Besa Lighting Groove User Manual

FIXTURE INSTALLATION GUIDE
Models SR/SW Series (Two, Three, and Four Light Vanity 120V)
SR.96 Bath, Rev.1 8-12
6695 Taylor Rd. Blacklick, OH 43004
www.besalighting.com
Use With these Models:
• SR Groove
(6773MR)
Caution: Turn off power to electrical box before installing
A
D
C
B
E
G
K
L
1. Carefully unpack and remove Hex Head Screws(J), releasing Mounting Plate(A) from Canopy(H).
Important: Before proceeding, confirm your mounting scenario. For a Downlighting scenario, the Socketholders(M) must be inverted (see Diagram A). For a low-profile look, the Decorative Finial may be replaced with a Decorative Cap (see Diagram B).
2. If installing to an Outlex Box, extend supply wiring through the Crossbar(C) and secure to the Outlet Box with machine screws(B) provided. For offset purposes where outlet box is to be
off-center, use additional wood screws and wall anchors for support in lieu of the crossbar. If an Outlet Box is not present, eliminate the use of the Crossbar and Box Cover(D) and proceed to step #3. A romex or BX clamp is advised when using flexible cable.
J
F
NOTE: 3-Light fixture shown is for instructional purposes, actual luminaire may be 2-Light or 4-Light as well. Box Cover shape will vary by Model Number.
M
H
3. Place the Box Cover(D) and Mounting Plate(A) over Crossbar for placement of Wall Anchors(E). After installing Anchors, reposition the Box Cover and Mounting Plate and secure with the Cap Nuts(F). Then secure the ends of the Mounting Plate by threading the Wood Screws(G) into the Wall Anchors.
4. Attach the Fixture Ground wire to the supply ground and secure with Wire Nut connector (K).
5. Connect the fixture conductors to the supply conductors with wire nut connectors (L) as shown: White fixture wire to white supply wire and black fixture wire to black supply wire. Carefully push wires and wire nuts back into outlet box.
6. Place the fixture Canopy (H) over the Mounting Plate so that the threaded openings in the Mounting Plate align with the two holes in Canopy. Secure with two Hex Head Screws.
CHECK RING
7. Install the Glass Shade per diagram.
8. Install bulb provided (40W Max., Type G9) and restore power
NOTE: Glass shown is for instructional purposes. Actual Glass may vary in shape or size
All electrical connections and the installation of this fixture must be in agreement with local codes, ordinances or the NEC (National Electric Code) or CEC (Canadian Electrical Code). Do not connect this fixture to an electrical system that does not provide a means for equipment grounding.
FIXTURE INSTALLATION GUIDE
6695 Taylor Rd. Blacklick, OH 43004
CAUTION: Turn off power to electrical box before installing
Loosen the Hex Nut inside canopy, releasing the Socketholder. Rotate the Socketholder into a downward position.
Hold the Socketholder against the canopy and secure with the Hex Nut.
www.besalighting.com
DIAGRAM A (Inverting Socketholders for Downlighting)
Using Hex Wrench provided, loosen the Set Screw on the Socketholder, releasing the Decorative Finial. Pressure may need to be applied to fully remove the finial.
Replace the Decorative Finial with the Decorative Cap
Tighten the Set Screw to secure the Decorative Cap
DIAGRAM B (Replacing Decorative Finial with Decorative Cap)
All electrical connections and the installation of this fixture must be in agreement with local codes, ordinances or the NEC (National Electric Code) or CEC (Canadian Electrical Code). Do not connect this fixture to an electrical system that does not provide a means for equipment grounding.
Loading...