Berner MAX1030E User Manual

No.: DS-472
FDA
RECOMMENDED
Date: October, 2011
STANDARD FEATURES
7 1/2” high • 1/5 hp direct driven motor(s) • Factory installed “Intelliswitch” digital, programmable • controller - see features below Aluminum air directional vanes • Clear anodized aluminum exterior cabinet • Wall mounting plate and 1/4” threaded inserts for top • mounting Aluminum cross-flow blower wheels• Two year parts warranty• Crafted with Pride in the USA •
HEATER FEATURES
OPTIONAL FEATURES
MAXAIR
Electric
Data Sheet
Helical coil with point suspension of elements for • longer life Available single or three phase (not all models)• Easily replaceable heating elements• Galvanized steel frame• Thermal protection against overheating•
Stainless steel or custom color finish• Reduced kW available (consult factory)•
Lab Data
MODEL
Nozzle
Width (in)
Max FPM at Nozzle
Max CFM at Nozzle
CFM at
Nozzle
Avg.
Outlet
Vel.
(fpm)
Air
Volume
(scfm)
Power
Rating
(kW)
Outlet
Vel.
Unif. (%)
Motor(s)
@ hp
Electric
Capacity
(kW)
Temp
Rise
°F
Net
Wgt
(lbs)
MAX1030E 28.00 3100 914 731 1777 691 .18 89 1 @ 1/5 5.4 or 7.2 24 40.5
MAX1036E 35.25 3600 1465 1172 2118 1036 .32 92 1 @ 1/5 10 30 45.5
MAX1042E 41.25 3000 1370 1096 2115 1212 .32 93 1 @ 1/5 10 26 50
MAX1048E 47.25 2800 1805 1444 2104 1381 .32 94 1 @ 1/5 14.4 33 56
MAX1060E 59.00 3100 1950 1560 2052 1682 .32 95 1 @ 1/5 14.4 28 68.5
MAX1072E 72.50 3600 3026 2421 2118 2072 .32 95 1 @ 1/5 20 30 76.5
MAX2084E 84.25 3000 2740 2192 2115 2424 .64 93 2 @ 1/5 20 26 100
MAX2096E 96.25 2800 3610 2888 2104 2762 .64 94 2 @ 1/5 28.8 33 111.5
MAX2120E 119.75 3100 3901 3121 2046 3364 .64 95 2 @ 1/5 28.8 28 137
POWER SUPPLIES/MOTOR AMP DRAWS
Volts 120 208 240 110* 220*
Phase 1 1 1 1 1
Hertz 60 60 60 50 50
Amps per Motor 3.4 1.7 1.7 2.8 1.4
*Operation at 50 Hz will generate approximately a 17% reduction in performance.
Sound level measured 10’ (3m) from the unit in free field: 1 & 2 motor(s): 54 dBA, 57 dBA
HEATER kW 208/1/60 240/1/60 208/3/60 240/3/60 480/3/60**
5.4 26.0 22.5 - - -
7.2 34.6 30.0
10.0 48.1 41.7 27.8 24.1 12.0
14.4 69.2* 60.0* 40.0 34.6 17.3
20.0 - - 55.5* 48.1* 24.1
28.8 - - 79.9* 69.3* 34.6
*Two circuits required. ** A separate 120/208 or 240 power supply required for motors.
HEATER kW/AMP DRAWS
Intelliswitch Features:
u Time Delay u Low Voltage Control Circuit u 10 Speed Fan Slection u Time Clock u On/Off/Auto Operation u LED Display u Start/Stop Times u Lockable Display u Thermostat
Berner reserves the right to alter specifications without prior notice.
Berner International Corporation New Castle, PA 16101 / USA / Telephone (724) 658-3551 / FAX (724) 652-0682 / www.berner.com / airdoors@berner.com MADE IN U.S.A. ©Copyright, 2011 Berner International Corporation