Bernstein 604.1718.707 Technical Data

Technical Data
Metal Switches
Series D
Description
D-A1Z RW
Article number
Operating symbol
Operating diagram
ON OFF
Tolerances Operating point: ± 0,25mm; Actuating force: ± 10%
Electrical data
Rated insulation voltage U Conv. thermal current I Rated operational voltage U
400 VAC
i
10A
the
240V
e
Utilization category AC-15, Ue /Ie 240V/3A Positive opening NC contact IEC/EN 60947-5-1, Annex K Short-circuit protective device Fuse 10A gL/gG Protection class
I
6041718707
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice!
Date of issue: 16.01.2006 / Page 1 of 2
Document: 6041718707_en / Last update: 2 / 2031-06
Vorlage : 0850174282 Orig. 1
Technical Data
Metal Switches
Mechanical data
Enclosure Die-cast aluminium Cover Sheet aluminium Actuator Push bolt with roller (st) Ambient air temperature -30°C ... +80°C Contact type 3 NC (Zb) Mechanical life 10 x 106 operating cycles
Switching frequency Assembly 4 x M5 Connection 2 screw terminals (M4) Conductor cross-sections Solid: 0.5 ... 1.5mm² Litz wire with ferrules: 0.5 ... 1.5mm² Cable entrance 2 x M20x1.5 Weight Installation position Operator definable Protection type IP65 acc. to IEC/EN 60529
Actuation
By loosening the 4 screws the actuation assembly can be rotated in 90 degree increments such that 4 actuation directions are possible. The actuation assembly is to be again fastened to the housing using the 4 screws.
Standards
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EU Conformity
Approvals
Notes
The degree of protection specified (IP code) applies only to a properly closed cover and the use of an equivalent cable gland with adequate cable.
100 / min.
0,28 kg
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
CSAUS A300 (same polarity)
C
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice!
Date of issue: 16.01.2006 / Page 2 of 2
Document: 6041718707_en / Last update: 2 / 2031-06
Vorlage : 0850174282 Orig. 1