (L) into the slots of the two Fixed Glass Knobs (M).
Then lift up the glass to the Adjustable Glass Knob (N) and tighten Adjusting Screw (O) until the
rim of glass positioned fully into the slot. DO NOT OVERTIGHTEN.
9. Restore power.
CAUTION-RISK OF FIRE: Min 90C SUPPLY CONDUCTORS. This xture requires that the branch supply wires
be rated: MIN 90C. Most dwellings built before 1985 have supply wire rated 60C.
CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR.
All electrical connections and the installation of this xture must be in agreement with local codes,
ordinances or the NEC (National Electric Code) or CEC (Canadian Electrical Code).
Do not connect this xture to an electrical system that does not provide a means for equipment grounding.
Page 4
CEILING FIXTURE INSTALLATION GUIDE
Models using TO367 Series (Med. Base 120V)
TO367, Rev.5 6-10
6695 Taylor Rd. Blacklick, OH 43004
www.besalighting.com
Use With
these Models:
• Trio 12
(9682xx)
Caution: Turn o power to electrical box before installing
D
F
C
J
E
A
B
L
G
H
I
K
1. Carefully unpack parts. Fasten Mounting Strap (A) to Outlet box with Machine Screws (B).
2. Thread the Threaded Nipple (C) into the Mounting Strap as shown.
3. Connect bare Ground Wires from fixture and Strap to supply ground with wire nut connector (D).
4. Connect the fixture conductors to the supply conductors with wire nut connectors (E) as shown:
White fixture wires to white supply wire and black fixture wires to black supply wire. Carefully
push wires and wire nuts back into outlet box.
5. Place the fixture Canopy (F) over the outlet box so that the Threaded Studs protrudes
through the two mounting holes in canopy.
6. Secure the Canopy to the ceiling with the Star Washer (G) and Cap Nut (H), as shown.
Tighten the cap nut firmly by using Pliers.
7. Insert screw-in incandescent bulb(s) into socket at wattage no greater than marked on the
fixture label MAX 100W Type A 120V.
8. To attach Glass Diffuser, seat the Glass Rim (I) into the slots of the two Fixed Glass Knobs (J).
Then lift up the glass to the Adjustable Glass Knob (K) and tighten Adjusting Screw (L) until the
rim of glass positioned fully into the slot. DO NOT OVERTIGHTEN.
9. Restore power.
CAUTION-RISK OF FIRE: Min 90C SUPPLY CONDUCTORS. This xture requires that the branch supply wires
be rated: MIN 90C. Most dwellings built before 1985 have supply wire rated 60C.
CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR.
All electrical connections and the installation of this xture must be in agreement with local codes,
ordinances or the NEC (National Electric Code) or CEC (Canadian Electrical Code).
Do not connect this xture to an electrical system that does not provide a means for equipment grounding.
Page 5
CEILING FIXTURE INSTALLATION GUIDE
Models using TO368 Series (Med Base 120V)
TO368, Rev.4 6-10
6695 Taylor Rd. Blacklick, OH 43004
www.besalighting.com
Use With
these Models:
• Trio 16
(9681xx)
Caution: Turn o power to electrical box before installing
F
H
K
G
B
C
A
D
E
M
L
I
J
1. Carefully unpack parts. Remove Mounting Strap (A) from Canopy (H). Position Mounting Strap
onto Outlet box then mark ceiling for placement of Anchors (C). Install Anchors into ceiling,
then attach Mounting Strap to Anchors with short Pan Head Screws (D) and to Outlet Box
with Machine Screws (B).
2. Thread the Threaded Studs (E) into the Mounting Strap as shown.
3. Connect bare Ground Wires from fixture and Strap to supply ground with wire nut connector (F).
4. Connect the fixture conductors to the supply conductors with wire nut connectors (G) as shown:
White fixture wires to white supply wire and black fixture wires to black supply wire. Carefully
push wires and wire nuts back into outlet box.
5. Place the fixture Canopy (H) over the outlet box so that the Threaded Studs protrudes
through the slotted holes in canopy.
6. Secure the Canopy to the ceiling with the Thumb Nuts (I), as shown.
7. Insert screw-in incandescent bulb(s) into socket at wattage no greater than marked on the
fixture label MAX 100W Type A 120V.
8. To attach Glass Diffuser, seat the Glass Rim (J) into the slots of the two Fixed Glass Knobs (K).
Then lift up the glass to the Adjustable Glass Knob (L) and tighten Adjusting Screw (M) until the
rim of glass positioned fully into the slot. DO NOT OVERTIGHTEN.
9. Restore power.
CAUTION-RISK OF FIRE: Min 90C SUPPLY CONDUCTORS. This xture requires that the branch supply wires
be rated: MIN 90C. Most dwellings built before 1985 have supply wire rated 60C.
CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR.
All electrical connections and the installation of this xture must be in agreement with local codes,
ordinances or the NEC (National Electric Code) or CEC (Canadian Electrical Code).
Do not connect this xture to an electrical system that does not provide a means for equipment grounding.
Page 6
CEILING FIXTURE INSTALLATION GUIDE
Models using TO369 Series (Med Base 120V)
TO369, Rev.5 6-10
6695 Taylor Rd. Blacklick, OH 43004
www.besalighting.com
Use With
these Models:
• Trio 20
(9680xx)
Caution: Turn o power to electrical box before installing
F
H
K
G
B
C
A
D
E
M
L
I
J
1. Carefully unpack parts. Remove Mounting Strap (A) from Canopy (H). Position Mounting Strap
onto Outlet box then mark ceiling for placement of Anchors (C). Install Anchors into ceiling,
then attach Mounting Strap to Anchors with short Pan Head Screws (D) and to Outlet Box
with Machine Screws (B).
2. Thread the Threaded Studs (E) into the Mounting Strap as shown.
3. Connect bare Ground Wires from fixture and Strap to supply ground with wire nut connector (F).
4. Connect the fixture conductors to the supply conductors with wire nut connectors (G) as shown:
White fixture wires to white supply wire and black fixture wires to black supply wire. Carefully
push wires and wire nuts back into outlet box.
5. Place the fixture Canopy (H) over the outlet box so that the Threaded Studs protrudes
through the slotted holes in canopy.
6. Secure the Canopy to the ceiling with the Thumb Nuts (I), as shown.
7. Insert screw-in incandescent bulb(s) into socket at wattage no greater than marked on the
fixture label MAX 100W Type A 120V.
8. To attach Glass Diffuser, seat the Glass Rim (J) into the slots of the two Fixed Glass Knobs (K).
Then lift up the glass to the Adjustable Glass Knob (L) and tighten Adjusting Screw (M) until the
rim of glass positioned fully into the slot. DO NOT OVERTIGHTEN.
9. Restore power.
CAUTION-RISK OF FIRE: Min 90C SUPPLY CONDUCTORS. This xture requires that the branch supply wires
be rated: MIN 90C. Most dwellings built before 1985 have supply wire rated 60C.
CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR.
All electrical connections and the installation of this xture must be in agreement with local codes,
ordinances or the NEC (National Electric Code) or CEC (Canadian Electrical Code).
Do not connect this xture to an electrical system that does not provide a means for equipment grounding.