Technical Data
Metal Switches
Series SN2
Description
SN2-SU1Z AHS-V
Article number
Operating symbol
Operating diagram
ON OFF
Tolerance:
Operating point ± 3,5°;
Operating torque ± 10%
Electrical data
Rated insulation voltage U
Conv. thermal current I
Rated operational voltage U
i
the
e
400 VAC
10A
240V
Utilization category AC-15, Ue /Ie 240V/3A
Direct opening action acc. to IEC/EN 60947-5-1, Annex K
Short-circuit protective device Fuse 2A gL/gG
Protection class
I
6033385003
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Document: 6033385003_en / Last update: 1 / 2155-07
Date of issue: 02.03.2007 / Page 1 of 2
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany /
Vorlage : 0850174282 Orig. 1
Technical Data
Metal Switches
Mechanical data
Enclosure Die-cast aluminium
Cover Sheet aluminium
Actuator Turret head (Zn-die cast), lever (st),
roller (thermoplastic)
Ambient air temperature -30°C ... +80°C
Contact type 1 NC, 1 NO (Zb)
Mechanical life 10 x 106 operating cycles
Switching frequency ≤ 100 / min.
Assembly 4 x M5
Connection 4 screw terminals (M3.5)
Conductor cross-sections Solid: 0.5 ... 1.5mm²
Litz wire with ferrules: 0.5 ... 1.5mm²
Cable entrance 3 x M20x1.5
Weight ≈ 0,28 kg
Installation position Operator definable
Protection type IP65 acc. to IEC/EN 60529
Actuation
The actuating device is preferably started from 2 sides.
By loosening the 4 screws the actuation assembly can be rotated in 90 degree increments such that 8 actuation
directions are possible.
The actuation assembly is to be again fastened to the housing using the 4 screws.
Standards
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EU Conformity
Approvals
Notes
The degree of protection (IP code) specified applies solely to a property closed cover and the use of an
equivalent cable gland with adequate cable.
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
CCSAUS A300 (same polarity)
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Document: 6033385003_en / Last update: 1 / 2155-07
Date of issue: 02.03.2007 / Page 2 of 2
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany /
Vorlage : 0850174282 Orig. 1