Technical Data
Metal Switches
Series ENM 2
Description
ENM2-U1Z AHSGU V8 90GR
Article number
Operating symbol
Operating diagram
ON OFF
Tolerances
Operating point: ± 3,5 °;
Operating torque: ± 10 %
Electrical data
Rated insulation voltage U
Conv. thermal current I
Rated operational voltage U
400 V AC
i
10 A
the
240 V AC
e
Utilization category AC-15, Ue /Ie 240 V / 3 A
Direct opening action acc. to IEC/EN 60947-5-1, Annex K
Short-circuit protective device Fuse 10 A gL/gG
Safety class
I
6187135103
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of he actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Document: 6187135103_en.doc / Last update: 1 / 2262-09
Date of issue: 29.06.2009 / Page 1 of 2
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany / www.bernstein.eu
Vorlage : 0850174282 Orig. 1