Bernstein 601.6169.027 Technical Data

Technical Data
Safety switch
Series SK – with separate actuator
Operating symbol
Operating diagram
ON OFF
Tolerances Operating point: ± 0,25 mm; Actuating force: ± 10 %
SK-UV16Z M
Article number
6016169027
Electrical data
Rated insulation voltage U Conv. thermal current
i
I
the
400 V AC
5A Utilization category AC-15, Ue /Ie 240 V / 1,5 A Direct opening action according to IEC/EN 60947-5-1, Annex K Short-circuit protective device Fuse 6 A gL/gG Protection class
II, totally insulated
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of he actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice!
Document : 6016169027_en / Last update: 1 / 2782-10
Date of issue: 30.11.2010 / Page 1 of 2
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein.eu
Vorlage : 0850174285 Orig. 2
Technical Data
Safety switch
Mechanical data
Enclosure Thermoplastic, glass fibre reinforced (UL94-V0) Cover Thermoplastic, glass fibre reinforced (UL94-V0) Actuator Separate actuator (St-stainless steel) Extraction force 10 N Ambient air temperature -30 °C … +80 °C Contact type 1 NC-contact, 2 NO-contact (Zb) Mechanical life 1 x 106 switch operations Switching frequency 30 / min. Assembly Safety switch 2 x M5 Actuator 2 x M5 Connection 6 screw connections (M3) Conductor cross-sections Single core 0,5 - 1,5 mm² Litz wire with connwctor sleeve: 0,5 -1,5 mm² Cable entrance 2 x M20 x 1,5 Weight 0,15 kg Installation position operator definable Protection type IP65 acc. to IEC/EN 60529
Actuation
Turning the cap (pos A/B) allows 4 different directions of drive. Cover (1) has to be opened before turning the cap (2). Insert the screwdriver into the gap between housing and cap and turn until the cap snaps off. Remove the cap, turn it 180° (4), latch it into the housing and close the cover.
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1 VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EU Conformity
Approvals
TÜV Rheinland, Type Approved
CSAUS B300 (same polarity)
C
Notes
The degree of protection (IP code) specified applies solely to a property closed cover and the use of an equivalent cable gland with adequate cable. The switch may not be used as a mechanical stop. Radial actuation may reduce the mechanical life. The min. radius refers to a pivot at the top of the cap (S
).
0
Tapped holes not in use must be closed with blind plugs.
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for defects on account of possible variations of he actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to change without notice!
Document : 6016169027_en / Last update: 1 / 2782-10
Date of issue: 30.11.2010 / Page 2 of 2
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein.eu
Vorlage : 0850174285 Orig. 2