Bernstein 608.5121.103 Technical Data

Technical Data
Series BI2
Description BI2-U1Z HW 90GR RO11 Article number 6085121103
Operating symbol
Operating diagram
Tolerance: Operating Point ± 0,25 mm;
On Off
Operating force ± 10 %
Electrical Data
Rated insulation voltage U Conv. thermal current I Rated operational voltage U Utilization category AC15 U Direct opening action
400 V AC
i
10 A
the
240 V AC
e
p
acc. to IEC/EN 60947-5-1, annex K
/ I
240 V / 3 A
e
e
Short-circuit protective device Fuse 10 A gG Protection class II (totally insulated)
Fixed positioning for
safety applications
Mounting screw M5
according to DIN 912 or
DIN EN ISO 4762
BERNSTEIN AG . Hans-Bernstein-Straße 1 . 32457 Porta Westfalica . www.bernstein.eu
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2017-02-01 and will not be removed in case of changes.
Page 1 of 2
6085121103 / 2080-17
Technical Data
Mechanical data
Enclosure Thermoplastic, glass fibre reinforced Cover Thermoplastic, glass fibre reinforced Actuator Lever with roller (thermoplastic) Ambient air temperature -30 °C ... +80 °C Contact type 1 NC, 1 NO (Zb) Mechanical life 10 x 106 operating cycles Switching frequency ≤ 100 / min. Assembly 2 x M4 / 2 x M5 / 2 x M3 front mounting Connection 4 screw connections (M3,5)
Conductor cross-sections
Cable entrance 2 x M16 x 1,5 Weight ≈ 0,09 kg Installation position operator definable Protection type IP65 acc. to IEC/EN 60529; DIN VDE 0470 T1
ID for safety engineering
B10d 20 x 106 cycles
Solid: 0,5 ... 1,5 mm² Litz wire with ferrules: 0,5 ... 1,5 mm²
Actuation
The actuating device is preferably started from 1 side. By loosening the 4 screws the actuation assembly can be rotated in 90 degree increments such that 4 actuation directions are possible. The actuation assembly is to be again fastened to the housing using the 4 screws. Standards VDE 0660 T100, DIN EN 60947
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1 VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1 DIN EN ISO 13849-1
EU Conformity
acc. to directive 2014/35/EU
Approvals
CSAUS A300, Q300
C
CCC
Notes
The degree of protection specified (IP code) applies only to a properly closed protective guard and the use of an equivalent cable gland with adequate cable.