Technical Data
Metal Switches
Series GC
Description
GC-U1Z VT 90GR K-RAST
Article number
Operating symbol
Operating diagram
Actuator
withdraw
Latching
Latching
Blind hole for
fitting pin
Actuator
inserted
ON OFF
Tolerances
Operating point: ± 0,3mm;
Operating torque: ± 10%
Built in dimension
Electrical data
Rated insulation voltage U
Conv. thermal current I
Utilization category AC-15, U
400 VAC
i
10A
the
e /Ie
240V/3A
Positive opening NC contact acc. to IEC/EN 60947-5-1, Annex K
Short-circuit protective device Fuse 10A gL/gG
Protection class
I
6122100724
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of he actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Document: 6122100724_en.doc / Last update: 1 / 2046-08
Date of issue: 08.02.2008 / Page 1 of 2
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany / www.bernstein-ag.de
Vorlage : 0850174282 Orig. 1
Technical Data
Metal Switches
Mechanical data
Enclosure Die-cast aluminium
Cover Sheet aluminium
Actuator Separate actuator
Latching Forced disconnection and latching of normally closed
contacts ( 11 – 12 )
Ambient air temperature -30°C ... +80°C
Contact type 1 NC, 1 NO (Zb)
Mechanical life 1 x 106 operating cycles
Switching frequency ≤ 10 / min.
Assembly 2 x M4
Connection 4 screw terminals (M3,5)
Conductor cross-sections Solid: 0.5 ... 1.5mm²
Litz wire with ferrules: 0.5 ... 1.5mm²
Cable entrance 1 x cable gland
(M20x1,5; clamp-range 6 – 12mm),
Weight ≈ 0,37 kg
Installation position Operator definable
Protection type IP65 acc. to IEC/EN 60529
Standards
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EU Conformity
Notes
The specified protection classification (IP code) applies only when the cover is closed and the appropriate cable
is used, in accordance with the clamping range of the above mentioned cable gland.
Mounting:
When used as safety switch pay attention to EN 60204 (use NC-contacts).
Also secure by a set pin (hole within the bottom of the case).
Actuator to be fixed with 4 screws M4 at the movable guard.
Please pay attention to the specified maximum of misalignment of the actuator.
Position of the actuator head determined at works, must not be modified.
Screws obviously secured.
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of he actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Document: 6122100724_en.doc / Last update: 1 / 2046-08
Date of issue: 08.02.2008 / Page 2 of 2
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany / www.bernstein-ag.de
Vorlage : 0850174282 Orig. 1