Bernstein 601.6409.150 Technical Data

1
Safety switch
Series SKT- with separate actuat
Description SKT-SU1Z FI50 M3 Article number 6016409150
Operating symbol
Operating diagram
or
Tolerance: Operating Point ± 0,25 mm;
On Off
Radial actuation / dimensions
Operating force ± 10 %
Actuator withdrawn
Actuator M3Fixed positioning for
safety applications
Mounting screw
according to DIN 912 M5
inserted
To prevent manipulation of the actuator, The unclosed safety screw must be used (M4x8)
A = 5mm, R ≥ 150mm The min. radius refers to a pivot at the top of the cap (S
BERNSTEIN AG . Hans-Bernstein-Straße 1 .
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2016-06-29 and will not be removed in case of changes.
)
0
Page 1 of 3
6016409150 / 2208-16
Electrical Data
Rated insulation voltage U Conv. thermal current I Rated operational voltage U Utilization category AC-15, U Direct opening action Short-circuit protective device Fuse 6 A gG Protection class II, totally insulated
Mechanical data
Enclosure PBT Cover PA 6.6 Actuator Separate actuator (St-stainless steel) Extraction force 50 N Ambient air temperature -30 °C … +80 °C Contact type 1 NC, 1 NO (Zb) Mechanical life 1 x 10 Switching frequency ≤ 30 / min. Assembly Safety switch 2 x M4 or M5 Actuator 2 x M4 (supplied) Connection screw connections (M3,5) Conductor cross-sections Solid: 0,5 ... 1,5 mm²
Cable entrance 1 x M16 x 1,5 Weight ≈ 0,09 kg Protection type IP65 acc. to IEC/EN 60529
250 V
i
10 A
the
240 V AC; 250 V DC
e
p
according to IEC/EN 60947-5-1, Annex K
5
switch operations
/Ie 240 V / 3 A; DC-13, Ue /Ie 250 V / 0,27 A
e
Litz wire with ferrules: 0,5 ... 1,5 mm²
ID for safety engineering
B10d 2 x 10
Actuation
1.draw clasp out
2.turn actuator head (4 x 90° rotation)
3.press-on clasp
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1 VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1 DIN EN ISO 13849-1
EU Conformity
acc. to directive 2006/42/EC
5
switching cycles
BERNSTEIN AG . Hans-Bernstein-Straße 1 .
Technical modifications and errors excepted.
The technical datasheet corresponds to the technical state as of 2016-06-29 and will not be removed in case of changes.
Page 2 of 3
6016409150 / 2208-16