FIXTURE INSTALLATION GUIDE
Models using B0003D Backplate
(Incandescent Wall Sconce 120V)
B0003D, Rev.3 3-09
CAUTION: Turn off power to electrical box before installing
1. Carefully remove parts from package.
2. Attach the Mounting Bracket (B) to the Outlet Box (C)
with two Machine Screws (D). Thread the Threaded
Nipple (G) into the center of the Mounting Bracket.
Connect the House Ground Wire to the Green
Ground Screw on the Mounting Bracket (F).
3. Connect the electrical leads from the fixture to the
house supply wires, black to black and white to
white, and secure with wirenuts provided (E).
Push the excess wiring into the Outlet Box.
4. With the Backplate oriented with the drainhole
down, align the circular opening on the Backplate
with the Threaded Nipple (G) on the Mounting Bracket.
Push the Backplate over the Threaded Nipple until
the Backplate is flush with the wall, then secure
with the Cap Nut (A) and Star Washer.
F
C
B
NOTE:
Configuration shown is for
instructional purposes only.
Actual Socket Configuration
may vary.
6695 Taylor Rd. Blacklick, OH 43004
D
E
G
www.besalighting.com
A
5. With the power still off, insert bulb of
not more than the labeled wattage.
6. Gently position Glass Diffuser (H) into the Backplate.
Secure with the two retaining screws (I).
Do not overtighten the retaining screws.
7. Restore power.
I
NOTE:
For Model 180 using the optional Decorative Plate, position the Glass Diffuser (H)
into the Decorative Plate and then position the Glass Diffuser/Decorative Plate into
the Backplate. Secure with the two retaining screws (I). DO NOT OVERTIGHTEN.
CAUTION--RISK OF FIRE: Min 75C SUPPLY CONDUCTORS. This fixture requires that the branch
supply wires be rated: MIN 75C. Most dwellings built before 1985 have supply wire rated 60C.
CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR.
H
NOTE:
Glass Diffuser shown is for
example purposes, the actual
Glass Diffuser may be different
in appearance.
All electrical connections and the installation of this fixture must be in agreement with local codes,
ordinances or the NEC (National Electric Code) or CEC (Canadian Electrical Code).
Do not connect this fixture to an electrical system that does not provide a means for equipment grounding.
FIXTURE INSTALLATION GUIDE
Models using B0007D Backplate
(Incandescent Wall Sconce 120V)
B0007D, Rev.3 3-09
CAUTION: Turn off power to electrical box before installing
1. Carefully remove parts from package.
2. Attach the Mounting Bracket (B) to the Outlet Box (C)
with two Machine Screws (D). Thread the Threaded
Nipple (G) into the center of the Mounting Bracket.
Connect the House Ground Wire to the Green Ground
Screw on the Mounting Bracket (F).
3. Connect the electrical leads from the fixture to the
house supply wires, black to black and white to white,
and secure with wirenuts provided (E). Push the
excess wiring into the Outlet Box.
4. With the Backplate oriented with the drainhole down,
align the circular opening on the Backplate with the
Threaded Nipple (G) on the Mounting Bracket. Push
the Backplate over the Threaded Nipple until the
Backplate is flush with the wall, then secure with
the Cap Nut (A) and Star Washer.
D
E
G
F
B
C
NOTE:
Configuration shown is for
instructional purposes only.
Actual Socket Configuration
may vary.
6695 Taylor Rd. Blacklick, OH 43004
www.besalighting.com
A
5. With the power still off, insert bulbs of not more than
the labeled wattage.
6. Gently position Glass Diffuser (H) into the Backplate.
Secure with the four retaining screws (I). Do not
overtighten the retaining screws.
7. Restore power.
I
NOTE:
For Model 181 using the optional Decorative Plate, position the Glass Diffuser (H)
into the Decorative Plate and then position the Glass Diffuser/Decorative Plate into
the Backplate. Secure with the four retaining screws (I). DO NOT OVERTIGHTEN.
CAUTION--RISK OF FIRE: Min 75C SUPPLY CONDUCTORS. This fixture requires that the branch
supply wires be rated: MIN 75C. Most dwellings built before 1985 have supply wire rated 60C.
CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR.
H
NOTE:
Glass Diffuser shown is for example
purposes, the actual Glass Diffuser
may be different in appearance.
All electrical connections and the installation of this fixture must be in agreement with local codes,
ordinances or the NEC (National Electric Code) or CEC (Canadian Electrical Code).
Do not connect this fixture to an electrical system that does not provide a means for equipment grounding.