
INSTALLATION GUIDE
Model 1KX (Cable Pendant Set 120V)
1KX, Rev.7 12-11
CAUTION: Turn off power to electrical box before installing
6695 Taylor Rd. Blacklick, OH 43004
www.besalighting.com
1. Carefully unpack parts. Remove the
Canopy (A) from the Mounting Plate
by unscrewing the Retainer (B).
Fully remove the Retainer from the
threaded nipple, then pull the canopy
from the Mounting Plate.
B
2. Prior to mounting fixture to ceiling, cord must be cut to length.
Measure the overall length of pendant drop, then add 25% to
allow for shaping of the cord. Cut off excess cord then strip back
outer jacket about 4” in length. To move the Strain Relief (I),
simply pinch together and slide down the cord.
3. Install the provided Mounting Screws (C) into the Outlet Box,
leaving 1/4” of threading as shown. Attach the bare copper fixture
ground wire and bare (or green striped) ground conductor from the
cord to the supply ground and secure with Wire Nut Connector (D).
Connect the cord conductors to the supply conductors with Wire Nut
Connectors (E) as shown: Cord conductor with white stripe to white
supply wire and clear cord conductor to black supply wire. Carefully
push wires and wire nuts back into outlet box.
A
White
Stripe
Clear
D
E
Bare or Green Stripe
C
FG
When using the clear style cord, it is advised that
the installer confirm the polarity per instructions on
the next page.
4. Align the circular openings of the keyhole slots (F) of the Mounting
Plate (G) with the Mounting Screws. Push the Mounting Plate up over
the Outlet Box until tight to ceiling, then rotate the Mounting Plate
Counter-clockwise and secure with Mounting Screws.
5. To adjust pendant height, push the cable up through the Cable Grip (H)
to desired length. To lower pendant, push the Cable Grip up, which will
release the cable and allow it to be lowered. Trim the excess cable,
leaving about 6” above the Cable Grip. Position the Strain Relief close
to the Mounting Plate as shown.
6. Replace the Canopy as shown and secure with the Retainer. Tighten
the Retainer enough to hold the Canopy to the ceiling but do not overtighten.
The cord can now be shaped by positioning the clear Cord Rings (J) along
the cable as desired.
Overtightening can cause the Retainer to be difficult
to unscrew. If this occurs, usually rotating the canopy
counter-clockwise will help to unlock the Retainer.
I
H
J
Replacement parts for this 120V Voltage Pendant Set are as follows:
#T1KX-SN - 100W 10’ clear cordset and 1 support cables with Nickel Hardware.
For Bronze cordset, use “BR” in place ”SN”. For 15’ cordset, place “L” after metal finish.

INSTALLATION GUIDE
Use With
these Models:
• Porto
(4202xx)
• Pape
(4913xx)
• Lucia
(1697xx)
• Luna
(4776xx)
• Tessa
(4201xx)
POLARITY INSTRUCTIONS
Using a Continuity Tester or Multimeter,
confirm the following connections:
• Clear Conductor with White Stripe (Neutral/White)
is connected to the Socket Screwshell. This wire is
to be connected to house supply white conductor.
• Clear Conductor (Hot/Black) is connected
to the Socket Center Contact. This wire is
to be connected to house supply black wire.
7. The installation method for the glass shade as shown,
either with single glass or double glass. Install bulb per
the labeling on the fixture. To adjust the balancing of the
glass, if necessary, see the instructions below.
SOCKET
SCREWSHELL
SOCKET
CENTER CONTACT
Outside
Glass Shade
Visually inspect the
shade to determine if
repositioning is
necessary.
8. Restore power.
Glass Shade
Check Ring
Allen Screw
Slightly loosen the
shade and rotate so
that the unbalanced
portion is parallel with
the allen screw.
Loosen the allen
screw, then rotate
assembly into a new
position that will level
the glass shade.
Check Ring
Inside
Glass Shade
Check Ring
Hold the shade in
it’s new position,
then tighten the allen
screw firmly. Release
the glass shade and
visually confirm that it
is now level.
All electrical connections and the installation of this fixture must be in agreement with local codes,
ordinances or the NEC (National Electric Code) or CEC (Canadian Electrical Code).
Do not connect this fixture to an electrical system that does not provide a means for equipment grounding.