No.: DS-128 Date: December, 2005
Three Speed Electric Heated
ARISTOCRAT
Data Sheet
½ hp motor(s) Helical coil with point suspension of elements for longer lifeFactory installed fan/speed/heat switch  Available single or three phaseGalvanized steel fan wheels & housings Easily replaceable heater elementsAluminum airfoil shaped directional vanes Galvanized steel frameAluminum base frame Thermally protected against overheatingWhite aluminum or stainless steel housingKeyhole slots in backplate for quick wall mountingUL Listed (United States & Canada) OPTIONAL FEATURES
Two year parts warranty  Reduced kW available (consult factory)Crafted with Pride in the USA
MODEL
WHITE
ALUMINUM
MODEL
STAINLESS
STEEL
Noz zle
Width
(in)
Max.
Vel.
(fpm)
Avg.
Outlet
Velocity
(fpm)
Air
Volume
(scfm)
# Motor(s)
@ hp
Power
Rating
(kW)
Outlet
Velocity
Unif. (%)
#
Fans
Electric
Capacity
(kW)
Temp
Rise
°F
Net Wgt. (lbs)
ASR1036E-3X ASR1036E-3X-SS 36" 3500 1965 1812 1 @ ½ .68 79.6 2 10.0 18 52 71
ASR1042E-3X ASR1042E-3X-SS 42" 3500 1716 1752 1 @ ½ .75 78.6 2 10.0 18 55 81
ASR1048E-3X ASR1048E-3X-SS 48" 3500 1504 1882 1 @ ½ .73 54.6 2 10.0 18 56 83
ASR1060E-3X ASR1060E-3X- SS 60" 3500 1225 1817 1 @ ½ .74 27.0 2 10.0 18 63 95
ASR2060E-3X ASR2060E-3X-SS 60" 3500 1805 2726 2 @ ½ 1.18 74.0 3 15.0 18 96 121
ASR2072E-3X ASR2072E-3X-SS 72" 3500 1965 3624 2 @ ½ 1.36 71.9 4 20.0 18 100 140
ALUMINUM STAINLESS STEEL 208/240/1* 208/3 240/3 480/3 600/3** Temp. Rise °F @ kW
ASR1036E-3X ASR1036E-3X-SS 7.5 or 10.0 kW 7.5 or 10.0 kW 7.5 or 10.0 kW 10.0 kW 10.0 kW 14° @ 7.5 kW / 18° @ 10.0 kW
ASR1042E-3X ASR1042E-3X-SS 7.5 or 10.0 kW 7.5 or 10.0 kW 7.5 or 10.0 kW 10.0 kW 10.0 kW 14° @ 7.5 kW / 18° @ 10.0 kW
ASR1048E-3X ASR1048E-3X-SS 7.5 or 10.0 kW 7.5 or 10.0 kW 7.5 or 10.0 kW 10.0 kW 10.0 kW 14° @ 7.5 kW / 18° @ 10.0 kW
ASR1060E-3X ASR1060E-3X-SS 7.5 or 10.0 kW 7.5 or 10.0 kW 7.5 or 10.0 kW 10.0 kW 10.0 kW 14° @ 7.5 kW / 18° @ 10.0 kW
ASR2060E-3X ASR2060E- 3X-SS N/A 15.0 kW 15.0 kW 15.0 kW 15.0 kW 18° @ 15.0 kW
ASR2072E-3X ASR2072E- 3X-SS N/A 15.0 or 20.0 kW 15.0 or 20.0 kW 20.0 kW 20.0 kW 14° @ 15.0 kW / 18° @ 20.0 kW
*Two circuits are required when combined amp draw of motor(s) and heater(s) is greater than 48 amps. **A separate 120/208 or 240/1 circuit required for the motor.
ELECTRIC HEATER DATA
Ship Wgt. (lbs)
MOTOR VOLTAGES/AMP DRAWS
Horsepower 1/2 1/2
Speed 3 3
Volts 120 208/240
Phase 1 1
Hertz** 50/60 50/60
Amps per Motor 7.2 4. 0
**Operation at 50 HZ will generate approxi­mately a 17% reduction in performance.
10.0 k W 48.0* 41.7 27.8 24.1 12.0 10
15.0 kW N/A 62.5* 41.6 36.1 18.0 15.1
20.0 k W N/A 83.3* 55.1* 48.1* 24.1 20.1
*total heater amp draw; two circuits required
Sound level measured 10’ (3m) from the unit in free field: ASR-E 67 dBA
HEATER AMP DRAWS @ kW
208/1 240/1 208/3 240/3 480/3 600/3
Berner reserves the right to alter specifications without prior notice.
Berner International Corporation New Castle, PA 16101 / USA / Telephone (724) 658-3551 / FAX (724) 652-0682 / www.berner.com / airdoors@berner.com
MADE IN U.S.A. ©Copyright, 2005 Berner International Corporation