Bernstein 601.6469.067 Technical Data

1
Safety switch
Series SKT- with separate actuat
Description SKT-SA2Z M3 Article number 6016469067
Operating symbol
Operating diagram
or
Tolerance: Operating Point ± 0,25 mm;
On Off
Radial actuation / dimensions
Operating force ± 10 %
Actuator withdrawn
Actuator M3Fixed positioning for
safety applications
Mounting screw
according to DIN 912 M5
inserted
To prevent manipulation of the actuator, The unclosed safety screw must be used (M4x8)
5mm ≤ A ≤ 8 mm, R ≥ 150 mm The min. radius refers to a pivot at the top of the cap (S
BERNSTEIN AG . Hans-Bernstein-Straße 1 .
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2016-06-29 and will not be removed in case of changes.
)
0
Page 1 of 3
6016469067 / 2208-16
Electrical Data
Rated insulation voltage U Conv. thermal current I Rated operational voltage U Utilization category AC-15, U Direct opening action Short-circuit protective device Fuse 6 A gG Protection class II, totally insulated
Mechanical data
Enclosure PBT Cover PA 6.6 Actuator Separate actuator (St-stainless steel) Extraction force 12 N Ambient air temperature -30 °C … +80 °C Contact type 2 NC (Zb) Mechanical life 1 x 10 Switching frequency ≤ 30 / min. Assembly Safety switch 2 x M4 or M5 Actuator 2 x M4 (supplied) Connection screw connections (M3,5) Conductor cross-sections Solid: 0,5 ... 1,5 mm²
Cable entrance 1 x M16 x 1,5 Weight ≈ 0,09 kg Protection type IP65 acc. to IEC/EN 60529
250 V
i
10 A
the
240 V AC; 250 V DC
e
p
according to IEC/EN 60947-5-1, Annex K
6
switch operations
/Ie 240 V / 3 A; DC-13, Ue /Ie 250 V / 0,27 A
e
Litz wire with ferrules: 0,5 ... 1,5 mm²
ID for safety engineering
B10d 2 x 10
Actuation
1.draw clasp out
2.turn actuator head (4 x 90° rotation)
3.press-on clasp
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1 VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1 DIN EN ISO 13849-1
EU Conformity
acc. to directive 2006/42/EC
6
switching cycles
BERNSTEIN AG . Hans-Bernstein-Straße 1 .
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2016-06-29 and will not be removed in case of changes.
Page 2 of 3
6016469067 / 2208-16
Loading...
+ 1 hidden pages