Beretta Exclusive (range) DATA SHEET

Page 1
Exclusive
Standard Efficiency Wall-Hung Boilers
Residential Heating
Page 2
Exclusive
EXCLUSIVE represents Beretta top of the
range wall-hung boiler.
Its wide offer includes both room-sealed
models, with outputs of 26, 30 and 35kW (combi and only heating versions), and conventional flue models, with outputs of 24 and 28kW (combi and only heating versions).
Efficiency ★★★, the highest according
to European Directive EEC 92/42, on room-sealed models (C.S.I. and R.S.I.).
Exclusive MIX system: continuous
electronic air/gas modulation, ensuring high efficiency in any operation mode (on room-sealed models: C.S.I. and R.S.I.).
“Survivor” function in DHW mode,
allowing the boiler, in the event of failure of the DHW NTC probe, to continue to operate.
Reduced waiting time for DHW supply
thanks to pre-heating function (on combi models).
Clever and intuitive control panel with
backlit display.
S.A.R.A. and S.A.R.A. Booster systems:
automatic temperature control in heating mode (see dedicated section).
Built-in climatic thermoregulation that can
be activated through the external probe (as option) for a high comfort level inside the house.
3-speed circulator with 5 metres head (6
metres head on the 35 kW model). Electrical protection IPX5D. Hydraulic connections, gas and DHW taps
supplied as standard. EXCLUSIVE can be converted to LPG
through specific LPG kit (as option). The lower connections cover, supplied
as standard, allows to hide hydraulic
connections, ensuring a tidy installation.
The simplicity of comfort
EXCLUSIVE is characterized by an essential and stylish design. The control panel is located under a modern flap from which appears a wide LCD display that shows all information about the boiler status. By simply rotating two knobs, it is possible to set CH and DHW temperatures. By simply pushing a button, you can choose your comfort level and activate the Easy Filling system, when the boiler requires it. The control panel also integrates the thermoregulation function (external probe as option).
Adjustment of the CH set-point
Flame detector
Circulator anti-blocking cycles
System pressure display
ON/OFF/reset
Winter/Summer selection and comfort functions
“Survivor” function
Electrical protection IPX5D
CH/DHW
temperatures display
Adjustment of the
DHW set-point
Activation of the
Easy Filling system
Info
Note: this display refers to combi models
Page 3
Standard Efficiency Wall-Hung Boilers Residential Heating
Maximum comfort for all climate conditions
combi models only heating models
Winter Summer
Central heating ON and domestic hot water activated. In this mode S.A.R.A. system (Automatic Temperature Control) can be enabled by positioning the water temperature between 55°C and 65°C. This setting is recommended in spring and autumn, or in areas or periods in which winter is not hard.
Winter comfort
Faster heating and domestic hot water. In this mode S.A.R.A. Booster system (Automatic Temperature Control) is enabled. The domestic hot water Pre-heating function is activated, thus allowing a quicker DHW delivery. This setting is recommended in cold areas, or during the hard winter periods.
Central heating OFF and domestic hot water activated.
Summer comfort
Central heating OFF and optimum stabilization of DHW temperature. The burner is continuously kept on at the minimum power during the small DHW demands, avoiding in this way that the burner switches off every time when the domestic water from the net is slightly warm. This feature allows an optimum temperature stabilization of DHW.
Winter
Central heating ON (domestic hot water available only if an external tank is connected). In this mode S.A.R.A. Booster system (Automatic Temperature Control) is activated.
Summer
Central heating OFF (domestic hot water available only if an external tank is connected).
Easy Filling
On combi models is activated the innovative Easy Filling system:
New
The first boiler with a new semi-automatic filling system.
Safe
Thanks to a double control of the pressure, the filling is automatically stopped if it detects any leak in the system, so as not to worsen the loss.
On only heating models, filling is done through an external tap.
Smart
It alerts you when you need to fill the system before the pressure drops below the lockout level.
Easy
Filling the system has never been so simple: one push of the button is enough.
Page 4
Exclusive
10’
Time
starting room
temperature
20’
30’
40’T1 T2 T3
desired room
temperature
set ow temperature:
60 °C
65 °C
70 °C
75 °C
T °C
Efciency %
100
90
80
10
10 30 40 60 80 100
Thermal load %
Average thermal load
S.A.R.A. and S.A.R.A. Booster systems
S.A.R.A. and S.A.R.A. Booster systems (Automatic Temperature Control), patented by Beretta, are designed to provide a high comfort level in the central heating mode, allowing you to reach the desired room temperature more rapidly. When there is a demand for heating, the appliance will automatically raise the heating flow temperature every 20 minutes
with S.A.R.A. or every 10 minutes with S.A.R.A. Booster, by 5 °C steps (see
diagram).
When the heating request has been satisfied, the boiler automatically restores the flow temperature to the setted value, thus allowing a better temperature stability of the radiators. EXCLUSIVE integrates on all combi models both systems, providing maximum comfort in every climate condition. S.A.R.A. Booster is automatically activated by selecting WINTER COMFORT on the control panel. This setting is recommended
in cold areas, or during the hard winter periods. S.A.R.A. is activated by selecting WINTER on the control panel and by setting the temperature of the central heating circuit between 55°C and 65°C. This setting is recommended in spring and autumn, or in areas or periods when winter is not hard. On the only heating models, S.A.R.A. Booster is always activated in WINTER mode.
Flow temperature and Room temperature with S.A.R.A. Booster system (WINTER
COMFORT)
Flow temperature and Room temperature with S.A.R.A. system (WINTER)
The MIX system
All the room-sealed models of EXCLUSIVE range are equipped with the “MIX system”, that maintains the air/gas ratio always optimal, by controlling the fan speed. In this way EXCLUSIVE ensures high efficiency performance in each mode of operation, with a consequent reduction in the consumption of gas and electricity. Moreover, thanks to the “MIX system”, EXCLUSIVE boilers fit flues of different lengths for a maximum flexibility of installation.
Flow temperature and Room temperature without S.A.R.A. or S.A.R.A. BOOSTER systems
Exclusive Mix
Exclusive
Page 5
Standard Efficiency Wall-Hung Boilers Residential Heating
The technology
1 12
1
Double air inlet for twin system
2
Flue gas analysis
3
13
Variable fan speed
3
4
Circulation pump with anti-blocking function
5
3-way valve with anti-blocking function
6
Analogic hydrometer and filling system manual tap
7
Built-in climatic thermoregulation through the external probe (as option)
8
Electronic board with frost protection
9
IPX5D electrical protection
10
4
5 6
12
11
10
Automatic by-pass on the heating circuit
Hydraulic group with quick connectors and front
11
access components
12
DHW plate heat-exchanger with possibility of pre­heating
7 8
Note: this picture refers to combi models
9
13
Air/gas combustion system (on MIX CSI and MIX RSI models)
Climatic Thermoregulation: more comfort and saving
The built-in climatic Thermoregulation is a standard feature for the whole EXCLUSIVE range. Your installer just has to connect the external sensor (optional) to EXCLUSIVE electronic board, to enable this function.
The Thermoregulation function adjusts the boiler operation according to the external climate changes in order to optimize comfort and maximize saving.
N
Page 6
Exclusive
Technical drawings
EXCLUSIVE 24-28 C.A.I. (conventional flue, combi boilers) EXCLUSIVE 28 R.A.I. (conventional flue, heating only boilers)
332
203,5
740
water - gas
65
163,5
R F G O I(C.A.I.) R F G TR TF(R.A.I.)
A
B B
65 120 60 55
24 C.A.I. 400 180 28 C.A.I. 450 205 28 R.A.I. 450 205
707,5
A B
KEY:
System: Return R/Flow F/Tank Return TR/
Tank Flow TF/Gas G
Domestic water: Inlet I/Outlet O
View from above
200 (24 CAI)
225 (28 CAI - RAI)
200 (24 CAI)
225 (28 CAI - RAI)
203,5
EXCLUSIVE 26-30-35 MIX C.S.I. (room-sealed, combi boilers) EXCLUSIVE 30-35 MIX R.S.I. (room-sealed, heating only boilers)
145 (26-30kW) 162 (35kW)
163,5
332
740 (26-30kW) - 780 (35kW)
water - gas
65
R F G O I(C.S.I.) R F G TR TF(R.S.I.)
A
B B
65 120 60 55
26 MIX C.S.I. 400 180 30 MIX C.S.I. 450 205 30 MIX R.S.I. 450 205 35 MIX C.S.I. 500 230 35 MIX R.S.I. 500 230
707,5
A B
View from above
26 - 30 kW
90 (26 kW)
115 (30 kW)
98 98
35 kW
140 110 110 140
90 (26 kW)
115 (30 kW)
145
162
For all flueing configurations please refer to the current local and national rules.
B B
131
26 MIX C.S.I. 180 30 MIX C.S.I. 205 30 MIX R.S.I. 205 35 MIX C.S.I. 230 35 MIX R.S.I. 230
101
92
B
B B
Page 7
Standard Efficiency Wall-Hung Boilers Residential Heating
Technical data (conventional flue models)
C combi model (CH + DHW)
SPECIFICATIONS AND MODELS
CH nominal heat input kW 26,70 31,90 31,90 CH nominal heat output (80°-60° C) kW 23,98 28,71 28,71 CH minimum heat input kW 10,70 14,00 14,00 CH minimum heat output (80°-60° C) kW 9,14 11,93 11,93 DHW nominal input kW 26,70 31,90 31,90 DHW maximum output* kW 23,98 28,71 28,71 DHW minimum input kW 8,30 8,70 8,70 DHW minimum output* kW 7,09 7,41 7,41 Efficiency at max nominal output (80°-60° C) % 89,8 90,0 90,0 Efficiency at min nominal output (80°-60° C) % 85,4 85,2 85,2 Efficiency at partial load 30% (47°C return) % 89,5 89,5 89,5 NOx class 2 2 2 Max power consumption W 88 88 88 Power supply V/Hz 230/50 230/50 230/50 Electrical protection IP X5D X5D X5D
CENTRAL HEATING
Maximum pressure - temperature bar - °C 3 - 90 3 - 90 3 - 90 Minimum pressure for standard operation bar 0,25 ÷ 0,45 0,25 ÷ 0,45 0,25 ÷ 0,45 Adjustable CH water temperature range °C 40/80 40/80 40/80 CH expansion vessel pre-charge/Capacity bar/l 1/8 1/8 1/8
DHW
Maximum pressure bar 6 6 ­Minimum pressure bar 0,15 0,15 ­DHW production ∆T=25°C l/min 13,7 16,5 ­DHW production ∆T=30°C l/min 11,5 13,7 ­DHW production ∆T=35°C l/min 9,8 11,8 ­Hot water minimum flow rate l/min 2 2 ­Adjustable hot water temperature range °C 35 - 60 35 - 60 -
CONNECTIONS
CH flow - return/Gas Ø 3/4" 3/4" 3/4" DHW inlet - outlet Ø 1/2" 1/2" 3/4”**
FLUE PIPES
Diameter mm 130 140 140
DIMENSIONS, WEIGTH, GAS
Boiler dimensions (HxWxD) mm 740x400x332 740x450x332 740x450x332 Net weight kg 30 33 32
Certified gas types
Available gas versions NG, LPG*** NG, LPG*** NG, LPG***
A conventional flueR heating only model
EXCLUSIVE
24 C.A.I.
II2H3+
I3B/P
EXCLUSIVE
28 C.A.I.
II2H3+
I3B/P
I ionisation flame control
EXCLUSIVE
28 R.A.I.**
II2H3+
I3B/P
* average among the different functioning conditions in DHW ** values of DHW function are to be considered only in case of connection with an external tank *** LPG version available with conversion kit (supplied as optional).
Page 8
Standard Efficiency Wall-Hung Boilers Residential Heating
Technical data (room-sealed models)
C combi model (CH + DHW)
S room-sealedR heating only model
I ionisation flame control
EXCLUSIVE
SPECIFICATIONS AND MODELS
CH nominal heat input kW 28,80 33,20 37,80 33,20 37,80 CH nominal heat output (80°-60° C) kW 26,21 30,38 35,31 30,38 35,31 CH minimum heat input kW 8,50 9,80 9,95 9,80 9,95 CH minimum heat output (80°-60° C) kW 7,70 8,86 9,18 8,86 9,18 DHW nominal input kW 28,80 33,20 37,80 33,20** 37,80** DHW maximum output* kW 26,21 30,38 35,31 30,38** 35,31** DHW minimum input kW 8,50 9,80 9,95 9,80** 9,95** DHW minimum output* kW 7,70 8,86 9,18 8,86** 9,18** Efficiency at max nominal output (80°-60° C) % 91,0 - 90,6 91,5 - 90,4 93,4 - 92,3 91,5 - 90,4 93,4 - 92,3 Efficiency at min nominal output (80°-60° C) % 91,9 92,2 94,5 92,2 94,5 Efficiency at partial load 30% (47°C return) 2 3 3 3 3 NOx class W 120 150 160 150 160 Max power consumption V/Hz 230/50 230/50 230/50 230/50 230/50 Power supply IP X5D X5D X5D X5D X5D Electrical protection Maximum pressure - temperature bar - °C 3 - 90 3 - 90 3 - 90 3 - 90 3 - 90 Minimum pressure for standard operation bar 0,25 ÷ 0,45 0,25 ÷ 0,45 0,25 ÷ 0,45 0,25 ÷ 0,45 0,25 ÷ 0,45 Adjustable CH water temperature range °C 40/80 40/80 40/80 40/80 40/80 CH expansion vessel pre-charge/Capacity bar/l 1/8 1/8 1/10 1/8 1/10
DHW
Maximum pressure bar 6 6 6 - ­Minimum pressure bar 0,15 0,15 0,15 - ­DHW production ∆T=25°C/30°C/35°C l/min 15,0/12,5/10,7 17,4/14,5/12,4 20,2/16,9/14,5 - ­Hot water minimum flow rate l/min 2 2 2 - ­Adjustable hot water temperature range °C 35 - 60 35 - 60 35 - 60 - -
CONNECTIONS
CH flow - return/Gas Ø 3/4" 3/4" 3/4" 3/4" 3/4" DHW inlet - outlet Ø 1/2" 1/2" 1/2” 3/4”** 3/4”**
CONCENTRIC PIPES
Diameter mm 60-100 60-100 60-100 60-100 60-100 Maximum length m 3,40 3,40 2,00 3,40 2,00 Loss for a 45°/90° bend m 1/1,5 1/1,5 1/1,5 1/1,5 1/1,5 Diameter mm 80-125 80-125 80-125 80-125 80-125 Maximum length m 7,61 7,61 7,61 4,26 4,26 Loss for a 45°/90° bend m 1,35/2,2 1,35/2,2 1,35/2,2 1,35/2,2 1,35/2,2
TWIN PIPES
Diameter mm 80 80 80 80 80 Maximum length m 15 + 15 14 + 14 6 + 6 14 + 14 6 + 6 Loss for a 45°/90° bend m 1,2/1,7 1,2/1,7 1,2/1,7 1,2/1,7 1,2/1,7
DIMENSIONS, WEIGTH, GAS
Boiler dimensions (HxWxD) mm 740x400x332 740x450x332 780x500x332 740x450x332 780x500x332 Net weight kg 34 36 43 35 41
Certified gas types
Available gas versions NG, LPG*** NG, LPG*** NG, LPG*** NG, LPG*** NG, LPG***
* average among the different functioning conditions in DHW ** values of DHW function are to be considered only in case of connection with an external tank *** LPG version available with conversion kit (supplied as optional).
26 MIX C.S.I.
II2H3+
II2H3B/P
EXCLUSIVE
30 MIX C.S.I.
II2H3+
II2H3B/P
EXCLUSIVE
35 MIX C.S.I.
II2H3+
II2H3B/P
EXCLUSIVE
30 MIX R.S.I.**
II2H3+
II2H3B/P
EXCLUSIVE
35 MIX R.S.I.**
II2H3+
II2H3B/P
1007_0 EN 12/14
Beretta International Markets
Trading address: Via Risorgimento 23/A - 23900 LECCO - ITALY Tel. +39-0341-277111 - fax +39-0341-277263 info@berettaboilers.com www.berettaboilers.com
In order to improve its product, Beretta reserves the right to modify the characteristics and information shown in this manual at any time and without advance warning. This brochure, therefore, cannot be considered as contractually binding on third parties.