Bernstein 608.6167.102 Technical Data

Technical Data
Plastic bodied limit switch
Description I88-SU1Z RIWK 90GR Article number 6086167102
Operating symbol
Operating diagram
Tolerance: Operating Point ± 0,25 mm;
On Off
Electrical Data
Rated insulation voltage U Conv. thermal current I Rated operational voltage U Utilization category AC-15, U Direct opening action Short-circuit protective device Fuse 2 A gG Protection class II, totally insulated
Operating force ± 10%
i
the
e
p
250 V AC 10 A 240 V
240 V / 3 A
acc. to IEC/EN 60947-5-1, annex K
e/Ie
Fixed positioning for
safety applications
Mounting screw
according to DIN 912 M5
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2015-07-29 and will not be removed in case of changes.
Page 1 of 2
6086167102 / 2347-14
Technical Data
Mechanical data
Enclosure Thermoplastic, glass fibre reinforced (UL 94-V0) Cover Thermoplastic, glass fibre reinforced (UL 94-V0) Actuator Plunger (thermoplastic) Ambient air temperature -30° C ... +80° C Contact type 1 NC, 1 NO (Zb) Mechanical life 10 x 10 Switching frequency ≤ 100 / min. Assembly 2x M4 Connection 4 screw connections (M3,5) Conductor cross-sections Solid: 0,5 ... 1,5 mm² or
Cable entrance 1 x M20 x 1,5 Weight ≈ 0,07 kg Installation position operator definable Protection type IP65 acc. to EN 60529
ID for safety engineering
B10d 20 x 106 switching cycles
6
operating cycles
Litz wire with ferrules: 0,5 ... 1,5 mm²
Actuation
The actuating device is preferably started from 2 sides. By loosening the 4 screws the actuation assembly can be rotated in 90 degree increments such that 4 actuation directions are possible. The actuation assembly is to be again fastened to the housing using the 4 screws.
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1 VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1 DIN EN ISO 13849-1
EU Conformity
acc. to directive 2006/95/EC
Approvals
CSAUS A300 (same polarity)
C
Notes
The degree of protection (IP code) specified applies solely to a property closed cover and the use of an equivalent cable gland with adequate cable.
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2015-07-29 and will not be removed in case of changes.
Page 2 of 2
6086167102 / 2347-14
Loading...