Bernstein 608.6117.126 Technical Data

Technical Data
Plastic bodied limit switch
Series I88
Description
I88-U1Z RIWK 90GR
Article number
Operating symbol
Fixed positioning for
safety applications
Mounting screw
according to DIN 912 M5
Operating diagram
On Off
Tolerance: Operating point ± 0,25mm; Actuating force ± 10%
Electrical data
Rated insulation voltage U Conv. thermal current I Rated operational voltage U
250V AC
i
10A
the
240V
e
Utilization category AC-15, Ue /Ie 240V/3A Direct opening action acc. to IEC/EN 60947-5-1, Annex K Short-circuit protective device Fuse 10A gL/gG Protection class
II, totally insulated
6086117126
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice!
Document : 6086117126_en / Last update : 1 / 2324-06
Date of issue: 11.04.2006 / Page 1 of 2
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein-ag.de
Technical Data
Plastic bodied limit switch
Mechanical data
Enclosure Thermoplastic, glass fibre reinforced (UL 94-V0) Cover Thermoplastic, glass fibre reinforced (UL 94-V0) Actuator Roller (thermoplastic) Ambient air temperature -30°C … +80°C Contact type 1 NC, 1 NO (Zb) Mechanical life 10 x 106 switching cycles Switching frequency 100/min Assembly 2 x M4 Connection 4 screw connections (M3,5) Conductor cross-sections Solid: 0.5 ... 1.5mm² Litz wire with ferrules: 0.5 ... 1.5mm² Cable entrance 1 x M20x1,5 Weight 0,066kg Installation position Operator definable Protection type IP65 acc. to EN 60529; DIN VDE 0470 T1
Actuation
The actuating device is preferably started from 2 sides. By loosening the 4 screws the actuation assembly can be rotated in 90 degree increments such that 4 actuation directions are possible. The actuation assembly is to be again fastened to the housing using the 4 screws.
Standards
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EU Conformity
Approvals
Notes
The degree of protection (IP code) specified applies solely to a property closed cover and the use of an equivalent cable gland with adequate cable.
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
CCSAUS A300 (same polarity)
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice!
Document : 6086117126_en / Last update : 1 / 2324-06
Date of issue: 11.04.2006 / Page 2 of 2
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein-ag.de
Loading...