Technical Data
Mechanical data
Enclosure PA6 (glass fibre reinforced)
Cover PA6 (glass fibre reinforced)
Actuator Lever arm housing (Zn-DG), Lever (st), Roller (thermoplastic)
Ambient air temperature -25 °C … +70 °C (cable in fixed position)
Contact type Snap action, 1 NO, 1 NC (Zb)
Mechanical life 3 x 10
Switching frequency ≤ 30 / min.
Assembly 2 x M4 or 2 x M5
Connection Cable 4 x 0,75 mm²
Weight ≈ 0,20 kg
Installation position operator definable
Protection type IP67 acc. to IEC/EN 60529; DIN VDE 0470 T1
Actuation
Operating direction: from 2 sides
The actuating head can be turned in steps of 90° by lifting the clamp. This means that it can be approached from
8 different directions.
6
switching cycles
ID for safety engineering
B10d 6 x 106 cycles
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
DIN EN ISO 13849-1
EU Conformity
acc. to directive 2006/42/EC
Approvals
CSAUS A300, Q300
C
Notes
The indicated protection class (IP-code) is only valid when the actuator is correctly mounted.
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2016-06-30 and will not be removed in case of changes.
Page 2 of 2
6189185005 / 2355-16