Technical Data
Safety switch
Series SLK – with separate actuator
Description SLK-M-UC-81-R0-A0-L0-0 Article number 6018169062
Position monitoring
of guard locking
(not wired)
Termination electromagnet
with contact position
E1, E2 without current
The actuator is not
included in the scope of
delivery. It can only be purchased in
conjunction with the safety switch.
E1, E2 with current
Operating diagram
Actuator
withdraw
Actuator
inserted
On Off
Tolerances:
Actuating force: ± 15 %
BERNSTEIN AG . Hans-Bernstein-Straße 1 .
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2018-02-19 and will not be removed in case of changes.
Page 1 of 3
6018169062 / 2112-18

Technical Data
Electrical data
Protection class II, totally insulated
Contact elements
Rated insulation voltage U
Rated impulse withstand voltage U
Conv. thermal current I
Utilization category AC-15, U
Direct opening action
Short-circuit protective device 4 A gG
Electro magnets
Duty cycle 100 % ED (at E1; E2)
Temperature class F (155 °C)
Inrush power consumption 12 VA (0,2 s)
Permanent power consumption 4,4 VA
Switch operations permanent 600 / h
Operating voltage 24 V AC / DC
Mechanical data
Enclosure Thermoplastic, glass fibre reinforced (UL 94-V0)
Cover Thermoplastic, glass fibre reinforced (UL 94-V0)
Actuating head Thermoplastic, glass fibre reinforced / Zn-GD
Actuator Separate actuator (Steel / PA)
Minimum actuating radius R
Velocity for actuating V
Extraction force ≥ 27 N
Interlocking principle Magnetic force
Unlocking Spring force
Hold on force F
Ambient air temperature -25 ° C ... +70 ° C
Contact type 4 NC
Switching principle 4 slow make and break contact elements
Mechanical life 1 x 10
Assembly 4 x M5
Connection Spring-clamp connection
Conductor cross-sections 0,5 ... 1,5 mm² flexible
Cable entrance 3 x M20 x 1,5
Weight ≈ 0,34 kg
Installation position operator definable
Protection type IP67 acc. to IEC/EN 60529
250 V
i
2,5 kV
imp
5 A
the
p
according to IEC/EN 60947-5-1, Annex K
see separate actuators data sheet
min
0,5 m/
max
≤ 1500 N acc. to GS-ET-19
Zh
/ I
230 V / 2,5 A
e
e
s
6
switching cycles (at max. 600 switch operations / h)
ID for safety engineering
B10d 2 x 10 6 cycles
Actuation
4 different actuating directions achievable by rotating the actuating head.
Changing between horizontal and vertical actuating direction by setting the actuating head in the requested direction.
BERNSTEIN AG . Hans-Bernstein-Straße 1 .
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2018-02-19 and will not be removed in case of changes.
Page 2 of 3
6018169062 / 2112-18

Technical Data
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
GS-ET-19
DIN EN ISO 13849-1
EU Conformity
acc. to directive 2006/42/EC (Safety-of-Machinery-Directive)
Approvals
DGUV
CSAUS B300 (same polarity)
C
CCC
Notes
The degree of protection (IP code) specified applies solely to a property closed cover and the use of an equivalent cable gland
with adequate cable.
The switch may not be used as a mechanical stop.
In case that power is removed from the solenoid the safety switch will be no longer in a locked position. Operator can open the
guard! Attention has to be given to the risks of the machine in this situation!
BERNSTEIN AG . Hans-Bernstein-Straße 1 .
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2018-02-19 and will not be removed in case of changes.
Page 3 of 3
6018169062 / 2112-18