No.: DS-337
Date: December, 2011
For Door Heights To 12’ (environmental separation)
KSA
Electric
Data Sheet
STANDARD FEATURES
½ hp single speed motor(s) •
Factory mounted control panel - 24 volt control•
High efficiency, low noise Pro-V Nozzle (patent pending)•
Galvanized steel blower wheels and housing •
HEATER FEATURES
Helical coil with point suspension of elements•
Available single or three phase•
Galvanized steel frame•
Thermally protected against overheating•
Airfoil aluminum air directional vanes
Powder coated finish with aluminum inlet screen•
16 gauge aluminized steel cabinet •
½” mounting holes (wall or top mounting)•
OPTIONAL FEATURES
Reduced kW available (see sheet KW-337)•
½ hp multi-speed motor(s) (consult factory)•
No field assembly required •
Two year parts warranty•
Crafted with Pride in the USA •
Lab Data
N o z z l e
Model
KSA1036E 36 5166 3933 2556 1728 1512 0.51 87 1 @ ½
KSA1042E 42 5550 5042 3278 1551 1583 0.52 89 1 @ ½
KSA1048E 48 5292 4816 3130 1366 1594 0.53 78 1 @ ½
KSA1060E 66 4800 5180 3367 1049 1530 0.53 74 1 @ ½
KSA2060E 66 5292 6560 4264 2010 2931 0.99 85 2 @ ½
KSA2072E 72 5166 7865 5112 1728 3024 1.02 87 2 @ ½
KSA2078E 78 5166 8521 5538 1633 3095 1.03 87 2 @ ½
KSA2084E 84 5550 10085 6555 1551 3166 1.04 89 2 @ ½
KSA2096E 99 5292 9631 6260 1366 3188 1.06 78 2 @ ½
KSA3096E 99 5292 10866 7063 1551 4332 1.53 88 3 @ ½
KSA2108E 108 4800 9324 6061 1366 3124 1.06 74 2 @ ½
KSA3108E 108 5166 11798 7669 1728 4536 1.53 87 3 @ ½
KSA2120E 117 4800 10360 6734 1049 3060 1.06 74 2 @ ½
KSA3120E 117 5166 13109 8521 1604 4678 1.55 87 3 @ ½
KSA3132E 132 5292 13243 8608 1484 4760 1.57 78 3 @ ½
KSA3144E 144 5292 14447 9391 1366 4782 1.59 78 3 @ ½
KSA4144E 144 5166 15730 10225 1728 6048 2.04 87 4 @ ½
Width
(in)
Max
FPM at
Nozzle
Max
CFM at
Nozzle
CFM at
Nozzle
A v g .
Out. Vel.
(fpm)
A i r
V o l u m e
(scfm)
P o w e r
R a t i n g
(kW)
O u t l e t
Vel. Unif.
(%)
Motor(s)
@ hp
E l e c t r i c
Capacity
(kW)
14 47,782
14 47,782
14 47,782
14 47,782
28 95,564
28 95,564
28 95,564
28 95,564
28 95,564
42 143,346
28 95,564
42 143,346
28 95,564
42 143,346
42 143,346
42 143,346
56 191,128
H e a t e r
C a p a c i t y
(BTU/hr)
T e m p .
Rise
(°F)
29 86
28 92
28 97
29 108
30 160
29 169
28 175
28 180
28 190
30 236
28 233
29 279
29 240
28 286
28 307
28 321
29 367
Net
W g t .
(lbs)
Lab tested and heater data based on AMCA licensed data from base (unheated) units
Note: Single phase units have a 14 kW max.
POWER SUPPLIES/MOTOR AMP DRAWS
VOLTS 208 240 208 240 480 600 220 380
Sound level measured 10’ (3m) from the unit in free field:
1, 2, 3 & 4 motor(s): 60 dBA, 63 dBA, 65 dBA, 66 dBA
PHASE 1 1 3 3 3 3 1 3
HERTZ* 60 60 60 60 60 60 50 50
AMPS per MOTOR 3.5 3.5 3.5 3.5 1.4 1.0 3.5 3.5
* Operation at 50 Hz will generate approximately a 17% reduction
in performance.
Note: See sheet KW-237 for heater amp draws/total
load requirements.
Berner reserves the right to alter specifications without prior notice.
Berner International Corporation New Castle, PA 16101 / USA / Telephone (724) 658-3551 / FAX (724) 652-0682 / www.berner.com / airdoors@berner.com