Technical Data
Metal bodied limit switch
Series ENM2
Description ENM2-SU1 FF Article number 6087390032
Operating symbol
Operating diagram
Tolerance:
Operating Point ± 3,5 °;
On Off
Operating torque ± 10 %
Electrical Data
Rated insulation voltage U
Conv. thermal current I
Rated operational voltage U
Utilization category AC-15, U
400 V AC
i
10 A
the
240 V
e
e/Ie
Short-circuit protective device Fuse 2 A gG
Protection class
I
240 V / 3 A
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2017-01-19 and will not be removed in case of changes.
Page 1 of 2
6087390032 / 2022-17
Technical Data
Mechanical data
Enclosure Die-cast aluminium
Cover Sheet aluminium
Actuator Wobble stick with plastic slide
Ambient air temperature -30 °C ... +80 °C
Contact type 1 N.C., 1 N.O. (Zb)
Mechanical life 10 x 10
Switching frequency ≤ 100 / min.
Assembly 4 x M5
Connection 4 screw connections (M3,5)
Conductor cross-sections
Cable entrance 1 x M20 x 1,5
Weight ≈ 0,2 kg
Installation position operator definable
Protection type IP65 acc. to EN 60529
Actuation
The actuator can be approached from all directions with exception of the axial direction.
6
operating cycles
Solid: 0,5 ... 1,5 mm²
Litz wire with ferrules: 0,5 ... 1,5 mm²
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EU Conformity
acc. to directive 2014/35/EU
Approvals
CSAUS A300 (same polarity)
C
CCC
Notes
The degree of protection specified (IP code) applies only to a properly closed cover and the use of an equivalent cable gland
with adequate cable.
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2017-01-19 and will not be removed in case of changes.
Page 2 of 2
6087390032 / 2022-17