Technical Data
Plastic bodied limit switch
Series I88
Description I88-UV1Z HW 180GR RO13 Article number 6086321140
Operating symbol
Operating diagram
15-16
23-24
6
0mm
2
3
4,5
5mm
Tolerance:
Operating point ± 0,25 mm;
On Off
Operating force ± 10 %
Fixed positioning for
safety applications
Mounting screw
according to DIN 912 M5
Electrical Data
Rated insulation voltage U
Conv. thermal current I
Rated operational voltage U
Utilization category AC-15, U
Direct opening action
250 V AC
i
10 A
the
240 V
e
240 V / 3 A
p
acc. to IEC/EN 60947-5-1, annex K
e/Ie
Short-circuit protective device Fuse 10 A gG
Protection class II, totally insulated
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2015-07-29 and will not be removed in case of changes.
Page 1 of 2
6086321140 / 2405-14
Technical Data
Mechanical data
Enclosure Thermoplastic, glass fibre reinforced (UL 94-V0)
Cover Thermoplastic, glass fibre reinforced (UL 94-V0)
Actuator Lever (st) with roller (thermoplastic)
Ambient air temperature -30 °C ... +80 °C
Contact type 1 N.C., 1 N.O. (Zb)
Mechanical life 10 x 10
Switching frequency ≤ 100 / min.
Assembly 2 x M4
Connection 4 screw connections (M3,5)
Conductor cross-sections
Cable entrance 1 x M20 x 1,5
Weight ≈ 0,08 kg
Installation position operator definable
Protection type IP65 acc. to IEC/EN 60529
ID for safety engineering
B10d 20 x 106 switching cycles
6
operating cycles
Solid: 0,5 ... 1,5 mm² or
Litz wire with ferrules: 0,5 ... 1,5 mm²
Actuation
The actuating device is preferably started from 2 sides.
By loosening the 4 screws the actuation assembly can be rotated in 90 degree increments such that 8 actuation
directions are possible. The actuation assembly is to be again fastened to the housing using the 4 screws.
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
DIN EN ISO 13849-1
EU Conformity
acc. to directive 2006/95/EC
Approvals
CSAUS A300 (same polarity)
C
Notes
The degree of protection (IP code) specified applies solely to a property closed cover and the use of an equivalent cable gland
with adequate cable.
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2015-07-29 and will not be removed in case of changes.
Page 2 of 2
6086321140 / 2405-14