Bertazzoni REF24FCIPRL, REF36RCPIXL, REF24WCPIXL, REF36RCPIXR, REF36RCPRL Design Guide

...
0 (0)

BUILT-IN REFRIGERATOR COLUMNS BUILT-IN FREEZER COLUMNS BUILT-IN WINE COLUMNS

DESIGN GUIDE

1.0

BUILT-IN COLUMNS

These premium refrigerators, freezers and wine columns are masterpieces of design and technology. Their stylish appearance reflects close attention to detail and high-quality materials, inside and out. The stainless steel front and panel ready doors are mounted with state-of-the-art engineered lift-and-

swing hinges that give the perception of a weightless range of motion. Versatile installation options make it possible to bring together elegant configurations of the refrigerator, freezer and wine columns in any desired width. All three columns work in harmony with handles and finishes available for every Series.

INDEX

INTRODUCTION

3

 

 

BUILT-IN REFRIGERATOR COLUMNS

4

36” Refrigerator Column Panel Installed

6

36” Refrigerator Column Panel Ready

9

30” Refrigerator Column Panel Installed

12

30” Refrigerator Column Panel Ready

15

24” Refrigerator Column Panel Installed

18

24” Refrigerator Column Panel Ready

21

 

 

BUILT-IN FREEZER COLUMNS

24

30” Freezer Column Panel Installed

26

30” Freezer Column Panel Ready

29

24” Freezer Column Panel Installed

32

24” Freezer Column Panel Ready

35

18” Freezer Column Panel Installed

38

18” Freezer Column Panel Ready

41

BUILT-IN WINE COLUMNS

44

24” Wine Column Panel Installed

46

24” Wine Column Panel Ready

49

18” Wine Column Panel Installed

52

18” Wine Column Panel Ready

55

 

 

MULTIPLE INSTALLATIONS

58

42” Double Configurations

61

48” Double Configurations

62

54” Double Configurations

63

60” Double Configurations

64

60” Triple Configurations

65

66” Triple Configurations

66

72” Triple Configurations

67

90” Triple Configurations

68

Custom Door Panel

69

Recommended Installations

70

Refrigeration Handles

71

Toekick Panel

72

bertazzoni.com 3

BUILT-IN REFRIGERATOR COLUMNS

36” - 30” - 24” Panel Ready and Panel Installed

4 bertazzoni.com

BUILT-IN REFRIGERATOR COLUMNS

36” Refrigerator Column Panel Installed

Dimensions

REF36RCPIXL left hinge

REF36RCPIXR right hinge

Handle choices

Professional Series: PROHKCOL

Master series: MASHKCOL

Heritage Series: HERHKCOL

SIDE VIEW

FRONT VIEW

TOP VIEW

22 1/4"

565

80 3/4"

2050

+

5"

1"(25)

127

2 3/4"

70

35 5/8"

904 DOOR WIDTH

77 3/4"

 

83 1/2"

1974

 

 

 

2120

 

 

+

 

 

1"(25)

19 7/8"

5 3/4"

+ 1"(25)

146

505

 

 

*

5 1/2"

35 15/16"

139

913

24 3/8"

620

58 1/2"

1487

100°

SIDE VIEW

FRONT VIEW

TOP VIEW

22 1/4"

565

80 3/4"

2050

+

5"

1"(25)

127

2 3/4"

70

77 3/4"

 

83 1/2"

1974

 

 

 

2120

 

 

+

 

 

1"(25)

19 7/8"

5 3/4"

+ 1"(25)

146

505

 

 

35 5/8"

904 DOOR WIDTH

35 15/16"

5 1/2"

*

913

139

24 3/8"

620

58 1/2"

1487

100°

* Maximum Overall Handle Dimension

For detailed handle dimensions see page 71

6 bertazzoni.com

BUILT-IN REFRIGERATOR COLUMNS

36” Refrigerator Column Panel Installed

Installation requirements

INSTALLATION

All Bertazzoni columns can be installed in a standard 25” depth cutout.

Finish the edges of the opening because they may be visible when the door is open.

For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product.

For instructions of product combinations please see the Multiple Installation Section (page 58).

CABINET REQUIREMENT

Installation of the appliance must be performed in accordance with the provisions of applicable legislation.

Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation.

The floor must be flat and must be capable of supporting the weight of the appliance when in use.

Required floor support

1532 lb (695 kg )

 

 

ELECTRICAL REQUIREMENT

The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed.

Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations.

Placement within the opening may require additional cabinet depth.

TOP VIEW

E

E E

FRONT VIEW

 

 

5"

 

 

 

 

 

 

127

E

E

E

MAX

 

A separate circuit breaker servicing only this appliance is recommended.

Electrical supply

115 V 60 Hz 218 W 2 Amp

 

 

Service

15 Amp dedicated circuit

 

 

Power Connection

NEMA 5 -15P with 79” power cord

 

 

For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.

Dimensions in parentheses are millimeters unless otherwise specified.

bertazzoni.com 7

BUILT-IN REFRIGERATOR COLUMNS

36” Refrigerator Column Panel Installed

Flush installation

TOP VIEWb

25"

635

SIDE VIEW

FRONT VIEW

a

a

 

36"

 

914

83 7/8"

 

2130

 

Min.

 

(a)Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm)

Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.

8 bertazzoni.com

Bertazzoni REF24FCIPRL, REF36RCPIXL, REF24WCPIXL, REF36RCPIXR, REF36RCPRL Design Guide

BUILT-IN REFRIGERATOR COLUMNS

36” Refrigerator Column Panel Ready

Dimensions

REF36RCPRL left hinge

REF36RCPRR right hinge

SIDE VIEW

FRONT VIEW

22 1/4"

565

80 3/4"

2050

+

5"

1"(25)

127

2 3/4"

70

19 7/8" 505

71 1/8"

1808 83 1/2"

2120

+

1"(25)

SIDE VIEW

FRONT VIEW

22 1/4"

565

80 3/4"

2050

+

5"

1"(25)

127

2 3/4"

70

19 7/8" 505

71 1/8"

1808 83 1/2"

2120

+

1"(25)

*Maximum Overall Handle Dimension

**Width of 3/4” (19mm) Door Panel

For detailed handle dimensions see page 71

 

 

TOP VIEW

*

6 1/4"

35 15/16"

 

158

913

24 1/4"

615

**58 5/8"

1489

100°

TOP VIEW

35 15/16"

6 1/4"

*

913

158

 

24 1/4"

615

58 5/8" **

1489

100°

Dimensions in parentheses are millimeters unless otherwise specified.

bertazzoni.com 9

BUILT-IN REFRIGERATOR COLUMNS

36” Refrigerator Column Panel Ready

Installation requirements

INSTALLATION

All Bertazzoni columns can be installed in a standard 25” depth cutout.

Finish the edges of the opening because they may be visible when the door is open.

For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product. For panel ready columns, do not exceed the maximum weight of 75 pounds (34 kg) for door panel. Panel can have thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).

For instructions of product combinations please see the Multiple Installation Section (page 58).

CABINET REQUIREMENT

Installation of the appliance must be performed in accordance with the provisions of applicable legislation.

Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation.

The floor must be flat and must be capable of supporting the weight of the appliance when in use.

Required floor support

1532 lb (695 kg )

 

 

ELECTRICAL REQUIREMENT

The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed.

Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations.

Placement within the opening may require additional cabinet depth.

TOP VIEW

E

E E

FRONT VIEW

 

 

5"

 

 

 

 

 

 

127

E

E

E

MAX

 

A separate circuit breaker servicing only this appliance is recommended.

Electrical supply

115 V 60 Hz 218 W 2 Amp

 

 

Service

15 Amp dedicated circuit

 

 

Power Connection

NEMA 5 -15P with 79” power cord

 

 

For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.

Dimensions in parentheses are millimeters unless otherwise specified.

10 bertazzoni.com

BUILT-IN REFRIGERATOR COLUMNS

36” Refrigerator Column Panel Ready

Flush installation

TOP VIEWb

25"

635

SIDE VIEW

FRONT VIEW

a

a

b

 

 

36"

 

914

83 7/8"

 

2130

 

Min.

 

(a)Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm)

(b)Panel dimensions available on Built-in Food Preservation Design Guide or Installation Manual

Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.

bertazzoni.com 11

BUILT-IN REFRIGERATOR COLUMNS

30” Refrigerator Column Panel Installed

Dimensions

REF30RCPIXL left hinge

REF30RCPIXR right hinge

Handle choices

Professional Series: PROHKCOL

Master series: MASHKCOL

Heritage Series: HERHKCOL

SIDE VIEW

FRONT VIEW

TOP VIEW

22 1/4"

565

80 3/4"

2050

+

5"

1"(25)

127

2 3/4"

70

 

 

29 5/8"

*

4"

29 15/16"

 

 

752

103

761

 

 

DOOR

 

 

 

 

 

WIDTH

 

 

 

 

 

 

 

 

24 3/8"

 

 

 

 

 

620

77 3/4"

 

83 1/2"

52 5/8"

 

1974

 

 

 

 

2120

 

1336

 

 

 

+

 

 

 

 

 

1"(25)

 

 

100°

 

 

 

 

 

19 7/8"

5 3/4"

+ 1"(25)

 

 

 

146

 

 

 

505

 

 

 

 

 

SIDE VIEW

FRONT VIEW

TOP VIEW

22 1/4"

565

80 3/4"

2050

+

5"

1"(25)

127

2 3/4"

70

 

 

29 5/8"

29 15/16"

4"

 

 

752

761

103 *

 

 

DOOR

 

 

 

 

WIDTH

 

 

 

 

 

24 3/8"

 

 

 

 

620

 

77 3/4"

 

83 1/2"

 

 

1974

 

 

52 5/8"

 

 

2120

 

1336

 

 

+

 

 

 

 

1"(25)

100°

 

 

 

 

 

19 7/8"

5 3/4"

+ 1"(25)

 

 

146

 

 

505

 

 

 

 

* Maximum Overall Handle Dimension

For detailed handle dimensions see page 71

Dimensions in parentheses are millimeters unless otherwise specified.

12 bertazzoni.com

BUILT-IN REFRIGERATOR COLUMNS

30” Refrigerator Column Panel Installed

Installation requirements

INSTALLATION

All Bertazzoni columns can be installed in a standard 25” depth cutout.

Finish the edges of the opening because they may be visible when the door is open.

For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product.

For instructions of product combinations please see the Multiple Installation Section (page 58).

CABINET REQUIREMENT

Installation of the appliance must be performed in accordance with the provisions of applicable legislation.

Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation.

The floor must be flat and must be capable of supporting the weight of the appliance when in use.

Required floor support

1257 lb (570 kg )

 

 

ELECTRICAL REQUIREMENT

The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed.

Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations.

Placement within the opening may require additional cabinet depth.

TOP VIEW

E

E E

FRONT VIEW

 

 

5"

 

 

 

 

 

 

127

E

E

E

MAX

 

A separate circuit breaker servicing only this appliance is recommended.

Electrical supply

115 V 60 Hz 218 W 2 Amp

 

 

Service

15 Amp dedicated circuit

 

 

Power Connection

NEMA 5 -15P with 79” power cord

 

 

For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.

Dimensions in parentheses are millimeters unless otherwise specified.

bertazzoni.com 13

BUILT-IN REFRIGERATOR COLUMNS

30” Refrigerator Column Panel Installed

Flush installation

TOP VIEWb

25"

635

SIDE VIEW

FRONT VIEW

a

a

 

30"

 

762

83 7/8"

 

2130

 

Min.

 

(a)Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm)

Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.

14 bertazzoni.com

BUILT-IN REFRIGERATOR COLUMNS

30” Refrigerator Column Panel Ready

Dimensions

REF30RCPRL left hinge

REF30RCPRR right hinge

SIDE VIEW

FRONT VIEW

22 1/4"

565

80 3/4"

2050

+

5"

1"(25)

127

2 3/4"

70

19 7/8" 505

71 1/8"

1808 83 1/2"

2120

+

1"(25)

SIDE VIEW

FRONT VIEW

22 1/4"

565

80 3/4"

2050

+

5"

1"(25)

127

2 3/4"

70

19 7/8" 505

71 1/8"

1808 83 1/2"

2120

+

1"(25)

*Maximum Overall Handle Dimension

**Width of 3/4” (19mm) Door Panel

For detailed handle dimensions see page 71

TOP VIEW

*

5 1/4"

29 15/16"

 

132

761

24 1/4"

615

** 52 5/8" 1338

100°

TOP VIEW

29 15/16"

5 1/4"

*

761

132

 

24 1/4"

615

52 5/8" **

1338

100°

Dimensions in parentheses are millimeters unless otherwise specified.

bertazzoni.com 15

BUILT-IN REFRIGERATOR COLUMNS

30” Refrigerator Column Panel Ready

Installation requirements

INSTALLATION

All Bertazzoni columns can be installed in a standard 25” depth cutout.

Finish the edges of the opening because they may be visible when the door is open.

For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product. For panel ready columns, do not exceed the maximum weight of 75 pounds (34 kg) for door panel. Panel can have thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).

For instructions of product combinations please see the Multiple Installation Section (page 58).

CABINET REQUIREMENT

Installation of the appliance must be performed in accordance with the provisions of applicable legislation.

Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation.

The floor must be flat and must be capable of supporting the weight of the appliance when in use.

Required floor support

1257 lb (570 kg )

 

 

ELECTRICAL REQUIREMENT

The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed.

Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations.

Placement within the opening may require additional cabinet depth.

TOP VIEW

E

E E

FRONT VIEW

 

 

5"

 

 

 

 

 

 

127

E

E

E

MAX

 

A separate circuit breaker servicing only this appliance is recommended.

Electrical supply

115 V 60 Hz 218 W 2 Amp

 

 

Service

15 Amp dedicated circuit

 

 

Power Connection

NEMA 5 -15P with 79” power cord

 

 

For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.

Dimensions in parentheses are millimeters unless otherwise specified.

16 bertazzoni.com

BUILT-IN REFRIGERATOR COLUMNS

30” Refrigerator Column Panel Ready

Flush installation

TOP VIEWb

25"

635

SIDE VIEW

FRONT VIEW

a

a

b

 

 

30"

 

762

83 7/8"

 

2130

 

Min.

 

(a)Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm)

(b)Panel dimensions available on Built-in Food Preservation Design Guide or Installation Manual

Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.

bertazzoni.com 17

BUILT-IN REFRIGERATOR COLUMNS

24” Refrigerator Column Panel Installed

Dimensions

REF24RCPIXL left hinge

REF24RCPIXR right hinge

Handle choices

Professional Series: PROHKCOL

Master series: MASHKCOL

Heritage Series: HERHKCOL

SIDE VIEW

FRONT VIEW

80 3/4"

2050

+

5"

1"(25)

127

2 3/4"

70

22 1/4"

565

23 5/8"

600 DOOR WIDTH

77 3/4"

 

83 1/2"

1974

 

 

 

2120

 

 

+

 

 

1"(25)

19 7/8"

5 3/4"

+ 1"(25)

505

146

TOP VIEW

*

3 1/2"

24"

 

89

609

24 3/8"

620

46 5/8"

1185

100°

SIDE VIEW

FRONT VIEW

80 3/4"

2050

+

5"

1"(25)

127

2 3/4"

70

22 1/4"

565

23 5/8"

600 DOOR WIDTH

77 3/4"

 

83 1/2"

1974

 

 

 

2120

 

 

+

 

 

1"(25)

19 7/8"

5 3/4"

+ 1"(25)

505

146

TOP VIEW

24"

3 1/2"

*

609

89

24 3/8"

620

46 5/8"

1185

100°

* Maximum Overall Handle Dimension

For detailed handle dimensions see page 71

Dimensions in parentheses are millimeters unless otherwise specified.

18 bertazzoni.com

BUILT-IN REFRIGERATOR COLUMNS

24” Refrigerator Column Panel Installed

Installation requirements

INSTALLATION

All Bertazzoni columns can be installed in a standard 25” depth cutout.

Finish the edges of the opening because they may be visible when the door is open.

For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product.

For instructions of product combinations please see the Multiple Installation Section (page 58).

CABINET REQUIREMENT

Installation of the appliance must be performed in accordance with the provisions of applicable legislation.

Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation.

The floor must be flat and must be capable of supporting the weight of the appliance when in use.

Required floor support

992 lb (450 kg )

 

 

ELECTRICAL REQUIREMENT

The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed.

Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations.

Placement within the opening may require additional cabinet depth.

TOP VIEW

E

E E

FRONT VIEW

 

 

5"

 

 

 

 

 

 

127

E

E

E

MAX

 

A separate circuit breaker servicing only this appliance is recommended.

Electrical supply

115 V 60 Hz 163 W 1.5 Amp

 

 

Service

15 Amp dedicated circuit

 

 

Power Connection

NEMA 5 -15P with 79” power cord

 

 

For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.

Dimensions in parentheses are millimeters unless otherwise specified.

bertazzoni.com 19

BUILT-IN REFRIGERATOR COLUMNS

24” Refrigerator Column Panel Installed

Flush installation

TOP VIEWb

25"

635

SIDE VIEW

FRONT VIEW

a

a

 

24"

 

610

83 7/8"

 

2130

 

Min.

 

(a)Area to be left clear for the anti-tipping brackets – 3”1/2x5” (82x127mm)

Dimensions in parentheses are millimeters unless otherwise specified. b: depth includes kitchen cabinet front panel.

20 bertazzoni.com

BUILT-IN REFRIGERATOR COLUMNS

24” Refrigerator Column Panel Ready

Dimensions

REF24RCPRL left hinge

REF24RCPRR right hinge

SIDE VIEW

FRONT VIEW

22 1/4"

565

80 3/4"

2050

+

5"

1"(25)

127

2 3/4"

70

19 7/8" 505

71 1/8"

1808 83 1/2"

2120

+

1"(25)

SIDE VIEW

FRONT VIEW

22 1/4"

565

80 3/4"

2050

+

5"

1"(25)

127

2 3/4"

70

19 7/8" 505

71 1/8"

1808 83 1/2"

2120

+

1"(25)

*Maximum Overall Handle Dimension

**Width of 3/4” (19mm) Door Panel

For detailed handle dimensions see page 71

TOP VIEW

*

4 1/4"

24"

108

609

24 1/4"

615

**

46 3/4"

1187

100°

TOP VIEW

24"

4 1/4"

*

609

108

 

24 1/4"

615

46 3/4" **

1187

100°

Dimensions in parentheses are millimeters unless otherwise specified.

bertazzoni.com 21

BUILT-IN REFRIGERATOR COLUMNS

24” Refrigerator Column Panel Ready

Installation requirements

INSTALLATION

All Bertazzoni columns can be installed in a standard 25” depth cutout.

Finish the edges of the opening because they may be visible when the door is open.

For a built-in installation, to cover gaps between the appliance and the adjacent cabinets, special side profiles are factoryinstalled and covering frames are provided with the product. For panel ready columns, do not exceed the maximum weight of 75 pounds (34 kg) for door panel. Panel can have thickness ranging between ¾” (18 mm) and 1 1/8” (28 mm).

For instructions of product combinations please see the Multiple Installation Section (page 58).

CABINET REQUIREMENT

Installation of the appliance must be performed in accordance with the provisions of applicable legislation.

Be sure that support of this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation.

The floor must be flat and must be capable of supporting the weight of the appliance when in use.

Required floor support

992 lb (450 kg )

 

 

ELECTRICAL REQUIREMENT

The installation must comply with all applicable electrical codes. A properly - grounded horizontally - mounted electrical receptacle should be installed.

Place the electrical supply flush with the back wall and within the shaded area shown in the illustrations.

Placement within the opening may require additional cabinet depth.

TOP VIEW

E

E E

FRONT VIEW

 

 

5"

 

 

 

 

 

 

127

E

E

E

MAX

 

A separate circuit breaker servicing only this appliance is recommended.

Electrical supply

115 V 60 Hz 163 W 1.5 Amp

 

 

Service

15 Amp dedicated circuit

 

 

Power Connection

NEMA 5 -15P with 79” power cord

 

 

For detailed installation specifications consult the multiple installation requirements page or each single product installation manual.

Dimensions in parentheses are millimeters unless otherwise specified.

22 bertazzoni.com

Loading...
+ 51 hidden pages