Technical Data
Mechanical data
Enclosure Die-cast aluminium
Cover Sheet aluminium
Actuator Lever arm housing (Zn-die cast), lever (st), roller (thermoplastic)
Ambient air temperature -30° C ... +80° C
Contact type 1 NC, 1NO (Zb)
Mechanical life 10 x 10
Switching frequency ≤ 100 / min.
Assembly 4 x M5
Connection 4 screw connections (M3,5)
Conductor cross-sections
Cable entrance 1 x M20 x 1,5
Weight ≈ 0,30 kg
Installation position operator definable
Protection type IP65 acc. to IEC/EN 60529
Actuation
6
operating cycles
Solid: 0,5 ... 1,5 mm² or
Litz wire with ferrules: 0,5 ... 1,5 mm²
The actuating device is preferably started from 2 sides.
By loosening the 4 screws the actuation assembly can be rotated in 90 degree increments such that 8 actuation
directions are possible. The actuation assembly is to be again fastened to the housing using the 4 screws.
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EU Conformity
acc. to directive 2014/35/EU (Low-Voltage-Directive)
Approvals
CSAUS A300 (same polarity)
C
CCC
Notes
The degree of protection specified (IP code) applies only to a properly closed cover and the use of an equivalent
cable gland.
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2017-04-11 and will not be removed in case of changes.
Page 2 of 2
6187386041 / 2224-17