Bernstein 602.1177.080 Technical Data

Technical Data
Metal bodied limit switch
Series GC
Description GC-SU1Z KNW Article number 6021177080
Operating diagram
Blind hole for fitting pin Ø4; 5.5 deep
Tolerance: Operating point ±0,25 mm;
On Off
Actuating force ±10 %
Electrical Data
Rated insulation voltage U Conv. thermal current I Rated operational voltage U
400 V AC
i
10 A
the
240 V
e
Utilization category AC-15, Ue/Ie 240 V / 3 A Positive opening NC contact
p
acc. to IEC/EN 60947-5-1, Annex K Short-circuit protective device Fuse 2 A gG Protection class
BERNSTEIN AG . Hans-Bernstein-Straße 1 .
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2018-01-11 and will not be removed in case of changes.
I
Page 1 of 2
6021177080 / 2093-17
Technical Data
Mechanical data
Enclosure Die-cast aluminium Cover Sheet aluminium Actuator Lever (st-plate), roller (thermoplastic) Ambient air temperature -30 °C ... +80 °C Contact type 1 NC, 1 NO (Zb) Mechanical life 10 x 10 Switching frequency ≤ 100 / min. Assembly 2 x M4 Connection 4 screw connections (M3,5)
Conductor cross-sections
Cable entrance 1 x M20 x 1,5 (clamping range 5,5 - 6,1 mm) Weight ≈ 0,16 kg Installation position operator definable Protection type IP65 acc. to IEC/EN 60529
ID for safety engineering
B10d 20 x 10
6
operating cycles
Solid: 0,5 ... 1,5 mm² or Litz wire with ferrules: 0,5 ... 1,5 mm²
6
cycles
Actuation
By loosening the 4 screws the actuation assembly can be rotated in 90 degree increments such that 4 actuation directions are possible. The actuation assembly is to be again fastened to the housing using the 4 screws.
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1 VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1 DIN EN ISO 13849-1
EU Conformity
acc. to directive 2014/35/EU (Low-Voltage-Directive)
Approvals
CSAUS A300 (same polarity)
C
CCC
Notes
The switch must not be used as a stop. The specified protection classification (IP code) applies only when the cover is closed and the appropriate cable is used, in accordance with the clamping range of the above mentioned cable gland.
BERNSTEIN AG . Hans-Bernstein-Straße 1 .
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2018-01-11 and will not be removed in case of changes.
Page 2 of 2
6021177080 / 2093-17
Loading...