Beretta IDRA DS 200 FI, IDRA DS 300 FI, IDRA DS 430 FI, IDRA DS 550 FI Installation And Operation Manual

Installation and Operation Manual
Solar | Solar storage cylinder
IDRA DS FI
Installation and Operation Manual
EN
This manual, Code 20122522 - Rev. 3 (06/17) comprises 16 pages.
2
RANGE
MODEL CODE
IDRA DS 200 FI 20119552 IDRA DS 300 FI 20119553 IDRA DS 430 FI 20119554 IDRA DS 550 FI 20119555
ACCESSORIES
For a complete list of accessories and details of their com­patibility, refer to the Catalogue.
Dear heating engineer, We would like to congratulate you on having recommended a
B solar storage cylinder unit: a modern product that's
capable of ensuring a high degree of reliability, efciency,
quality and safety. While your technical skills and knowledge will certainly be more than sufcient, this booklet contains all the informa­tion that we have deemed necessary for the device's cor­rect and easy installation.
Thank you again, and keep up the good work,
Beretta
CONFORMITY
The B solar heaters comply with DIN 4753-3 and UNI EN 12897.
ENGLISH
CONTENTS
The following symbols are used in this manual:
b
CAUTION! =
Identies actions that require caution
and adequate preparation.
a
STOP! =
Identies actions that you MUST NOT do.
This manual, Code
- Rev. comprises pages.
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . 3
1 General Safety Information . . . . . . . . . . . . . . . . . 3
2 Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3 Description of the appliance . . . . . . . . . . . . . . . . 4
4 Safety and control devices . . . . . . . . . . . . . . . . . 4
5 Identication . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
6 System layout. . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
7 Technical specications . . . . . . . . . . . . . . . . . . . 6
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
8 Unpacking the product . . . . . . . . . . . . . . . . . . . . 8
9 Access to the solar station. . . . . . . . . . . . . . . . . . 8
10 Place of installation . . . . . . . . . . . . . . . . . . . . . . . 8
11 Installation in older systems and systems
requiring modernisation. . . . . . . . . . . . . . . . . . . . 8
12 Water quality requirements . . . . . . . . . . . . . . . . . 8
13 Water connections . . . . . . . . . . . . . . . . . . . . . . . . 9
14 Typical water system schematics . . . . . . . . . . . 10
15 Wiring diagrams. . . . . . . . . . . . . . . . . . . . . . . . . 10
16 Electrical connections . . . . . . . . . . . . . . . . . . . . 10
17 System ushing . . . . . . . . . . . . . . . . . . . . . . . . . 12
18 System lling cock . . . . . . . . . . . . . . . . . . . . . . . 13
19 Device cleaning and maintenance . . . . . . . . . . 13
COMMISSIONING AND MAINTENANCE . . . . . . . . . 14
20 Interventions on the hydraulic system . . . . . . . . 14
21 Recycling and disposal . . . . . . . . . . . . . . . . . . . 14
END USER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
22 Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
23 Temporary shutdown . . . . . . . . . . . . . . . . . . . . . 15
24 Preparing for extended periods of disuse . . . . . 15
25 External maintenance . . . . . . . . . . . . . . . . . . . . 15
3
GENERAL INFORMATION
1 GENERAL SAFETY INFORMATION
b
Check that the product is complete, undamaged and
as ordered as soon as you receive it. Report any dis­crepancies or damage to the B dealer who sold it.
b
This product must be installed by a legally qualied heating engineer. On completion of the installation,
the installer must issue the owner with a declaration
of conformity conrming that the installation has been
completed to the highest standards in compliance with the instructions provided by
B in this instruc-
tion manual, and that it conforms to all applicable laws and standards.
b
This product must only be used for the purpose
for which it is designed and made, as specied by
B. B declines all responsibility, contractual or
other, for damage to property or injury to persons or animals caused by improper installation, adjustment, maintenance or use.
b
The product must be serviced at least once a year. Servicing must be arranged in advance with the
B Technical Assistance Centre.
b
All servicing and repairs must be performed by a
qualied heating engineer.
b
If water leaks from the storage cylinder, turn off the
water supply and contact B’s Technical Assis­tance Centre or a qualied heating engineer imme­diately.
b
If the product is not going to be used for an extended period of time, contact the manufacturer’s Technical Assistance Centre to have at least the following oper­ations performed:
- Close the shut-off cocks for the domestic hot water circuit
- Shut down the boiler connected to the storage cylin­der as instructed in its own manual
- Switch the storage cylinder OFF at the control panel
(if tted) and at the mains power switch
- Drain the central heating circuit and domestic hot
water circuit if there is any risk of freezing.
b
This instruction manual is an integral part of the prod­uct. It must be kept safe and must ALWAYS accom­pany the product, even if it is sold to another owner or transferred to another user or to another installation. If you lose this manual, order a replacement immedi­ately. Keep the product purchase documents to be presented to the
B authorised Technical Assis-
tance Centre to request a service call under warranty.
b
Size the solar expansion tank so as to ensure com­plete absorption of the expansion of the uid con-
tained within the system, with reference to the prevail­ing regulations on the matter. In particular, consider uid characteristics, considerable uctuation of ser­vice temperature and vapour that might be generated
during solar collector stagnation stage. Proper size of expansion tank ensures setting off of all volume changes of the heat transfer uid, avoiding excessive pressure increase. Limited pressure changes avoid
reaching safety valve opening pressure and the con-
sequent uid drainage.
2 PRECAUTIONS
The operation of any appliance that uses electrical power demands that a number of fundamental safety precautions be respected. In particular:
a
Never attempt to install the system without using suit­able personal protection equipment and without fol-
lowing all applicable occupational safety standards.
a
It is forbidden to touch the device while barefoot or with wet or moist body parts.
a
It is forbidden to perform any technical or cleaning operations before having disconnected the device from its electrical power supply, by setting the sys­tem's main switch to "off".
a
It is forbidden to pull, detach, or twist the electrical cables protruding from the device, even if it is discon­nected from its electrical power supply.
a
Do not expose the storage cylinder to the elements. It is not designed for use outdoors.
a
If solar plant pressure decreases, it is forbidden to
top up with only water as there is a danger of freezing
and overheating.
a
Do not use connections or safety devices or ttings
(expansion vessels, pipes, insulation) that are not specically designed and tested for use in solar wa­ter heating systems.
a
Do not allow children or inrm persons to operate the
system unsupervised.
a
Do not dispose of packaging material into the envi­ronment, or leave it within the reach of children, since it can become a potential hazard. Dispose of packag­ing material in compliance with applicable legislation.
a
It is forbidden to use the pipes for handling.
General information
GENERAL INFORMATION
4
3 DESCRIPTION OF THE
APPLIANCE
B
IDRA DS FI
double-coil solar boilers, with pre-tted
solar station, are available in four different models, can be integrated in solar systems for the production of domestic hot water and can be easily used in solar systems where
B boilers or heating units serve as an integration.
The most important technical features of these solar stor­age cylinders are:
- the accurate study of tank and coil geometry
- internal glazing, bacteriologically inert, to ensure the max. hygiene of treated water, reduce limescale de-
posits and make cleaning operations easier
- insulation made of expanded polyurethane free from
CFC (chlorouorocarbons)
- a ange for easy cleaning and maintenance of the anti-corrosion magnesium anode
- solar station enclosed in an insulating casing in EPP (Polypropylene foam), used also for solar system
washing, lling and emptying as well as for circulator
removal
The main components of the solar station are:
- high-efciency circulator with variable speed (al­ready hard-wired)
- solar regulator (already hard-wired), as indicated in paragraph "Safety and control devices"
- shut-off valves as non-return valves
- thermometers
- pressure gauge
- tting for connection to a solar expansion tank
- suitable safety device, as indicated in paragraph " Safety and control devices"
4 SAFETY AND CONTROL DEVICES
Equipment safety and setting are achieved thanks to:
- Safety valve with trigger pressure set at 6 bar;
- Solar Regulator for circulator management/adjust­ment. It manages 9 system diagrams that can be se-
lected. Refer to the specic manual for further details.
5 IDENTIFICATION
The B
IDRA DS FI
solar heaters can be identied by:
Data plate
This lists the technical specications and performance
of the product.
SOLARBOILER
Modell Herstell. Nr.
Artikel Nr.
Baujahr
Maximaler Boilerbetriebsdruck
Anschlussspannung
bar
V-Hz
Boilerfassungvermögen
l
T067659ED02
ERDUNG OBLIGATORISCH - OBLIGATORY GROUND CONNECTION
W
Elektrischer Leistung
m
2
m
2
Leistungsaufnahme obere Rohrschlange
kW
Erzeugung von Brauchwasser
l/1'
[Primärkreislauftemperatur T=80°C]
SOLAR STORAGE CYLINDER
Model Serial number
Code
Year
Power absorbed by top coil (T° primary 80°C)
Domestic Hot Water production - top coil
Maximum working pressure of storage cylinder
Storage cylinder capacity
Electrical consumption
Power supply
obere Rohrschlange[ 35°C]
T
Austauschoberfläche obere Rohrschlange Top coil heat exchange surface area
Austauschoberfläche untere Rohrschlange Bottom coil heat exchange surface area
Austauschoberfläche untere Rohrschlange Bottom coil heat exch. surf. area
Serial number
Model
kW
Power absorbed by top coil
Herstell. Nr.
Leistungsaufnahme obere Rohrschlange
Modell
m
2
Beretta Caldaie Via Risorgimento, 1323900 Lecco (LC)
Serial number plate
This species the serial number and model.
b
If these plates or any other means of clearly iden­tifying the product are defaced, removed or lost, proper installation and servicing may be rendered
difcult.
GENERAL INFORMATION
5
6 SYSTEM LAYOUT
1
7
6
5
2
4
3
9
13
11
10
1
R
2
3
M
UAC
EAF
SB
SV
VE
RB
MB
4
5
6
7
8
12
Mo
P
STORAGE CYLINDER
1
Storage cylinder
2
Top coil
3
Preset for lifting handles (accessory) and/or device grounding point
4
Bottom coil
5
Flange for heater inspection
6
Insulation
7
Cover
P
Socket
Mo
Guide
UAC
Domestic hot water outlet
EAF
Domestic cold water inlet
SB
Storage cylinder drain
SOLAR STATION
1
Return Valve (solar plant return) with built-in non-re­turn valve
2
Delivery Valve (solar plant delivery) with built-in non-return valve
3
Outlet temperature gauge
4
Return temperature gauge
5
Insulation
6
Solar controller
7
Display
8
Multidirectional joystick
9
Tap A for system lling/draining
10
Pump
11
Pressure gauge
12
Tap B for system lling/draining
13
Safety valve (6 bar)
M
Solar circuit outlet. Inlet of heat transfer uid coming
from solar collector.
R
Solar circuit return. Outlet of heat transfer uid to-
wards solar collector.
MB
Heater delivery. Outlet of heat transfer uid towards
solar heater.
RB
Heater return. Inlet of heat transfer uid coming from
solar heater.
SV
Safety valve drain
VE
Expansion tank tting
Loading...
+ 11 hidden pages