BERLINER WD-125 User Manual

Pipe gasket
BERLINER WD-125
Multifunctional Wet/Dry Filter Set
Intake pipes
Super-flow weir rated at 3000+ GPH
Dual interchangeable trays for drip and/or 100-micron bag filtration
Reinforced access lids
Protein skimmer return port
Bubble diffusors
Noise reducing water intake chamber
Congratulations with your purchase of this state of the art multifunctional wet/dry filter. The Berliner WD-125 can be operated in 100% berlin mode with four 100-micron filtration bags for superior water quality, 100% wet/dry bio-ball mode, or a combined wet/dry and berlin mode. The filter is complete, and comes with all of the components necessary to run it as a Berlin style system. It also contains drip trays and bio-ball support grids for those who would like to set up a traditional wet/dry. Bio-balls can be purchased separately from your dealer.
Additionally the Berliner WD-125 incorporates two independently operated Simplicity Chemical Reactors to accommodate carbon, phosphate removers, nitrate removers, or any other chemical filter media. Fluidization of media and bypass-free operation ensure ultra-efficient chemical filtration. Overflow holes & bubble diffusing 100-micron bags ensure bubble-free water re-routing when flow rates exceed a particular media's flow capacity.
Bio-ball retaining grids
Dual independent filtration chambers
Dual independent fluidized bed chemical reactors
Unobstructed sump accomodates most submersible pumps and protein skimmers
OWNER'S MANUAL
UNPACKING
1. Carefully lift up the top foam
2. Gently remove unit from box moving it straight up. It may require two people to securely remove filter form box
3. Thoroughly examine the product for any damages and/or defects including cracking or breakage
4. Compare all included components with the components list on the box for completeness
5. Any damages and/or missing components must be reported within 24 hrs of purchase, on-line at www.magnavore.com
INSTALLATION
1. Wipe clean the surface onto which unit will be positioned, making sure that no foreign objects could get trapped underneath the unit
2. Place unit into stand. Adjust if necessary ensuring that filter is leveled
PLUMBING THE DRAIN
Depending on your tank size and number of overflows, you may need to use single intake or double intake installation. A single intake configuration will accommodate aquariums with one overflow and double intake configuration will accommodate a dual overflow aquarium up to 125 gallons. For double intake configuration you will need an additional Drain Kit that can be purchased from your local retailer or on-line at www.magnavore.com
The unit comes with single Drain Kit that contains 4 feet of flexible corrugated hose, 2 cuffs, 2 clamps and a small tube of silicone. To ensure the most quiet filter operation, the hose connecting drain pipe of the aquarium and the filter intake should be adjusted so that it is as short as possible without twisting or kinking. A hose with excess length will sag and cause a noisy flushing effect.
1. Measure the required hose length by placing it between aquarium drain and filter intake pipe forming an inverted "S" shape curve.
2. Cut hose to the measured length with a sharp knife.
3. Fill five thread grooves of one end of hose with a 1/8-inch thick bead of silicone to the level of thread ridges. Additionally put a small bead of silicone around the top rim of pipe.
4. Next screw a cuff counterclockwise onto the siliconed hose end till the end of hose touches the bottom of the narrow part of cuff. Do not over tighten.
5. If necessary, clean up excess silicone from inside and outside of the hose cuff with a paper towel.
6. Repeat steps 3 to 5 for other end of hose.
7. Let hose cure for 24 hrs before installing it. Failure to allow silicone to cure will result in leakage.
8. After curing, attach securely one end of hose to aquarium drain and the other end to filter intake pipe. Install provided hose clamps to fittings. (It may be helpful to soak cuffs briefly in hot water to ease slipping them onto pipe).
If you need to run the filter immediately we recommend that you use a temporary connection while your customized hose is curing.
PLUMBING THE RETURN
1. The lid over sump area has cutouts for return plumbing.
2. Place the pump on bottom of sump. Using a piece of silicone rubber for cushioning is helpful in dissipating pump vibrations. Connect pump outlet to return plumbing according to pump manufacturer instructions.
3. Adjust the flow rate on the pump according to the operational mode; up to 2000 GPH for Berlin mode, up to 1000 GPH for wet/dry mode, and up to 1500 GPH for the combined mode (see operating instructions below).
PROTEIN SKIMMER PLACEMENT
Magnavore Berliner WD-125 filter is designed with large unobstructed sump that can accommodate many protein skimmers. Most types of skimmers placed inside the sump area will require filter to operate with the sump cover removed. Operating filter with uncovered sump will result in some additional evaporation. Check your water level regularly and add when necessary. If an airstone driven skimmer is used or one that has a return port or fitting that is placed high on the skimmer body then the return flow of the skimmer can be routed through one of the 5-inch long bags via the extra grommet on the front top face of the filter.
BERLINER WD-125
Loading...
+ 2 hidden pages