Bernstein 612.1385.974 Technical Data

Technical Data
Metal Switches
Series GC
GC-SU1Z AHS
Article number
Operating symbol
Operating diagram
ON OFF
Tolerances Operating point: ± 3,5°; Actuating force: ± 10%
Electrical data
Rated insulation voltage U Conv. thermal current I Rated operational voltage U
i
the
e
400 V AC 10 A
240 V Utilization category AC-15, Ue /Ie 240 V / 3 A Direct opening action acc. to IEC/EN 60947-5-1, Annex K Short-circuit protective device Fuse 2 A gG Protection class
I
6121385974
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice!
Document: 6121385974_en / Last update: 1 / 2393-11
Date of issue: 11.08.2011 / Page 1 of 2
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany / www.bernstein.eu
Vorlage : 0850174282 Orig. 1
Technical Data
Metal Switches
Mechanical data
Enclosure Die-cast aluminium Cover Sheet aluminium Actuator Turret head (zinc die cast) roller (thermoplastic) Ambient air temperature -30 °C ... +80 °C Contact type 1 NC, 1 NO (Zb) Mechanical life 107 operating cycles Switching frequency 100 / min. Assembly 2 x M4 Connection 4 screw terminals (M3,5) Conductor cross-sections Solid: 0,5 ... 1,5 mm² Litz wire with ferrules: 0,5 ... 1,5 mm² Cable entrance M20 x 1,5 Weight 0,2 kg Installation position Operator definable Protection type IP65 acc. to IEC/EN 60529
Actuation
By loosening the 4 screws the actuation assembly can be rotated in 90 degree increments such that 4 actuation directions are possible. The actuation assembly is to be again fastened to the housing using the 4 screws.
Standards
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EU Conformity
Notes
The degree of protection specified (IP code) applies only to a properly closed cover and the use of an equivalent cable gland with adequate cable.
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
acc. to directive 2006/95/EG
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice!
Document: 6121385974_en / Last update: 1 / 2393-11
Date of issue: 11.08.2011 / Page 2 of 2
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany / www.bernstein.eu
Vorlage : 0850174282 Orig. 1