Technical Data
Metal bodied limit switch
Series GC
Description GC-SU1 RIW 90GR HITZE Article number 6121167462
Operating symbol
Operating diagram
Tolerance:
Operating Point ± 0,25 mm;
On Off
Operating force ± 10 %
Electrical Data
Rated insulation voltage U
Conv. thermal current I
Rated operational voltage U
Utilization category AC-15, U
250 V AC
i
6 A
the
240 V
e
e/Ie
Short-circuit protective device Fuse 2 A gG
Protection class
I
Blind hole for fitting pin
Ø4; 5.5 deep
240 V / 3 A
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2017-08-23 and will not be removed in case of changes.
Page 1 of 2
6121167462 / 2443-17
Technical Data
Mechanical data
Enclosure Die-cast aluminium
Cover Sheet aluminium
Actuator St-roller
Ambient air temperature -30 °C ... +100 °C
Contact type 1 NC, 1 NO
Mechanical life 10 x 10
Switching frequency ≤ 100 / min.
Assembly 2 x M4
Connection 4 screw connections (M3)
Conductor cross-sections
Cable entrance 1 x cable gland (M20x1.5) (clamp-range 5,5 – 6,1mm)
Weight ≈ 0,16 kg
Installation position operator definable
Protection type IP65
Actuation
By loosening the 4 screws the actuation assembly can be rotated in 90 degree increments such that 4 actuation
directions are possible. The actuation assembly is to be again fastened to the housing using the 4 screws.
6
operating cycles
Solid: 0,5 ... 1,5 mm² or
Litz wire with ferrules: 0,5 ... 1,5 mm²
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EU Conformity
acc. to directive 2014/35/EU (Low-Voltage-Directive)
Approvals
CCC
Notes
The specified protection classification (IP code) applies only when the cover is closed and the appropriate cable
is used, in accordance with the clamping range of the above mentioned cable gland.
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2017-08-23 and will not be removed in case of changes.
Page 2 of 2
6121167462 / 2443-17