Technical Data
Foot-switch
Series F1
Description F1-ZSD Article number 6061500559
Switching symbol
(Three-Step-Safety Switch)
1. position
Off-position
2. position
On-position
Operating diagramme
Backstroke pestleStroke pestle
1. Position
2. Position
Pressure
point
ON OFF
3. position
Off-position
with positive opening
To reach the 3rd position,
the tactile touch has to be
surmounted.
3. Position
BERNSTEIN AG . Hans-Bernstein-Straße 1 .
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2015-10-30 and will not be removed in case of changes.
Page 1 of 3
6061500559 / 2784-15

Technical Data
Electrical Data
Rated insulation voltage U
Conv. thermal current I
Rated impulse withstand voltage U
Rated operational voltage U
Utilization category
Direct opening action
Short-circuit protective device D-Fuse 4 A gG
Protection class I
Mechanical data
Enclosure AL, die-cast
Protective guard (Accident protection cover UN) AL, die-cast
Actuator Foot lever (PA)
Ambient air temperature
Contact type (each pedal) 1 NC, 2 NO. (Zb)
Operating force (pedal centre) 1. position
2. position
Pressure point (each pedal) ≈ 200 N
Mechanical life (each pedal)
Sequence of the switching position: 1 – 2 – 1
or: 1– 2 – 3 – 1
Switching frequency max. 30/min
Assembly 2 x M8
Connection screw connections (M3,5)
Protection ground 2 x M4
Conductor cross-sections
Cable entrance 1 x M20 x 1,5
Weight ≈ 1,6 kg
Protection type IP67 in accordance with IEC/EN 60529
250 V
i
5 A
the
2,5 KV
imp
240 V AC and 24 V DC
e
AC-15, Ue /Ie 240 V AC / 1,5 A 50-60 Hz
DC-13, Ue /Ie 24 V DC/ 1,0 A
p
acc. to IEC/EN 60947-5-1, annex K (pedal stop)
Operating temperature range: -10 °C to +50 °C
Storage temperature range: -25 °C to +70 °C
10 N
25 N
6
10 x 10
operating cycles
1 x 106 operating cycles
Solid: 0,5 ... 1,5 mm²
Litz wire with ferrules: 0,5 ... 1,5 mm²
ID for safety engineering
B10d
Sequence of the switching position: 1 – 2 – 1
or: 1– 2 – 3 – 1
BERNSTEIN AG . Hans-Bernstein-Straße 1 .
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2015-10-30 and will not be removed in case of changes.
6
10 x 10
cycles
1 x 106 cycles
Page 2 of 3
6061500559 / 2784-15

Technical Data
Regulations
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
DIN EN 61326-3-1
DIN EN ISO 13849-1
EU Conformity
acc. to directive 2006/95/EG
Approvals
DGUV
CULUS
Function
Normally open contacts: 23 – 24, 33 – 44; Signalling contact: 11 – 12
• Position 1: OFF position of the operating contacts (the pedal is not actuated)
• Position 2: ON position of the operating contacts (the pedal is actuated to as far as the pressure point)
• Position 3: OFF position of the operating contacts (the pedal is fully actuated)
If the three-stage enable switch is actuated in position 2, it returns to position 1 when it is released. The threestage
enable switch changes from position 2 to position 3, if it gets further pressed unter after the resistance of
the pressure point.
The actuation of the operating contacts is made by a positive opening.
Once the pedal is not pressed, the three-stage enable switch returns to position 1.
The operating contacts are opened in the return stroke.
Notes
The specified protection classification (IP code) applies only when the cover is closed and the appropriate cable is used, in
accordance with the clamping range of the above mentioned cable gland.
BERNSTEIN AG . Hans-Bernstein-Straße 1 .
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2015-10-30 and will not be removed in case of changes.
Page 3 of 3
6061500559 / 2784-15