models, with outputs of 26, 30 and 35kW
(combi and only heating versions), and
conventional flue models, with outputs
of 24 and 28kW (combi and only heating
versions).
Efficiency ★★★, the highest according
to European Directive EEC 92/42, on
room-sealed models (C.S.I. and R.S.I.).
Exclusive MIX system: continuous
electronic air/gas modulation, ensuring
high efficiency in any operation mode (on
room-sealed models: C.S.I. and R.S.I.).
“Survivor” function in DHW mode,
allowing the boiler, in the event of failure
of the DHW NTC probe, to continue to
operate.
Reduced waiting time for DHW supply
thanks to pre-heating function (on
combi models).
Clever and intuitive control panel with
backlit display.
S.A.R.A. and S.A.R.A. Booster systems:
automatic temperature control in heating
mode (see dedicated section).
Built-in climatic thermoregulation that can
be activated through the external probe
(as option) for a high comfort level inside
the house.
3-speed circulator with 5 metres head (6
metres head on the 35 kW model).
Electrical protection IPX5D.
Hydraulic connections, gas and DHW taps
supplied as standard.
EXCLUSIVE can be converted to LPG
through specific LPG kit (as option).
The lower connections cover, supplied
as standard, allows to hide hydraulic
connections, ensuring a tidy installation.
The simplicity of comfort
EXCLUSIVE is characterized by an
essential and stylish design.
The control panel is located under
a modern flap from which appears
a wide LCD display that shows all
information about the boiler status.
By simply rotating two knobs, it is
possible to set CH and DHW
temperatures. By simply pushing a
button, you can choose your comfort
level and activate the Easy Filling
system, when the boiler requires it.
The control panel also integrates the
thermoregulation function (external
probe as option).
Adjustment of
the CH set-point
Flame detector
Circulator
anti-blocking cycles
System
pressure display
ON/OFF/reset
Winter/Summer selection
and comfort functions
“Survivor” function
Electrical protection
IPX5D
CH/DHW
temperatures display
Adjustment of the
DHW set-point
Activation of the
Easy Filling system
Info
Note: this display refers to combi models
Page 3
Standard Efficiency Wall-Hung BoilersResidential Heating
Maximum comfort for all climate conditions
combi modelsonly heating models
WinterSummer
Central heating ON and domestic hot water
activated.
In this mode S.A.R.A. system (Automatic
Temperature Control) can be enabled by
positioning the water temperature between
55°C and 65°C.
This setting is recommended in spring and
autumn, or in areas or periods in which
winter is not hard.
Winter
comfort
Faster heating and domestic hot water.
In this mode S.A.R.A. Booster system
(Automatic Temperature Control) is enabled.
The domestic hot water Pre-heating
function is activated, thus allowing a quicker
DHW delivery.
This setting is recommended in cold areas,
or during the hard winter periods.
Central heating OFF and domestic hot water
activated.
Summer
comfort
Central heating OFF and optimum stabilization of DHW temperature.
The burner is continuously kept on at the
minimum power during the small DHW
demands, avoiding in this way that the
burner switches off every time when the
domestic water from the net is slightly
warm. This feature allows an optimum
temperature stabilization of DHW.
Winter
Central heating ON (domestic hot water
available only if an external tank is
connected).
In this mode S.A.R.A. Booster system
(Automatic Temperature Control) is
activated.
Summer
Central heating OFF (domestic hot water
available only if an external tank is
connected).
Easy Filling
On combi models is activated the innovative Easy Filling system:
New
The first boiler with a new semi-automatic
filling system.
Safe
Thanks to a double control of the pressure,
the filling is automatically stopped if it
detects any leak in the system, so as not to
worsen the loss.
On only heating models, filling is done through an external tap.
Smart
It alerts you when you need to fill the
system before the pressure drops below the
lockout level.
Easy
Filling the system has never been so simple:
one push of the button is enough.
Page 4
Exclusive
10’
Time
starting room
temperature
20’
30’
40’T1T2T3
desired room
temperature
set
ow temperature:
60 °C
65 °C
70 °C
75 °C
T °C
Efciency %
100
90
80
10
1030 406080100
Thermal load %
Average
thermal load
S.A.R.A. and S.A.R.A. Booster systems
S.A.R.A. and S.A.R.A. Booster systems
(Automatic Temperature Control), patented
by Beretta, are designed to provide a high
comfort level in the central heating mode,
allowing you to reach the desired room
temperature more rapidly.
When there is a demand for heating,
the appliance will automatically raise the
heating flow temperature every 20 minutes
with S.A.R.A. or every 10 minutes with
S.A.R.A. Booster, by 5 °C steps (see
diagram).
When the heating request has been
satisfied, the boiler automatically restores
the flow temperature to the setted value,
thus allowing a better temperature stability
of the radiators.
EXCLUSIVE integrates on all combi models
both systems, providing maximum comfort in every climate condition.
S.A.R.A. Booster is automatically activated
by selecting WINTER COMFORT on the
control panel. This setting is recommended
in cold areas, or during the hard winter
periods.
S.A.R.A. is activated by selecting WINTER
on the control panel and by setting the
temperature of the central heating circuit
between 55°C and 65°C. This setting is
recommended in spring and autumn, or in
areas or periods when winter is not hard.
On the only heating models, S.A.R.A.
Booster is always activated in WINTER
mode.
Flow temperature and Room temperature
with S.A.R.A. Booster system (WINTER
COMFORT)
Flow temperature and Room temperature
with S.A.R.A. system (WINTER)
The MIX system
All the room-sealed models of EXCLUSIVE
range are equipped with the “MIX system”,
that maintains the air/gas ratio always
optimal, by controlling the fan speed.
In this way EXCLUSIVE ensures high
efficiency performance in each mode of
operation, with a consequent reduction in
the consumption of gas and electricity.
Moreover, thanks to the “MIX system”,
EXCLUSIVE boilers fit flues of different
lengths for a maximum flexibility of
installation.
Flow temperature and Room temperature
without S.A.R.A. or S.A.R.A. BOOSTER
systems
Exclusive Mix
Exclusive
Page 5
Standard Efficiency Wall-Hung BoilersResidential Heating
The technology
112
1
Double air inlet for twin system
2
Flue gas analysis
3
13
Variable fan speed
3
4
Circulation pump with anti-blocking function
5
3-way valve with anti-blocking function
6
Analogic hydrometer and filling system manual tap
7
Built-in climatic thermoregulation through the
external probe (as option)
8
Electronic board with frost protection
9
IPX5D electrical protection
10
4
5
6
12
11
10
Automatic by-pass on the heating circuit
Hydraulic group with quick connectors and front
11
access components
12
DHW plate heat-exchanger with possibility of preheating
7
8
Note: this picture refers to combi models
9
13
Air/gas combustion system (on MIX CSI and MIX RSI
models)
Climatic Thermoregulation: more comfort and saving
The built-in climatic Thermoregulation is a
standard feature for the whole EXCLUSIVE
range. Your installer just has to connect
the external sensor (optional) to EXCLUSIVE
electronic board, to enable this function.
The Thermoregulation function adjusts the
boiler operation according to the external
climate changes in order to optimize comfort
and maximize saving.
Standard Efficiency Wall-Hung BoilersResidential Heating
Technical data (conventional flue models)
C combi model (CH + DHW)
SPECIFICATIONS AND MODELS
CH nominal heat inputkW26,7031,9031,90
CH nominal heat output (80°-60° C)kW23,9828,7128,71
CH minimum heat inputkW10,7014,0014,00
CH minimum heat output (80°-60° C)kW9,1411,9311,93
DHW nominal inputkW26,7031,9031,90
DHW maximum output*kW23,9828,7128,71
DHW minimum inputkW8,308,708,70
DHW minimum output*kW7,097,417,41
Efficiency at max nominal output (80°-60° C)%89,890,090,0
Efficiency at min nominal output (80°-60° C)%85,485,285,2
Efficiency at partial load 30% (47°C return)%89,589,589,5
NOx class222
Max power consumptionW888888
Power supplyV/Hz230/50230/50230/50
Electrical protectionIPX5DX5DX5D
CENTRAL HEATING
Maximum pressure - temperaturebar - °C3 - 903 - 903 - 90
Minimum pressure for standard operationbar0,25 ÷ 0,450,25 ÷ 0,450,25 ÷ 0,45
Adjustable CH water temperature range°C40/8040/8040/80
CH expansion vessel pre-charge/Capacitybar/l1/81/81/8
DHW
Maximum pressurebar66Minimum pressurebar0,150,15DHW production ∆T=25°Cl/min13,716,5DHW production ∆T=30°Cl/min11,513,7DHW production ∆T=35°Cl/min9,811,8Hot water minimum flow ratel/min22Adjustable hot water temperature range°C35 - 6035 - 60-
Boiler dimensions (HxWxD)mm740x400x332740x450x332740x450x332
Net weightkg303332
Certified gas types
Available gas versionsNG, LPG***NG, LPG***NG, LPG***
A conventional flueR heating only model
EXCLUSIVE
24 C.A.I.
II2H3+
I3B/P
EXCLUSIVE
28 C.A.I.
II2H3+
I3B/P
I ionisation flame control
EXCLUSIVE
28 R.A.I.**
II2H3+
I3B/P
* average among the different functioning conditions in DHW
** values of DHW function are to be considered only in case of connection with an external tank
*** LPG version available with conversion kit (supplied as optional).
Page 8
Standard Efficiency Wall-Hung BoilersResidential Heating
Technical data (room-sealed models)
C combi model (CH + DHW)
S room-sealedR heating only model
I ionisation flame control
EXCLUSIVE
SPECIFICATIONS AND MODELS
CH nominal heat inputkW28,8033,2037,8033,2037,80
CH nominal heat output (80°-60° C)kW26,2130,3835,3130,3835,31
CH minimum heat inputkW8,509,809,959,809,95
CH minimum heat output (80°-60° C)kW7,708,869,188,869,18
DHW nominal inputkW28,8033,2037,8033,20**37,80**
DHW maximum output*kW26,2130,3835,3130,38**35,31**
DHW minimum inputkW8,509,809,959,80**9,95**
DHW minimum output*kW7,708,869,188,86**9,18**
Efficiency at max nominal output (80°-60° C)%91,0 - 90,691,5 - 90,493,4 - 92,391,5 - 90,493,4 - 92,3
Efficiency at min nominal output (80°-60° C)%91,992,294,592,294,5
Efficiency at partial load 30% (47°C return)23333
NOx classW120150160150160
Max power consumptionV/Hz230/50230/50230/50230/50230/50
Power supplyIPX5DX5DX5DX5DX5D
Electrical protection
Maximum pressure - temperaturebar - °C3 - 903 - 903 - 903 - 903 - 90
Minimum pressure for standard operationbar0,25 ÷ 0,450,25 ÷ 0,450,25 ÷ 0,450,25 ÷ 0,450,25 ÷ 0,45
Adjustable CH water temperature range°C40/80 40/80 40/80 40/80 40/80
CH expansion vessel pre-charge/Capacitybar/l1/81/81/101/81/10
DHW
Maximum pressurebar666-Minimum pressurebar0,150,150,15-DHW production ∆T=25°C/30°C/35°Cl/min15,0/12,5/10,7 17,4/14,5/12,4 20,2/16,9/14,5-Hot water minimum flow ratel/min222-Adjustable hot water temperature range°C35 - 6035 - 6035 - 60--
Diametermm60-10060-10060-10060-10060-100
Maximum lengthm3,403,402,003,402,00
Loss for a 45°/90° bendm1/1,51/1,51/1,51/1,51/1,5
Diametermm80-12580-12580-12580-12580-125
Maximum lengthm7,617,617,614,264,26
Loss for a 45°/90° bendm1,35/2,21,35/2,21,35/2,21,35/2,21,35/2,2
TWIN PIPES
Diametermm8080808080
Maximum lengthm15 + 1514 + 146 + 614 + 146 + 6
Loss for a 45°/90° bendm1,2/1,71,2/1,71,2/1,71,2/1,71,2/1,7
DIMENSIONS, WEIGTH, GAS
Boiler dimensions (HxWxD)mm740x400x332740x450x332780x500x332740x450x332780x500x332
Net weightkg3436433541
Certified gas types
Available gas versionsNG, LPG***NG, LPG***NG, LPG***NG, LPG***NG, LPG***
* average among the different functioning conditions in DHW ** values of DHW function are to be considered only in case of connection with an external tank
*** LPG version available with conversion kit (supplied as optional).
In order to improve its product, Beretta reserves the right to modify the characteristics and
information shown in this manual at any time and without advance warning.
This brochure, therefore, cannot be considered as contractually binding on third parties.