Bernstein 613.3817.030 Technical Data

Technical Data
Metal Switches
Series SN2
Description
SN2-E2 RIW 90GR
Article number
Operating symbol
Operating diagram
ON OFF
Tolerances Operating point: ± 0,25 mm;
Electrical data
Rated insulation voltage U Conv. thermal current I Rated operational voltage U
250 V AC
i
5 A
the
240 V
e
Utilization category AC-15, Ue /Ie 240 V /1,5 A Short-circuit protective device Fuse 6 A gG Protection class
I
6133817030
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice!
Document: 6133817030_en / Last update: 1 / 2727-12
Date of issue: 29.10.2012 / Page 1 of 2
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany / www.bernstein.eu
Technical Data
Metal Switches
Mechanical data
Enclosure Die-cast aluminium Cover Sheet aluminium Actuator Roller, St Ambient air temperature -30 °C ... +80 °C Contact type 2 NO (Zb) Mechanical life 1 x 106 operating cycles Switching frequency 100 / min. Assembly 4 x M5 Connection 4 screw terminals (M3,5) Conductor cross-sections Solid: 0,5 ... 1,5 mm² Litz wire with ferrules: 0,5 ... 1,5 mm² Cable entrance 3 x M20x1,5 Weight 0,2 kg Installation position operator definable Protection type IP65 acc. to IEC/EN 60529
Actuation
By loosening the 4 screws the actuation assembly can be rotated in 90 degree increments such that 2 actuation directions are possible. The actuation assembly is to be again fastened to the housing using the 4 screws.
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1 VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EU Conformity
acc. to directive 2006 / 95 / EC
Notes
The degree of protection specified (IP65) applies only to a properly closed cover and the use of an equivalent cable gland with adequate cable and fitted inserts. Unused threaded holes are to be permanently closed with appropriate fitted inserts (e.g.: blanking plugs).
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice!
Document: 6133817030_en / Last update: 1 / 2727-12
Date of issue: 29.10.2012 / Page 2 of 2
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany / www.bernstein.eu