Technical Data
Plastic bodied limit switch
Series IN62
Description IN62-A2Z SK Article number 6083000203
Operating symbol
Fixed positioning with
e.g. fixing screw M5
according to the standard
Operating diagram
DINENISO4762.
[mm]
0
21-22
11-12
[N]
1,5
1,0
1,8 p
5,9
ON OFF
Electrical Data
Rated insulation voltage U
Rated impulse withstand voltage U
Rated operational voltage U
Rated supply frequency AC 50 / 60 Hz
Overvoltage category II acc. EN 60947-1 annex H table H1
Conv. thermal current I
Minimum current 1 mA
Reliability acc. EN 60947-5-4 @ 24 V DC, 10 mA, 1 mA, U
Utilization category
Direct opening action
Short-circuit protective device Fuse 4 A gG
Rated conditional short-circuit current 400 A
Max. contact resistance 25 mOhm (unused)
Electrical life on request
10,5
Tolerance:
Operating point ± 0,25 mm;
Direct opening action + 0,25 mm
Operating force ± 10 %
400 V
i
4 kV
imp
240 V AC / 24 V DC
e
5 A
the
AC 15, U
DC 13, Ue/Ie 24 V / 1,5 A
(B300 table A.1)
p
acc. IEC/EN 60947-5-1, annex K; direct opening force: 25 N
240 V / 1,5 A
e/Ie
2,4 V DC
kd
±5°
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2017-05-23 and will not be removed in case of changes.
Page 1 of 3
6083000203 / 2261-17
Technical Data
Mechanical data
Enclosure Thermoplastic, glass fibre reinforced (UL 94-V0)
Cover Thermoplastic, glass fibre reinforced (UL 94-V0)
Actuator Plunger (Thermoplastic (UL 94-HB))
Actuating force F
Operating temperature -30 °C ... +75 °C
Storage temperature -40 °C ... +80 °C
Protection type IP67 acc. EN 60529
Pollution degree (built-in switch) 3
Contact material silver
Device Class (built-in switch) Category E (MC3+CC2+SC1) acc. EN 60947-1 annex Q
Contact type 2 N.C. (Form Zb)
Isolating distance 4 mm (2x2 mm)
Operating rate V 0,06 m/min ≤ V ≤ 30 m/min
Bounce duration ms The value depends on the operating rate.
Switchover time ms The value depends on the operating rate.
Switching frequency ≤ 60 / min.
Mechanical life 10 x 10
Mission time ≤20 years
Connection 4 screw connections (M3)
Conductor cross-sections Solid or Litz wire with ferrules 0,34 mm² - 1,5 mm²; AWG 22-16
Cable entrance 1 x M20 x1,5
Weight ≈ 0,06 kg
Installation position operator definable
10 N ≤ FB ≤ 30 N
B
6
operating cycles
Actuation
The push bolt actuator is mainly intended to be actuated along its axis.
ID for safety engineering
B10d N.C. 20 x 10
B10d N.O.
6
cycles Tbd (check acc. to DIN EN 60947-5-1)
6
cycles (Tbd contact with reduced power for consumers
1 x 10
with resistive load)
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
VDE 0660 T211, DIN EN 60947-5-4, IEC 60947-5-4
UL 60947-1, CAN/CSA-22.2 No. 60947-1-13
UL 60947-5-1, CAN/CSA-C22.2 No. 60947-5-1-14
DIN EN ISO 13849-1
DIN EN ISO 13849-2
UL 508
EU Conformity
acc. to directive 2006/42/EC (Safety-of-Machinery-Directive)
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2017-05-23 and will not be removed in case of changes.
Page 2 of 3
6083000203 / 2261-17