Besa Lighting Rail Connectors User Manual

INSTALLATION GUIDE
Model DCONN Isolating Rail Connector (For use with Besa low voltage lighting systems only)
DCONN, Rev.2 2-09
IMPORTANT SAFETY INSTRUCTIONS:
A) Read all instructions. B) Do not conceal or extend exposed conductors through a building wall. C) Do not install this system in wet locations. D) For low voltage exposed insulated conductor systems required by 30.1(c) do not install
any part of this system less than 7 feet (2.2m) above the floor. E) To reduce the risk of fire and burns, do not install this lighting system where the exposed
bare conductors can be shorted or contact any conductive materials. F) To reduce the risk of fire and overheating, make sure all connections are tight. G) Do not install any luminaire closer than 6 inches (15.25 cm) from any curtain, or similar combustable materials. H) Turn off electrical power before modifying the lighting system in any way.
6695 Taylor Rd. Blacklick, OH 43004
www.besalighting.com
Isolating Rail Connector
Philips Set Screw
1. Loosen set screw on the Isolating Rail Connector, then carefully slide the Rail Sections into each end.
2. Retighten Set Screw to secure Rail Sections together.
Rail Section
SAVE THESE INSTRUCTIONS
INSTALLATION GUIDE
Model ICONN Live Rail Connector (For use with Besa low voltage lighting systems only)
TICONN-SN, Rev.3 7-09
1. Loosen set screw on the Live Rail Connector, then carefully slide the Rail Sections into each end. IMPORTANT: Use the Live Rail Connector on the factory-cut ends of the rail only.
2. Retighten Set Screw to secure Rail Sections together.
Live Rail Connector
6695 Taylor Rd. Blacklick, OH 43004
www.besalighting.com
Rail Section
Factory-Cut End only (Do not insert field-cut end)
Philips Set Screw