Technical Data
Mechanical data
Enclosure Thermoplastic, glass fibre reinforced (UL 94-V0)
Cover Thermoplastic, glass fibre reinforced (UL 94-V0)
Actuator Turret head (Zn-die cast), lever (st), roller (thermoplastic)
Ambient air temperature -30 °C ... +80 °C
Contact type 1 NC, 1NO (Zb)
Mechanical life 10 x 10
Switching frequency ≤ 100 / min.
Assembly 2 x M4
Connection 4 screw connections (M3,5)
Conductor cross-sections
Cable entrance 1 x cable gland M20 x 1,5 (clamping range 5 – 10 mm),
Weight ≈ 0,24 kg
Installation position operator definable
Protection type IP65 acc. to IEC/EN 60529
Actuation
The actuating device is preferably started from 2 sides.
By loosening the 4 screws the actuation assembly can be rotated in 90 degree increments such that 8 actuation directions are
possible.
The actuation assembly is to be again fastened to the housing using the 4 screws.
6
operating cycles
Solid: 0,5 ... 1,5 mm² or
Litz wire with ferrules: 0,5 ... 1,5 mm²
ID for safety engineering
B10d 20 x 106 cycles
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
DIN EN ISO 13849-1
EU Conformity
acc. to directive 2014/35/EU (Low-Voltage-Directive)
Approvals
A300 (same polarity)
CSA
C
US
Notes
The specified protection classification (IP code) applies only when the cover is closed and the appropriate cable
is used, in accordance with the clamping range of the above mentioned cable gland.
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2017-04-10 and will not be removed in case of changes.
Page 2 of 2
6181135096 / 2222-17