Bernstein 612.2100.724 Technical Data

Technical Data
Metal Switches
Series GC
Description
GC-U1Z VT 90GR K-RAST
Article number
Operating symbol
Operating diagram
Actuator withdraw
Latching
Latching
Blind hole for fitting pin
Actuator inserted
ON OFF
Tolerances Operating point: ± 0,3mm; Operating torque: ± 10%
Built in dimension
Electrical data
Rated insulation voltage U Conv. thermal current I Utilization category AC-15, U
400 VAC
i
10A
the
e /Ie
240V/3A Positive opening NC contact acc. to IEC/EN 60947-5-1, Annex K Short-circuit protective device Fuse 10A gL/gG Protection class
I
6122100724
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of he actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice!
Document: 6122100724_en.doc / Last update: 1 / 2046-08
Date of issue: 08.02.2008 / Page 1 of 2
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany / www.bernstein-ag.de
Technical Data
Metal Switches
Mechanical data
Enclosure Die-cast aluminium Cover Sheet aluminium Actuator Separate actuator Latching Forced disconnection and latching of normally closed contacts ( 11 – 12 ) Ambient air temperature -30°C ... +80°C Contact type 1 NC, 1 NO (Zb) Mechanical life 1 x 106 operating cycles Switching frequency 10 / min. Assembly 2 x M4 Connection 4 screw terminals (M3,5) Conductor cross-sections Solid: 0.5 ... 1.5mm² Litz wire with ferrules: 0.5 ... 1.5mm² Cable entrance 1 x cable gland (M20x1,5; clamp-range 6 – 12mm), Weight 0,37 kg Installation position Operator definable Protection type IP65 acc. to IEC/EN 60529
Standards
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EU Conformity
Notes
The specified protection classification (IP code) applies only when the cover is closed and the appropriate cable is used, in accordance with the clamping range of the above mentioned cable gland.
Mounting: When used as safety switch pay attention to EN 60204 (use NC-contacts). Also secure by a set pin (hole within the bottom of the case). Actuator to be fixed with 4 screws M4 at the movable guard. Please pay attention to the specified maximum of misalignment of the actuator.
Position of the actuator head determined at works, must not be modified. Screws obviously secured.
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of he actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice!
Document: 6122100724_en.doc / Last update: 1 / 2046-08
Date of issue: 08.02.2008 / Page 2 of 2
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany / www.bernstein-ag.de