Bernstein 612.1377.849 Technical Data

Metal bodied limit switch
Series GC
Description GC-SU1Z KNW 180GR Article number 6121377849
Operating symbol
Operating diagram
Tolerance: Operating point ±0,25 mm;
On Off
Actuating force ±10 %
Electrical Data
Rated insulation voltage U Conv. thermal current I Rated operational voltage U
Utilization category
Positive opening NC contact
400 V AC
i
10 A
the
240 V
e
AC-15, Ue/Ie 240 V / 3 A DC-13, Ue/Ie 24 V / 4 A
acc. to IEC/EN 60947-5-1, Annex K Short-circuit protective device Fuse 2 A gG Protection class
I
Blind hole for fitting pin
Sackloch für Passstift
Ø4; 5.5 deep
Ø4; 5,5 tief
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2017-07-17 and will not be removed in case of changes.
Page 1 of 2
6121377849 / 2489-17
Mechanical data
Enclosure Die-cast aluminium Cover Sheet aluminium Actuator Lever (st-plate), roller (thermoplastic) Ambient air temperature -30 °C ... +80 °C Contact type 1 NC, 1 NO (Zb) Mechanical life 10 x 10 Switching frequency ≤ 100 / min. Assembly 2 x M5 Connection 4 screw connections (M3,5)
Conductor cross-sections
Cable entrance 1 x M20 x 1,5 Weight ≈ 0,16 kg Installation position operator definable Protection type IP65 acc. to IEC/EN 60529
ID for safety engineering
B10d 20 x 10
6
operating cycles
Solid: 0,5 ... 1,5 mm² or Litz wire with ferrules: 0,5 ... 1,5 mm²
6
cycles
Actuation
By loosening the 4 screws the actuation assembly can be rotated in 90 degree increments such that 4 actuation directions are possible. The actuation assembly is to be again fastened to the housing using the 4 screws.
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1 VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1 DIN EN ISO 13849-1
EU Conformity
acc. to directive 2014/35/EU (Low-Voltage-Directive)
Approvals
CSAUS A300 (same polarity ; AC-15, Ue/Ie 240 V / 3 A)
C
CCC
Notes
The switch must not be used as a stop. The degree of protection specified (IP code) applies only to a properly closed cover and the use of an equivalent cable gland with adequate cable.
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2017-07-17 and will not be removed in case of changes.
Page 2 of 2
6121377849 / 2489-17