Technical Data
Metal bodied limit switch
Series GC
Description GC-U1 LIW Article number 6021144293
Operating symbol
Operating diagram
0 mm
1
1,5
9 mm
Tolerance:
Operating point ± 0,25 mm;
On Off
Electrical Data
Rated insulation voltage U
Conv. thermal current I
Rated operational voltage U
Utilization category AC-15, U
Short-circuit protective device Fuse 10 A gG
Protection class
Actuating force ± 10 %
i
the
e
400 V AC
10 A
240 V
e/Ie
I
Blind hole for fitting pin
Ø4; 5.5 deep
240 V / 3 A
BERNSTEIN AG . Hans-Bernstein-Straße 1 .
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2017-03-14 and will not be removed in case of changes.
Page 1 of 2
6021144293 / 2093-17
Technical Data
Mechanical data
Enclosure Die-cast aluminium
Cover Sheet aluminium
Actuator Telescopic plunger (st)
Ambient air temperature -30 °C ... +80 °C
Contact type 1 NC, 1 NO (Zb)
Mechanical life 10 x 10
Switching frequency ≤ 100 / min.
Assembly 2 x M4
Connection 4 screw connections (M3,5)
Conductor cross-sections
Cable entrance 1 x M20 x 1,5
Weight ≈ 0,16 kg
Installation position operator definable
Protection type IP65 acc. to IEC/EN 60529
Actuation
The push bolt actuator is mainly intended to be actuated along its axis.
Side actuation will considerably reduce switch life.
6
operating cycles
Solid: 0,5 ... 1,5 mm² or
Litz wire with ferrules: 0,5 ... 1,5 mm²
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EU Conformity
acc. to directive 2014/35/EU
Approvals
CSAUS A300 (same polarity)
C
CCC
Notes
The switch must not be used as a stop.
The degree of protection specified (IP code) applies only to a properly closed cover and the use of an equivalent cable gland
with adequate cable.
BERNSTEIN AG . Hans-Bernstein-Straße 1 .
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2017-03-14 and will not be removed in case of changes.
Page 2 of 2