Bernstein 608.8171.054 Technical Data

Plastic bodied limit switch
Series TI2
Description TI2-SU1Z HW RO13,5 Article number 6088171054
Operating symbol
Fixed positioning with
e.g. fixing screw M5
according to the standard
DINENISO4762.
Operating diagram
0 mm
0.9
2.3
3.8
5.5 mm
Tolerance: Operating point ± 0,25 mm;
On Off
Actuating force ± 10 %
Electrical Data
Rated insulation voltage U Conv. thermal current I Rated operational voltage U
Utilization category
Direct opening action Short-circuit protective device Fuse 6 A gG
250 V AC
i
10 A AC; 2,5 A DC
the
240 V AC; 250 V DC
e
AC-15, Ue/Ie 240 V / 3 A; DC-13, Ue/Ie 250 V / 0,27 A
p
acc. to IEC/EN 60947-5-1, Annex K
Protection class II, totally insulated
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2017-02-23 and will not be removed in case of changes.
Page 1 of 2
6088171054 / 2084-17
Mechanical data
Enclosure Thermoplastic, glass fibre reinforced (UL 94-V0) Cover Thermoplastic, glass fibre reinforced (UL 94-V0) Actuator Lever with roller (thermoplastic) Ambient air temperature -30 °C ... +80 °C Contact type 1 NC, 1NO (Zb) Mechanical life 3 x 10 Switching frequency ≤ 100 / min. Assembly 2 x M4 or 2 x M5 fixed position for safety applications Connection 4 screw connections (M3,5)
Conductor cross-sections
Cable entrance 1 x M16 x 1,5 Weight ≈ 0,05 kg Installation position operator definable Protection type IP65 acc. to EN 60529; DIN VDE 0470 T1
Actuation
The actuating device is preferably started from 1 sides. By loosening the 4 screws the actuation assembly can be rotated in 90 degree increments such that 4 actuation directions are possible. The actuation assembly is to be again fastened to the housing using the 4 screws.
6
operating cycles
Solid: 0,5 ... 1,5 mm² or Litz wire with ferrules: 0,5 ... 1,5 mm²
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1 VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EU Conformity
acc. to directive 2014/35/EU
Approvals
CSAUS, A300, Q300 (same polarity)
C
UL CCC
Notes
The degree of protection (IP code) specified applies solely to a property closed cover and the use of an equivalent cable gland with adequate cable.
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2017-02-23 and will not be removed in case of changes.
Page 2 of 2