Technical Data
Metal Switches
Series GC
Description
GC-PNP AHST
Article number
6121385805
Wiring Diagram
Actuatin
(Inductive Proximity Switch)
I
1
2
4
3
+
-
4
2
3
1
Electrical data (Inductive Proximity Switch)
Rated operational voltage Ue 12 - 48V DC
Operational voltage range UB 10 - 60V DC
Rated insulation voltage Ui 75V DC
Rated impulse withstand voltage U
Voltage drop Ud ≤ 2V
Utilization category DC-13
Rated operational current le 300mA @ 70°C, 400mA @ 20°C
Minimum operational current Im ≤1mA
Off–state current lr < 0,1mA
No–load supply current lo < 8,1mA
Rated conditional short–circuit current 100A
Switching element PNP Transistor
Short–circuit protection pulsed
Rated supply frequency DC
False polarity protection protection against reverse supply polarity
500V
imp
Electromagnetic compatibility (EMC) (Inductive Proximity Switch)
Electromagnetic field test IEC 61000-4-3
Electrostatic discharge test IEC 61000-4-2
Electrical fast transient immunity test (Burst) IEC 61000-4-4
Impulse voltage withstand ability (Surge) IEC 255-5
Radiated disturbance field strength EN 55011
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for
defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to
change without notice!
Document: 6121385805_en / : 1 / Last update: 3021-05
Date of issue: 06.12.2005 / Page 1 of 2
Bernstein AG, Tieloser W eg 6, D-32457 Porta Westfalica, Germany / www.bernstein-ag.de
Vorlage : 0850174282 Orig. 1
Technical Data
Metal Switches
Mechanical data
Enclosure Die-cast aluminium
Cover plate aluminium
Actuator Lever arm housing (Zn-DG), lever and roller (St)
Operating point preset 40° ±5%
adjustable range 30° ... 45°
Operating torque 10Ncm
Ambient air temperature -25°C ... +70°C
Mechanical life 10 x 106 operating cycles
≤
Switching frequency
Assembly 2 x M4
Connection 4 screw terminals (M3.5)
Conductor cross-sections Solid: 0.5 ... 1.5mm²
Litz wire with ferrules: 0.5 ... 1.5mm²
Cable entrance 1 x M20x1.5
Weight
Installation position Operator definable
Protection type IP65 acc. to IEC/EN 60529
Actuation
By loosening the 4 screws the actuation assembly can be rotated in 90 degree increments such that 4 actuation
directions are possible. The actuation assembly is to be again fastened to the housing using the 4 screws.
Standards
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
VDE 0660 T208, DIN EN 60947-5-2, IEC 60947-5-2
EU Conformity
Notes
The degree of protection specified (IP code) applies only to a properly closed cover and the use of an equivalent
cable gland with adequate cable.
100 / min.
≈
0,22 kg
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for
defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to
change without notice!
Date of issue: 06.12.2005 / Page 2 of 2
Document: 6121385805_en / : 1 / Last update: 3021-05
Bernstein AG, Tieloser W eg 6, D-32457 Porta Westfalica, Germany / www.bernstein-ag.de
Vorlage : 0850174282 Orig. 1