Technical Data
Capacitive Proximity Switch
S
eries M18
Description KCN-T18PS/013-KLPS12V Article number 6507921004
Wiring Diagram
1
C
4
3
+
–
Identifying characteristics in accordance with EN 60947-5-2
Electrical data
Rated operating distance S
Effective operating distance S
20 mm
n
12,15 ... 14,85 mm
r
Mounting non flush
Standard target 50 mm x 50 mm x 1 mm; material: steel; connected to earth
Sensing range S
Assured operating distance S
11,5 ... 12,5 mm; Sr adjustable with potentiometer (POT);
d
turn right ≙ high sensitivity, turn left ≙ low sensitivity
0 ≤ Sa ≤ 0,8 x Sr
a
Switching element function DC N.O. pnp-output
Repeat accuracy R ≤ 0,1 x Sr
Differential travel (hysteresis) H ≤ 0,2 x Sr
Frequency of operating cycles f ≥ 25 Hz
Rate doperational voltage U
Operational voltage range U
Rated insulation voltage U
Rated impulse withstand voltage U
Voltage drop U
e
B
i
imp
d
12 V - 48 V DC
10 V - 60 V DC
75 V DC
500 V
< 2 V DC
Utilization category DC 13
Rated operational current l
Minimum operational current I
Off–state current l
No–load supply current l
e
m
r
o
200 mA DC
≥ 1 mA DC
≤ 0,5 mA DC
≤ 20 mA DC
Switching element permanent overload and s.c.p.
Short–circuit protection pulsed
False polarity protection yes, with permutation of +, –, output no damage occurs
Time delay before availability
t
≤ 50 ms
v
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2015-07-21 and will not be removed in case of changes.
Page 1 of 2
6507921004 / 0297-15
Technical Data
Electromagnetic compatibility (EMC)
Electromagnetic field test IEC 61000-4-3 10 V/m, 80...1000 MHz
Electrostatic discharge test IEC 61000-4-2 6 kV CD, 8 kV AD
Electrical fast transient immunity test (Burst) IEC 61000-4-4 4 kV coupling clamp
Impulse voltage withstand ability (Surge) IEC 61000-4-5 500 V, 1,2/50 μs @ Ri = 42 Ω
Mechanical Data
Enclosure PBT, black
End cap PA6.6, black
Ambient air temperature -25 °C ... +70 °C
Type of protection IP65 (only in fully locked position with it’s plugs)
Pollution degree 3 (Pollution of the active zone can cause impairments of the operating distances.)
Indication
Termination type plug-connection
For attachment 2 x Hexagon nut (PA6.6, black)
EU Conformity
Power ON = LED green
Output ON = LED yellow
acc. to directive 2004 / 108 / EC
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2015-07-21 and will not be removed in case of changes.
Page 2 of 2
6507921004 / 0297-15