Bernstein 603.3367.045 Technical Data

Technical Data
Metal Switches
Series SN2
SN2-SU1Z RIW 90GR
Article number
Operating symbol
Operating diagram
ON OFF
Tolerances Operating point: ± 0,25 mm; Actuating force: ± 10 %
Electrical data
Rated insulation voltage U Conv. thermal current I Rated operational voltage U
i
the
e
400 V AC 10 A
240 V Utilization category AC-15, Ue /Ie 240 V /3 A Direct opening action acc. to IEC/EN 60947-5-1, Annex K Short-circuit protective device Fuse 2 A gL/gG Protection class
I
6033367045
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice!
Document: 6033367045_en / Last update: 1 / 2811-10
Date of issue: 16.02.2011 / Page 1 of 2
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany / www.bernstein.eu
Vorlage : 0850174282 Orig. 1
Technical Data
Metal Switches
Mechanical data
Enclosure Die-cast aluminium Cover Sheet aluminium Actuator Roller, St Ambient air temperature -30° C ... +80° C Contact type 1 NC, 1 NO (Zb) Mechanical life 10 x 106 operating cycles Switching frequency 100 / min. Assembly 4 x M5 Connection 4 screw terminals (M3,5) Conductor cross-sections Solid: 0,5 ... 1,5 mm² Litz wire with ferrules: 0,5 ... 1,5 mm² Cable entrance 3 x M20x1,5 Weight 0,2 kg Installation position operator definable Protection type IP65 acc. to IEC/EN 60529
Actuation
By loosening the 4 screws the actuation assembly can be rotated in 90 degree increments such that 2 actuation directions are possible. The actuation assembly is to be again fastened to the housing using the 4 screws.
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1 VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EU Conformity
Approvals
CSA
C
US
Notes
1)
The degree of protection specified (IP65) applies only to a properly closed cover and the use of an equivalent
cable gland with adequate cable and fitted inserts.
1)
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice!
Document: 6033367045_en / Last update: 1 / 2811-10
Date of issue: 16.02.2011 / Page 2 of 2
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany / www.bernstein.eu