Technical Data
Metal bodied limit switch
Series GC
Description GC-A2Z VKW Article number 6121800940
Operating symbol
Operating diagram
Blind hole for fitting pin
Ø4; 5.5 deep
Tolerance:
Operating Point ± 3,5 °;
On Off
Operating torque ± 10 %
Electrical Data
Rated insulation voltage U
Conv. thermal current I
Rated operational voltage U
Utilization category AC-15, U
Positive opening NC contact
250 V AC
i
6 A
the
240 V
e
p
acc. to IEC/EN 60947-5-1, Annex K
240 V / 1,5 A
e/Ie
Short-circuit protective device Fuse 6 A gG
Protection class
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2016-11-22 and will not be removed in case of changes.
I
Page 1 of 2
6121800940 / 2669-16
Technical Data
Mechanical data
Enclosure Die-cast aluminium
Cover Sheet aluminium
Actuator Lever (steel)
Ambient air temperature -30° C ... +80° C
Contact type 2 NC (Zb)
Mechanical life 1 x 10
Switching frequency ≤ 20 / min.
Assembly 2 x M4
Connection 4 screw connections (M3,5)
Conductor cross-sections Solid: 0,5 ... 1,5 mm² or
Cable entrance 1 x M20 x 1,5
Weight ≈ 0,19 kg
Installation position operator definable
Protection type IP20 acc. to IEC/EN 60529
ID for safety engineering
B10d 2 x 10
6
operating cycles
Litz wire with ferrules: 0,5 ... 1,5 mm²
6
cycles
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
DIN EN ISO 13849-1
EU Conformity
acc. to directive 2014/35/EU
Notes
The degree of protection specified (IP code) applies only to a properly closed cover and the use of an equivalent
cable gland with adequate cable.
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2016-11-22 and will not be removed in case of changes.
Page 2 of 2
6121800940 / 2669-16