Bernstein 611.6819.140 Technical Data

Electrical data
Type 1 switches
Slow-action contact C2 / Ti2 IF I88
Switching function
Switching contacts
Designation U
I
i
Utilization category Short-circuit protection
Normally-closed contact 2NC A2Z 250 V 10 A AC-15 Ue/Ie 240 V/3 A Fuse 6 A gL/gG 3 x 10 Changeover contact 1NC/1S U1Z 250 V 10 A AC-15 Ue/Ie 240 V/3 A Fuse 6 A gL/gG 3 x 10
Changeover contact, overlapping
1NC/1S UV1Z 250 V 10 A AC-15 U
Normally-open contact 2S E2 250 V 10 A AC-15 Ue/Ie 240 V/3 A Fuse 6 A gL/gG 3 x 10
Snap-action contact C2 / Ti2 IF I88
Switching function
Normally-closed contact 2NC SA2Z 250 V 10 A AC-15 Ue/Ie 240 V/3 A Fuse 6 A gL/gG 3 x 10 Changeover contact 1NC/1S SU1Z 250 V 10 A AC-15 Ue/Ie 240 V/3 A Fuse 6 A gL/gG 3 x 10 Normally-open contact 2S SE2 250 V 10 A AC-15 Ue/Ie 240 V/3 A Fuse 6 A gL/gG 3 x 10
Switching contacts
Designation U
I
i
Utilization category Short-circuit protection
Slow-action contact Bi2 ENK
Switching function
Normally-closed contact 2NC A2Z 400 V 10 A AC-15 Ue/Ie 240 V/3 A Fuse 6 A gL/gG 1 x 10 Changeover contact 1NC / 1NO U1Z 400 V 10 A AC-15 Ue/Ie 240 V/3 A Fuse 10 A gL/gG 10 x 10
Changeover contact, overlapping
Normally-open contact 2S E2
Switching contacts
Designation U
I
i
Utilization category Short-circuit protection
1NC / 1NO UV1Z 400 V 10 A AC-15 Ue/Ie 240 V/3 A Fuse 10 A gL/gG 10 x 10
Mechanical service life
6
6
6
Mechanical service life
6
6
6
Mechanical service life
6
6
6
B10d U
I
i
6 mill. 250 V 10 A AC-15 U 6 mill. 250 V 10 A AC-15 U
250 V 5 A AC-15 U
B10d U
I
i
6 mill. 250 V 10 A AC-15 U 6 mill. 250 V 10 A AC-15 U
B10d U
I
i
2 mill. 400 V 5 A AC-15 U 20 mill. 400 V 10 A AC-15 U 20 mill. 400 V 10 A AC-15 U
Snap-action contact Bi2 ENK
Switching function
Switching contacts
Designation U
I
i
Utilization category Short-circuit protection
Normally-closed contact 2NC SA2Z Changeover contact 1NC / NO SU1Z 400 V 10 A AC-15 Ue/Ie 240 V/3 A Fuse 2 A gL/gG 10 x 10 Normally-open contact 2S SE2
Mechanical service life
6
B10d U
I
i
20 mill. 400 V 10 A AC-15 U
Slow-action contact GC SN2 ENM2
Switching function
Switching contacts
Designation U
I
i
Utilization category Short-circuit protection
Normally-closed contact 2NC A2Z 400 V 6 A Fuse 6 A gL/gG 1 x 10 Changeover contact 1NC / 1NO U1Z 400 V 10 A AC-15 Ue/Ie 240 V/3 A Fuse 10 A gL/gG 10 x 10
Changeover contact, overlapping
1NC / 1NO UV1Z 400 V 10 A AC-15 Ue/Ie 240 V/3 A Fuse 10 A gL/gG 10 x 10
Normally-open contact 2S E2 400 V 6 A Fuse 6 A gL/gG 3 x 10
6021820175 GC-A2 HIW = 20 million  60121100622 GC-U1Z VKS, 6121100623 GC-U1Z VKW = 2 million *6087135013 ENM2-U1Z AHS-V, 6087135030 ENM2-U1Z AHZ = 2 million
Mechanical service life
5
6
6
6
B10d U
I
i
0,2 mill.400 V 10 A AC-15 U 20 mill.400 V 10 A AC-15 U 20 mill. – 400 V 10 A AC-15 U 250 V 10 A AC-15 U
Snap-action contact GC SN2 ENM2
Switching function
Switching contacts
Designation U
I
i
Utilization category Short-circuit protection
Normally-closed contact 2NC SA2Z 250 V 10 A AC-15 U Changeover contact 1NC / 1NO SU1Z 400 V 10 A AC-15 Ue/Ie 240 V/3 A Fuse 2 A gL/gG 10 x 10 Normally-open contact 2S SE2 250 V 10 A AC-15 U
Mechanical service life
6
B10d U
I
i
20 mill. 400 V 10 A AC-15 U
70
Utilization category Short-circuit protection
240 V/3 A Fuse 6 A gL/gG 3 x 10
e/Ie
240 V/3 A Fuse 6 A gL/gG 3 x 10
e/Ie
Mechanical service life
6
6
B10d U
I
i
Utilization category Short-circuit protection
Mechanical service life
6 mill. 250 V 5 A AC-15 Ue/Ie 240 V/1.5 A Fuse 6 A gL/gG 1 x 10 6 mill. 250 V 10 A AC-15 Ue/Ie 240 V/3 A Fuse 10 A gL/gG 10 x 10
240 V/3 A Fuse 10 A gL/gG 10 x 10
e/Ie
240 V/1.5 A Fuse 6 A gL/gG 1 x 10
e/Ie
*6116819140 I88-U1Z KS, 6186103005 I88-U1Z W RAST = 2 million
B10d
6
2 mill.
6
20 mill.*
6
20 mill.
6
Utilization category Short-circuit protection
240 V/3 A Fuse 6 A gL/gG 3 x 10
e/Ie
240 V/3 A Fuse 6 A gL/gG 3 x 10
e/Ie
Utilization category Short-circuit protection
240 V/1.5 A Fuse 6 A gL/gG 1 x 10
e/Ie
240 V/3 A Fuse 10 A gL/gG 10 x 10
e/Ie
240 V/3 A Fuse 10 A gL/gG 10 x 10
e/Ie
*6181135251 ENK-U1Z AHSGU RAST RO50 = 2 million
Utilization category Short-circuit protection
240 V/3 A Fuse 2 A gL/gG 10 x 10
e/Ie
Mechanical service life
6
6
Mechanical service life
6
6
6
Mechanical service life
6
B10d U
I
i
Utilization category Short-circuit protection
6 mill. – 6 mill. 250 V 10 A AC-15 Ue/Ie 240 V/3 A Fuse 2 A gL/gG 10 x 10
Mechanical service life
6
B10d
2 mill. 20 mill.* 20 mill.
B10d
20 mill.
B10d
20 mill.
Utilization category Short-circuit protection
240 V/3 A Fuse 6 A gL/gG 10 x 10
e/Ie
240 V/3 A Fuse 10 A gL/gG 20 mill. 400 V 10 A AC-15 Ue/Ie 240 V/3 A Fuse 10 A gL/gG 10 x 10
e/Ie
Utilization category Short-circuit protection
240 V/3 A Fuse 2 A gL/gG 10 x 10
e/Ie
Mechanical service life
6
Mechanical service life
6
B10d U
I
i
Utilization category Short-circuit protection
Mechanical service life
20 mill. 250 V 10 A AC-15 Ue/Ie 240 V/3 A Fuse 6 A gL/gG 1 x 10
240 V/3 A Fuse 10 A gL/gG 10 x 10
e/Ie
240 V/3 A Fuse 10 A gL/gG 10 x 10
e/Ie
B10d U
I
i
Utilization category Short-circuit protection
240 V/3 A Fuse 6 A gL/gG 3 x 10
e/Ie
Mechanical service life
20 mill. 400 V 10 A AC-15 Ue/Ie 240 V/3 A Fuse 2 A gL/gG 10 x 10
240 V/3 A Fuse 6 A gL/gG 3 x 10
e/Ie
B10d
6
2 mill.
6
20 mill.*
6
20 mill.
6
B10d
6
6 mill.
6
20 mill.
6
71