Manual P/N 5900282 — Manual Revision A — February 2023
• HD-75BXT
HD-75BXT shown above.
Designed and engineered by BendPak Inc. in Southern California, USA. Made in China.
IMPORTANT Safety Instructions, save these
DANGER
instructions! Read the
before
safety precautions in this manual can result in serious injury or
death. Make sure all other operators also read this manual. Keep
the manual near the product for future reference.
with installation and operation, you agree that you fully
understand the contents of this manual and assume full
responsibility for product use
using this product. Failure to follow the instructions and
Trademarks. BendPak and the BendPak logo are registered trademarks of BendPak Inc. All other company,
product, and service names are used for identification only. All trademarks and registered trademarks mentioned
in this manual are the property of their respective owners.
Limitations. Every effort has been made to make sure complete and accurate instructions are included in this
manual. However, product updates, revisions, and/or changes may have occurred since this manual was
published. BendPak reserves the right to change any information in this manual without incurring any obligation for
equipment previously or subsequently sold. BendPak is not responsible for typographical errors in this manual.
You can always find the latest version of the manual for your product on the BendPak website.
Warranty. The BendPak warranty is more than a commitment to you: it is also a commitment to the value of
your new product. Contact your nearest BendPak dealer or visit www.bendpak.com/support/warranty for
full warranty details. Go to bendpak.com/support/register-your-product/ and fill out the online form to
register your product (be sure to click Submit).
Safety. Your product was designed and manufactured with safety in mind. However, your safety also depends
on proper training and thoughtful operation. Do not install, operate, maintain, or repair the unit without reading and
understanding this manual and the labels on the unit;
do not use your Lift unless you can do so safely!
Owner Responsibility. To ensure operator safety and maintain your product properly, it is the responsibility of
the product owner to read and follow these instructions:
• Follow all setup, operation, and maintenance instructions.
• Make sure product setup and use conforms to all applicable local, state, and federal codes, rules, and
regulations, such as state and federal OSHA regulations and electrical codes.
• Read and follow all safety instructions. Keep them readily available for operators.
• Make sure all operators are properly trained, know how to safely operate the unit, and are properly supervised.
• Do not operate the product until you are certain all parts are in place and operating correctly.
• Carefully inspect the product on a regular basis and perform all maintenance as specified.
• Service and maintain the unit only with approved replacement parts.
• Keep all instructions permanently with the product and make sure all labels are clean and visible. BendPak
makes no promises, guarantees or assurances that our products meet any state, county, federal or
international mandated permit, license, code, standard, certification, or any other mandate other than what is
listed or shown on BendPak website(s), or any BendPak or Ranger online or published catalog. Not all
BendPak lift models meet the standards as prescribed by ANSI/ALI ALCTV-(current edition) or ANSI/UL 201.
Consult www.autolift.org for a complete list of lift models that meet ANSI/ALI ALCTV-(current edition) or
ANSI/UL 201, or contact BendPak via contact@bendpak.com. Buyer assumes full responsibility for any
state, county, federal or international mandated permit, license, code, standard, certification, or any other
mandate required related to the installation and/or operation of any BendPak or Ranger product. BENDPAK
will not be responsible for any charges, fines, liens, or other levies imposed on the Buyer related to any special
or regional structural, seismic or any other building code and/or codes such as the Uniform Building Code
(UBC), International Building Code (IBC), or any other state, county, federal or international mandated permit,
license, code, standard, certification, or other mandate, law, rule, regulation or directive by any other agency,
government, administrations, or corporations whether state, county, federal, or international mandated.
•Only use the Lift if it can be used safely!
Page 3
Unit Information. Enter the Model Number, Serial
Number, and the Date of Manufacture from the label
on your unit. This information is required for part or
warranty issues.
Model:
Serial:
Date of Manufacture:
HD-75BXT Series Four-Post Lifts 3P/N 5900282 — Rev. A — February 2023
Page 4
Table of Contents
Introduction 4 Operation 64
Shipping Information 4 Maintenance 68
Safety Considerations 5 Troubleshooting 70
Components 8 Wiring Diagrams 72
Specifications 10Labels 73
FAQs 12Parts Drawings 76
Installation Checklist 13 Maintenance Log 83
Installation 14
Introduction
This manual describes the following BendPak Four-Post Lifts:
• HD-75BXT: Four-Post Lift with an overall width of 132 inches (11 feet). The Lift is capable of
raising Vehicles and Boats up to 7,500 pounds (3,402 kg).
This manual is mandatory reading for all users of the HD-75BXT, including anyone who installs, uses,
maintains, repairs, or wants to know more about them.
⚠ DANGER Use care when installing, operating, maintaining, or repairing this equipment; failure
Keep this manual on or near the equipment so that anyone who uses or services it can read it.
If you are having issues, refer to the Troubleshooting section of this manual for assistance.
Technical support and service is available from your dealer, on the Web at bendpak.com/support,
by email at support@bendpak.com, or by phone at (800) 253-2363, extension 196.
You may also contact BendPak for parts replacement information at (800) 253-2363, extension
191; please have the model and serial number of your unit available.
to do so could result in property damage, product damage, injury, or (in very rare
cases) death. Make sure only authorized personnel operate this equipment. All
repairs must be performed by an authorized technician. Do not make modifications
to the unit; this voids the warranty and increases the chances of injury or property
damage. Make sure to read and follow the instructions in this manual and on the
labels on the unit.
Shipping Information
Your equipment was carefully checked before shipping. Nevertheless, you should thoroughly inspect
the shipment
HD-75BXT Series Four-Post Lifts 4P/N 5900282 — Rev. A — February 2023
before
you sign to acknowledge that you received it.
Page 5
When you sign a bill of lading, it tells the carrier that the items on the invoice were received in good
condition.
the items listed on the bill of lading are missing or are damaged, do not accept the shipment until the
carrier makes a notation on the bill of lading that lists the missing and/or damaged goods.
To protect yourself, do not sign until after you have inspected the shipment.
If any of
If you discover missing or damaged goods
lading, notify the carrier at once and request the carrier to make an inspection. If the carrier will not
make an inspection, prepare a signed statement to the effect that you have notified the carrier (on a
specific date) and that the carrier has failed to comply with your request.
It is difficult to collect for loss or damage after you have given the carrier a signed bill of lading. If this
happens to you, file a claim with the carrier promptly. Support your claim with copies of the bill of
lading, freight bill, invoice, and photographs, if available. Our willingness to assist in helping you
process your claim does not make us responsible for collection of claims or replacement of lost or
damaged materials.
Safety Considerations
Read this entire manual carefully before using your new product.
operate the product until you are familiar with all operating instructions and warnings. Refer to
ANSI/ALI ALIS Standard Safety Requirements for Installation and Service of Automotive Lifts for more
information about safely installing your Lift.
⚠ WARNINGCalifornia Proposition 65. This product can expose you to chemicals including
styrene and vinyl chloride which are on the list of over 900 chemicals identified by
the State of California to cause cancer, birth defects or reproductive harm.
ALWAYS use this product in accordance with BendPak BendPak’s instructions.
For more information go to www.P65Warnings.ca.gov.
after
you receive the shipment and have signed the bill of
Do not install or
Important Safety Instructions!
Save these instructions!
1. Read all instructions.
2. Care must be taken as burns can occur from touching hot parts.
3. Do not operate equipment with a damaged cord or if the equipment has been dropped or
damaged – until it has been examined by a qualified service person.
4. Do not let a cord hang over the edge of a table, bench, or counter or come in contact with hot
manifolds or moving fan blades.
5. If an extension cord is necessary, a cord with a current rating equal to or more than that of the
equipment should be used. Cords with a current rating less than the equipment may overheat.
Care should be taken to arrange the cord so that it will not be tripped over or pulled.
6. Always unplug the equipment from the electrical outlet when not in use. Never use the cord to pull
the plug from the outlet. Grasp the plug and pull to disconnect.
7. Let the equipment cool completely before putting away. Loop cord loosely around equipment
when storing.
8. To reduce the risk of fire, do not operate in the vicinity of open containers of flammable liquids
(gasoline).
HD-75BXT Series Four-Post Lifts 5P/N 5900282 — Rev. A — February 2023
Page 6
9. Adequate ventilation should be provided when working on operating internal combustion engines.
10. Keep hair, loose clothing, fingers, and all parts of body away from moving parts.
11. To reduce the risk of electric shock, do not use on wet surfaces or expose to rain.
12. Use only as described in this manual. Use only BendPak recommended attachments.
13. ALWAYS WEAR SAFETY GLASSES. Everyday eyeglasses only have impact resistant lenses, they
are not safety glasses.
14. To reduce the risk of injury, close supervision is necessary when this product will be used around
children.
15. To reduce the risk of injury,
instructions.
16. The Lift uses electrical energy; if your organization has Lockout/Tagout policies, make sure to
implement them after connecting the Lift to a power source.
17. Refer to markings for proper load on electrical receptacles.
18. Only operate your Lift between temperatures of +41°F to +104°F (+5°C to +40°C).
19. The Lift should
away from the Lift.
20. Do not make any modifications to the Lift; this voids the warranty and increases the chances of
injury or property damage.
21. Do not use the Lift while tired or under the influence of drugs, alcohol, or medication.
22. Consider the work environment. Keep the work area clean. Cluttered work areas invite injuries.
Keep areas well lit.
23. Always make sure the Lift is secured on Safety Locks before attempting to work on or near a
Vehicle.
24. Make a thorough inspection of the product at least once a year. Replace any damaged or severely
worn parts, decals, or warning labels. Replace worn or damaged parts with BendPak or BendPak
approved parts and assemblies only.
only
be operated by authorized personnel. Keep children and untrained personnel
never
attempt to lift more than the rated capacity. Refer to loading
25. BendPak recommends referring to the ANSI/ALI ALIS Standard Safety Requirements for Installation and Service for more information about safely installing, using, and servicing your Lift.
26. The HD-75BXT Lift is Parking Lift.
27. You
28. Keep loads balanced on the Lift Arms. Clear the area immediately if a Vehicle is in danger of falling
29. Modifications void the warranty and increases the chances of injury or property damage. Do not
30. Make sure all operators read and understand this Installation and Operation Manual. Keep the
31. While handling a Hydraulic Cylinder or a Hydraulic Hose,
HD-75BXT Series Four-Post Lifts 6P/N 5900282 — Rev. A — February 2023
must
when installing, using, maintaining, or repairing the Lift. Leather gloves, steel-toed work boots, eye
protection, back belts, and hearing protection are
off the Lift. Do not make any modifications to the Lift.
modify any safety-related features in any way.
manual near the Lift at all times.
needle-like stream of hydraulic fluid (even at low pressure) can penetrate fingers, hands, or arms;
such a puncture can feel like a bite, electric shock, or a prick. While it may seem like a minor
issue, any amount of Hydraulic Fluid injected into the human body is a serious issue. Anyone
wear OSHA-approved (publication 3151) personal protective equipment at all times
Use it only for its intended purpose.
mandatory
.
always
wear gloves. In rare cases, a
Page 7
suffering such a puncture wound should be
to determine the extent of the injury. Explain the circumstances of the injury to the attending
physician, including what kind of Hydraulic Fluid was involved. Do not assume a puncture wound
that could have been caused by Hydraulic Fluid is a minor issue; it could be life threatening.
immediately
taken to a hospital emergency room
32. Make an inspection of the Lift
not use it if you find any of these issues. Instead, take it out of service, then contact an authorized
repair facility, your dealer, or BendPak at (877) 432-6627 or support@BendPak.com.
33. To reduce the risk of property damage, personal injury, or loss of life,
the Lift’s runways without placing suitable Wheel Chocks behind each rear tire so that the vehicle
cannot roll backwards off the Lift. Vehicles parked on the Lift
First Gear (Manual Transmission) with the Parking Brake fully applied.
before
using it. Check for damaged, worn, or missing parts. Do
MUST
NEVER
also be placed in Park or
park any vehicle on
Symbols
Following are the symbols used in this manual:
⚠ DANGERCalls attention to an immediate hazard that will result in injury or death.
⚠ WARNINGCalls attention to a hazard or unsafe practice that could result in injury or death.
⚠ CAUTIONCalls attention to a hazard or unsafe practice that could result in minor personal
injury, product, or property damage.
NOTICE Calls attention to a situation that, if not avoided, could result in product or property
damage.
TipCalls attention to information that can help you use your product better.
Liability Information
BendPak Inc. assumes no liability for damages resulting from:
• Use of the product for purposes other than those described in this manual.
• Modifications to the equipment without prior, written permission from BendPak Inc.
• Injury or death caused by modifying, disabling, overriding, or removing safety features.
• Damage to the equipment from external influences.
• Incorrect operation of the equipment.
HD-75BXT Series Four-Post Lifts 7P/N 5900282 — Rev. A — February 2023
Page 8
Components
The main components of your Lift include:
• Power Post. The Post that holds the Power Unit.
locations
Brackets on it. Mount the Power Unit on one of the two Mounting Brackets.
• The other three Posts. These Posts are functionally interchangeable; their Labels are different.
• Power Unit. An electric/hydraulic unit that connects to an electric power source and then
provides hydraulic power to the Hydraulic Cylinder that raises and lowers the Runways.
• Lifting Cables. The two Runways are lifted by .4 inch / 10 mm thick aircraft-quality steel wire
rope, each of which is rated at 14,400 pounds.
• Boat Trailer Tongue Platform (TC-3000 model). Mounts between the Runways and supports
the front jack of your boat trailer.
• Power Side Runway. The Runway next to the Power Post. The Power Side Runway has Lifting
Cables and the Hydraulic Cylinder on its underside. You
the Power Post.
• Offside Runway. The other Runway. It does not have a Hydraulic Cylinder or Lifting Cables
under it.
• Utility Rails. Hold the optional Rolling Jacks. Utility Rails
• Crosstubes. One at each end of the Lift. The Crosstubes are hollow; the Lifting Cables that raise
and lower the Runways are routed through the Crosstubes. The Crosstubes are not the same:
each Crosstube has an opening (called a Window) that faces the inside (orienting the Windows
correctly is described in the Installation section).
. You can tell the Power Post from the other Posts because it has two Mounting
open to the inside of the Lift
• Ramps. One for each Runway. Use them to drive onto and off of the Runways. By definition, the
Ramp end of the Lift is also the Rear of the Lift.
• Tire Stops. Located at the Front of the Lift, Tire Stops prevent the Vehicle’s front tires from going
any farther forward. Additionally, we strongly recommend chocking the Vehicle’s rear tires.
• Safety Locks. Once engaged, they hold the Runways in position, even if the power goes out or
there is a leak in the Hydraulic Hoses.
a Safety Lock.
• Pushbutton Air Valve. Includes a Pushbutton that moves the Safety Locks away from the
Ladder so that they do not engage as you lower the Runways. Used only to lower the Runways.
• Ladder. A piece of steel that gets installed at the back of each Post.
The Power Post can be in either of two
must
put the Power Side Runway next to
must
go on the inside of the Lift.
Windows must be installed so that they
. Lifting Cables go into the Crosstubes through the Windows.
Only leave your Lift on the ground or engaged on
HD-75BXT Series Four-Post Lifts 8P/N 5900282 — Rev. A — February 2023
Page 9
Drawing not to scale. Components removed for clarity.
HD-75BXT Series Four-Post Lifts 9P/N 5900282 — Rev. A — February 2023
Page 10
Specifications
HD-75BXT Series Four-Post Lifts 10P/N 5900282 — Rev. A — February 2023
Page 11
Model HD-75BXT
Lifting capacity
Maximum capacity front axle
Maximum capacity rear axle
a Min. Runway Height, Lowered
b Maximum Rise
c Maximum Lifting Height
d Overall Width
2
e Outside Length
f Overall Length
g Height of Post
h Distance Between Posts
i Drive-Through Clearance, Width
j Runway Width
k Runway length
7,500 lbs. / 3,402 kg
3,750 lbs. / 1,701 kg
3,750 lbs. / 1,701 kg
5 in. / 125 mm
82 in. / 2,058 mm
87 in. / 2,208 mm
132.2 (±.125) in. / 3,357 (±3.2) mm see footnote 2
222 in. / 5,638 mm
248.5 in. / 6,313 mm
100 in. / 2,537 mm
122.25 in. / 3,103 mm
108.5 in. / 2,756 mm
19 in. / 482 mm
212.5 in. / 5,398 mm
l Width Between Runways
m Runway Centerline
n Outside Edge of Runways
68.5 in. (narrow) or 88.5 in. (wide) / 1,740 mm or 2,248 mm
87.5 in. (narrow) or 107.5 in. (wide) / 2,223 mm or 2,731 mm
o Drive-Thru Clearance, Height
Min. Wheelbase @ rated capacity 1
Min. Wheelbase @ 75% capacity 1
Min. Wheelbase @ 50% capacity 1
Min. Wheelbase @ 25% capacity 1
Locking Positions
Lifting time
Motor
Air supply 3 to 25 cfm at 50 to 150 psi
1
The Lift supports less weight than its rated capacity when the Vehicle’s wheelbase is shorter; this is due to
the wheels moving closer to the middle of the Runways, where there is less support. For example, the
maximum weight allowed on the Lift for a Vehicle with a wheelbase of 110 inches is 50 percent of the Lift’s
rated capacity or 3,750 lbs.
2
The Safety Ladder fasteners extend past the Post by .75 in. / 19 mm on all four Posts making the Overall
Width with fasteners 133.5 in. / 3,390 mm. This larger dimension is for refence only and should not be
used to create the Chalk Lines.
46.5 in. – 66.5 in. / 1,181 mm – 1,689 mm
80.9 in. / 2055 mm
150 in. / 3,810 mm
130 in. / 3,302 mm
110 in. / 2,794 mm
90 in. / 2,286 mm
17 spaced every 4 in. / 102 mm
≈50 seconds
208-230 VAC, 60 Hz, 1 Ph
Specifications subject to change without notice.
HD-75BXT Series Four-Post Lifts 11P/N 5900282 — Rev. A — February 2023
Page 12
Frequently Asked Questions
Question: What kinds of Vehicles can I put on my Lift?
Answer: Cars, trucks, SUVs; anything that fits on the Runways, up to 7,500 lbs. (3,402 kg) and
Boats too using the TC-3000 Trailer Tongue Assembly.
Q: How long does it take to raise or lower my Lift with a Vehicle on it?
A: About 45 to 55 seconds. Lowering times are longer if there is no weight on the Lift.
Q: Does the Lift have a Front and a Rear?
A: Yes. For a Four-Post Lift, the end
the Rear.
Q: Do I have to put my Power Unit in a particular location?
A: Yes. Your Power Post (the Post the holds the Power Unit) must be located at either the
Driver-Side Front or the Passenger-Side Rear of the Lift. More on this later.
Q: Does the Lift have to be anchored in place?
A: Yes. BendPak strongly recommends that you anchor the Lift; it may be less stable if you do not
anchor the Bases.
opposite
the Ramps is the Front; the end with the Ramps is
Q: How high does the ceiling have to be?
A: It depends on the height of the Vehicle you are putting on the Runways and how high you raise
the Runways. If you are going to put a tall Vehicle or Boat on the Lift and raise it all the way up,
you should check to make sure there is enough room.
Q: Does it matter if I drive my Vehicles in front first or back them in?
A: We recommend driving your Vehicle in front first, because that makes it easier to center the
wheels on the Runways. But it is up to you; the Lift works great either way.
vehicle on the Lift’s runways without placing two suitable wheel chocks behind each rear tire so
that the vehicle cannot roll backward off the Lift.
Q: Will the Lifting Cables really hold my Vehicle?
A: Yes. Each Lifting Cable is 0.4 inches thick, aircraft-quality steel
Q: Do I need an Air Supply?
A: Yes. An Air Supply (3 to 25 cfm at 50 to 150 psi) is required to disengage the Safety Locks when
you want to lower the Lift. Regulate the line to a maximum pressure of 150 psi; the Air Lines could
burst or the Safety Locks malfunction at pressures over 150 psi.
Q: How long can I leave a Vehicle on a raised Runway?
A: As long as you want. Once the Lift is engaged on a Safety Lock, gravity holds it in position, so a
loss of power or a leaking Hydraulic Hose will not affect the Lift.
fully lowered or engaged on Safety Locks
.
wire rope
Only leave your Lift either
NEVER
.
park any
Q: Can I install my Lift outside?
A: No. Your Lift is approved for indoor installation and use only.
prohibited
HD-75BXT Series Four-Post Lifts 12P/N 5900282 — Rev. A — February 2023
.
Outdoor installation is
Page 13
Installation Checklist
Following are the steps needed to install your Lift. Perform them in the order shown.
☐ 1. Review the Safety Rules.
☐ 2. Make sure you have the necessary Tools.
☐ 3. Plan for electrical work.
☐ 4. Choose a Power Post Location.
☐ 5. Check the Clearances above the Vehicle.
☐ 6. Check the Clearances around the Lift.
☐ 7. Select the Installation Location.
☐ 8. Unload and unpack the Lift Components.
☐ 9. Create Chalk Line Guides.
☐ 10. Move the Posts into position.
☐ 11. Install the Crosstubes.
☐ 12. About Safety Locks.
☐ 13. Install the Ladders and Top Caps.
☐ 14. Raise the Crosstubes.
☐ 15. Secure the Ladders.
☐ 16. Remove the Sheaves.
☐ 17. Install the Runways.
☐ 18. Install the first end of the Flex Tube.
☐ 19. Extend the Piston and Route the Lifting Cables.
☐ 20. Install the Power Unit.
☐ 21. About Hydraulic Fluid Contamination.
☐ 22. About Thread Sealants.
☐ 23. Filling the Hydraulic Fluid Reservoir.
☐ 24. Install the second end of the Flex Tube.
☐ 25. Working with Compression Fittings and Tubing.
☐ 26. Install the Pushbutton Air Valve and connect the Air Line.
☐ 27. Connect the Return Line.
☐ 28. Connect the Hydraulic Hose.
☐ 29. Contact the Electrician.
☐ 30. Connect to a power source (
☐ 31. Install the Power Disconnect Switch and Thermal Disconnect Switch (
☐ 32. About Effective Embedment.
☐ 33. Anchor the Posts.
☐ 34. Perform final leveling.
☐ 35. Install the Accessories.
☐ 36. Lubricate the Lift.
☐ 37. Perform an Operational Test.
☐ 38. Review the Final Checklist.
Electrician required
).
Electrician required
).
HD-75BXT Series Four-Post Lifts 13P/N 5900282 — Rev. A — February 2023
Page 14
Medium crescent wrench, torque wrench,
Installation
The installation process requires multiple steps. Perform them in the order listed.
Read the entire Installation section before beginning the installation
better understanding of the assembly process.
⚠ WARNING
Only use the factory-supplied parts that came with your Lift
parts from a different source, you void your warranty and compromise the safety of
everyone who installs or uses the Lift. If you are missing parts, visit
bendpak.com/support or call (800) 253-2363, extension 191.
; this will provide a
. If you use
Being Safe
While installing this equipment, your safety depends on proper training and thoughtful operation.
⚠ WARNING Do not install this equipment unless you have Automotive Lift installation training.
Always use proper lifting tools, such as a Forklift or Shop Crane, to move heavy
components. Do not install this equipment without reading and understanding this
manual and the safety labels on the unit.
Only fully trained personnel should be involved in installing this equipment. Pay attention at all times.
Use appropriate tools and lifting equipment. Stay clear of moving parts.
BendPak recommends referring to the current version of the ANSI/ALI ALIS Standard Safety Requirements for Installation and Service for more information about safely installing, using, and
servicing your Lift.
⚠ WARNING You must wear appropriate protective equipment
gloves, steel-toed work boots, eye protection, back belts, and hearing protection.
Tools
You may need some or all of the following tools and supplies:
• Rotary hammer drill (or similar)
• ¾ inch carbide bit (conforming to ANSI
B212.15)
• Hammer, crow bar, and two sawhorses
• Four-foot level and 12-foot ladder
• Open-end wrench set, SAE and metric
• Socket and ratchet set, SAE and metric
• Hex key wrench set
at all times
•
pipe wrench
• Chalk line
• Medium-sized flat screwdriver and needle-
nose pliers
• Tape measure (25 feet or above)
• Forklift, shop crane, or heavy-duty rolling dolly
• Red and White Lithium Grease
during installation:
HD-75BXT Series Four-Post Lifts 14P/N 5900282 — Rev. A — February 2023
Page 15
Planning for Electrical Work
A licensed Electrician will be required at some point during the installation.
⚠ DANGERAll electrical work
Notify your Electrician in advance so that they arrive prepared with appropriate components for
connecting to the facility power source, a Power Disconnect Switch, and a Thermal Disconnect
Switch. Refer to Contacting the Electrician for more information. Your Electrician needs to:
• Connect the Power Unit to an electrical power source. An electric power source is
required. The Power Unit comes with a Pigtail for wiring to a power source. Have your Electrician
connect a power cord with appropriate plug to the electrical box on the Lift (for connection to a
power outlet) or have them wire it directly into the electrical system at the Lift location protected by
an appropriate circuit breaker.
Note that installing the Power Unit and connecting the Power Unit to the power source are
separate procedures and are done at different times in the installation process. You do
an Electrician to install the Power Unit, but an Electrician is
the power source.
• Install a Power Disconnect Switch. This switch ensures you can quickly and completely
interrupt electrical power to the Lift in the event of an electrical circuit fault, emergency, or when
equipment is undergoing service or maintenance. Install the disconnect within sight and reach of
the Lift operator.
• Install a Thermal Disconnect Switch. The thermal disconnect ensures the equipment shuts
down in the event of an overload or an overheated motor.
Note: These components are not supplied with the Lift.
must
be performed by a licensed Electrician.
required
not
need
to connect the Power Unit to
Selecting a Power Post Location
Choose a Power Post location now, as its location impacts other aspects of the installation.
You have two options for Power Post location: Driver-Side Front or Passenger-Side Rear.
HD-75BXT Series Four-Post Lifts 15P/N 5900282 — Rev. A — February 2023
Page 16
12 in. / 308 mm Min
.
Distance to nea
rest
obstruc�o n
Note: The Power Post location decision has no impact on the Approach direction.
Power Side Runway (which has the Hydraulic Cylinder under it)
Post, no matter which Power Post location you choose.
Most customers choose their Power Post location based on either preference (one option makes more
sense for their shop than the other does) or easier access to the power source.
must
be installed next to the Power
Checking Clearances
For safety purposes, a certain amount of clear space around and above the Lift is
Check Clearance Above the Vehicle
A minimum of 12-inches above the highest point on the vehicle is required to allow room to lift off of
the safety locks.
required
.
Side view. Not to scale. Components removed for clarity.
HD-75BXT Series Four-Post Lifts 16P/N 5900282 — Rev. A — February 2023
Page 17
Check Clearances Around the Lift
Drawing is a top view. Not to scale. Not all components shown.
HD-75BXT Series Four-Post Lifts 17P/N 5900282 — Rev. A — February 2023
Page 18
Selecting a Location
When selecting the location for your Lift, consider:
• Architectural plans. Consult the architectural plans for your desired installation location. Make
sure there are no issues between what you want to do and what the plans show.
• Available space. Make sure there is enough space for the Lift: front, back, sides, and
Refer to Specifications for measurements.
• Overhead obstructions. Check for overhead obstructions such as building supports, heaters,
electrical lines, low ceilings, hanging lights, and so on.
Lift hitting obstructions
• Side and front clearances. You must leave room around the Lift. Leave at least six feet (72
inches / 1.8 meters) clear on both sides and the front of the Lift, and no obstructions at all at the
Rear of the Lift (so you can safely drive Vehicles onto the Runways).
• Power. You need an appropriate power source for the Power Unit.
• Outdoor installations. Your Lift is approved for indoor installation and use
• Floor. Only install the Lift on a flat, Concrete floor; do not install on asphalt or any other surface.
The surface must be level; do not install if the surface has more than three degrees of slope.
.
You do not want the Vehicles on the
only
above
.
.
⚠ WARNING Installing your Lift on a surface with more than three degrees of slope could lead to
injury or even death. Only install the Lift on a level floor. If your floor is not level,
consider making the floor level or using a different location.
• Shimming. If your Concrete floor is not completely level, you can use Shims under the bases of
the Posts, to a maximum of 0.5 in. / 13 mm, to level the Lift.
To estimate your Shim requirements, use a transit level and targets to check for flatness. Use the
provided Shims as necessary.
NOTICE Do not shim a Post more than half an inch using the provided Shims and Anchor Bolts.
A maximum shim of 2 inches is possible by ordering optional Shim Plates. Contact
BendPak at (800) 253-2363, extension 191 to order.
• Concrete specifications. Do not install the Lift on cracked or defective Concrete. Verify the
Concrete is at least 4.25 inches thick, 3,000 PSI, and cured for a minimum of 28 days. Do not
install Anchor Bolts within six inches of cracks, expansion joints, or other defects in the Concrete.
⚠ CAUTION BendPak lifts are supplied with installation instructions and Concrete anchors that
meet the criteria set by the current version of the American National Standard
“Automotive Lifts – Safety Requirements for Construction, Testing, and Validation”,
ANSI/ALI ALCTV. You are responsible for any special regional structural and/or
seismic anchoring requirements specified by any other agencies and/or codes such
as the Uniform Building Code (UBC) and/or International Building Code (IBC).
Be sure to check your Concrete floor for the possibility of it being a
case, you must contact the building architect before drilling. Using ground penetrating radar may
help you find the tensioned steel.
post-tension slab
. In this
⚠ WARNING Cutting through a tensioned cable can result in injury or death. Do not drill into a
post-tension slab unless the building architect confirms you are not going to hit
tensioned steel or you have located it using ground penetrating radar.
sheath comes up during drilling, stop drilling immediately
HD-75BXT Series Four-Post Lifts 18P/N 5900282 — Rev. A — February 2023
If colored
.
Page 19
Unloading and Unpacking
Try to have the components of the Lift unloaded near the installation location.
Once the components are unloaded, they are your responsibility to move around. As the Lift includes a
number of heavy pieces, the closer you unload them to the installation location, the better off you are.
⚠ CAUTIONSome Lift components are very heavy; if handled incorrectly, they can damage
materials like tile, sandstone, and brick. Try to handle the Lift components twice:
once when delivered and once when moved into position. You must have a Forklift
or Shop Crane to move them into position. Use care when moving them.
⚠ WARNING The Posts and Runways are delivered with stabilizing structures on each end. Be
very careful when removing these stabilizing structures; the Posts and Runways
can shift or even fall. If they fall on a person, they could cause serious injury.
HD-75BXT Series Four-Post Lifts 19P/N 5900282 — Rev. A — February 2023
Page 20
Creating Chalk Line Guides
Create Chalk Line Guides so that the outside edges of all four Post bases fit into the four corners
created by the Chalk Line Guides.
Refer to Specifications to determine the Overall Width and
Note: Do
Note: Pay careful attention to the Overall Width measurement. It is critical to keep this
not
use the
consideration for creating Chalk Line Guides.
measurement within ±.125 in. / 3.2 mm.
Overall
Length value; this includes the Ramps, which are not taken into
Outside
Length values for your Lift.
Drawing is a top view. Not to scale. Not all components shown.
To create Chalk Line Guides:
1. Create the Front Chalk Line where you want the Front of the Lift.
Make the Front Chalk Line longer, by 12 inches on each end, than the Overall Width setting.
2. Create the two side Chalk Lines at a 90° angle to the Front Chalk Line and parallel to each other.
Make the side Chalk Lines longer (by 12 inches on each end) than the Outside Length setting.
All Chalk Lines
Measure to verify that they are parallel.
3. Create the Rear Chalk Line parallel to the Front Chalk Line. Make the Rear Chalk Line longer than
the Overall Width setting for your Lift model.
HD-75BXT Series Four-Post Lifts 20P/N 5900282 — Rev. A — February 2023
must
be parallel and perpendicular to each other.
Page 21
The Front and Rear Chalk Lines
Measure to verify that they are parallel.
must
also be parallel to each other.
4. Before moving the Posts into position, measure
measurements are the same.
5. When you move the Posts into position, put the outside edges of the bases inside the corners
created by the Chalk Line Guides.
Do not forget to check the diagonals.
diagonally
to verify the two diagonal
Moving the Posts into Position
Use a Forklift or Shop Crane to move the Posts. Have
up the Posts.
at least two people
work together to stand
⚠ DANGERThe Posts are heavy and awkward; be very careful when handling them. If they fall
on a person, they will cause injury.
To move the Posts into position:
1. Using a Forklift or Shop Crane, move the four Posts, one at a time, to the inside corners of the
Chalk Line Guides.
Important: Position the Power Post at the location you chose earlier. The other three Posts can go
at any of the remaining Post locations.
2. Stand up each Post.
Have
at least two people
work together to stand up a Post.
⚠ WARNING Be very careful when walking around the Posts; they are not anchored down at this
point, so it is possible to knock them over, which could cause significant injury.
3.
Do not anchor the Posts at this point
HD-75BXT Series Four-Post Lifts 21P/N 5900282 — Rev. A — February 2023
.
Page 22
Installing the Crosstubes
Your Lift has two Crosstubes;
• One Crosstube has Two
end of the Power Side Runway.
• One Crosstube has Two
Both Crosstubes are hollow, which allows the Lifting Cables to run through them to the Posts.
TipIt is possible to install the Crosstubes incorrectly in several different ways. Take your
time and get it right the first time.
Both Crosstubes
Important: Your Power Post location impacts Crosstube installation. The Crosstube with two Small
Crosstubes
The following drawing shows the two Crosstube setups based on Power Post location.
must
be installed so that the Windows open to the inside of the Lift.
Windows
come into play when determining where the Crosstubes get installed.
must
be installed so that their Windows are on the Power Side Runway side of the Lift.
they are similar, but not the same
Large
Small
must
be installed next to the Power Post. The location of the Ramps do not
Windows and must be installed at the Cable Retainer Block
Windows and must be installed adjacent to the Power Post.
:
Top view. Drawing not to scale. Components removed for clarity. The location of the Ramps does not
change based on Power Post location, but the Power Side Runway and Crosstube locations do.
Windows are in the Crosstubes; they are shown here at the ends of the Power Side Runway for clarity.
HD-75BXT Series Four-Post Lifts 22P/N 5900282 — Rev. A — February 2023
Page 23
To install the Crosstubes:
1. Orient the Crosstubes in their
• The Crosstube with two Large Windows must be on the Cable Retainer Block end of the
Power Side Runway with both Windows facing the inside of the Lift.
• The Crosstube with two Small Windows must be located next to the Power Post with both
Windows facing the inside of the Lift.
Both Windows must be on the ends of the Power Side Runway and facing the inside of the Lift.
2. Lean over the
people let them lay on the ground), slide the Crosstube into place, then stand the Posts back up
again (make sure to put them back into their correct locations).
or
Using a Forklift or Shop Crane, raise a Crosstube above the top of the two Posts, then slide the
Crosstube down into place.
3. Perform Step 2 for the second Crosstube.
two
Posts at one end of the Lift (some people put them on Sawhorses, some
required
locations:
About Slide Blocks
The black Slide Blocks in the corners on the ends of the Crosstubes come installed from the factory. If
they fall off or do not come installed, put them into place so that each pair creates a Slot into which the
Ladder for each Post will be installed later in the installation procedure.
In the drawings below, the drawing on the left shows how two Slide Blocks get put into position; the
drawing on the right shows the Slot created by the two Slide Blocks when they are installed. There are
two Slots per Crosstube Gusset, one at the top and one at the bottom.
The Ladder
Important: It is easy to see the top Slot created by the Slide Blocks. It is difficult to see the bottom
must
go through
Slot, but it is
both
Slots.
required
that the Ladder go through
both
Slots.
HD-75BXT Series Four-Post Lifts 23P/N 5900282 — Rev. A — February 2023
Page 24
Safety Locks hold the Runways in place. Once engaged,
Safety Locks hold the Runways in place, even if the
power goes out or the Hydraulic Hoses break or leak.
Important
⚠
The Ladders are steel pieces with holes spaced every
four inches. As you raise the Runways, the Primary
Safety Locks move into the holes in the Ladder
you move the Runways back down after passing a
Safety Lock hole, the Safety Lock engages
are engaged, Safety Locks stay engaged until you lower
the Runways
⚠
About Safety Locks
: Simply raising the Runways does not
engage
Locks. You must back the Runways
down onto the Safety Locks to engage
them.
WARNING Safety Locks are dependent on
them on the Primary Safety
correct installation of the Ladders.
Pay careful attention when installing
the Ladders, thus ensuring correct
operation of the Safety Locks on your
Lift.
. When
.
WARNING Always leave the Runways either fully
lowered or engaged on the Primary
Safety Locks. When you engage the
Safety Locks at a desired height,
check to make sure that all four
Safety Locks are engaged at the
same height.
So how do the Runways come down if the Primary Safety Locks are engaged? To lower the Runways,
you raise them a few inches (to get them off the Primary Safety Locks), then
Pushbutton Air Valve. While you hold down the pushbutton, the Primary Safety Locks are moved away
from the Safety Lock holes in the Ladders; they are prevented from engaging, which allows the
Runways to be lowered.
Out of abundance of caution, your Lift has a second, independent Safety Lock system called the Slack
Safety. In total, your Lift has two Safety systems:
• Primary Safety Locks. Located at the ends of each of the four Crosstubes, the Primary Safety
Locks hold the Runways in place once they are engaged. Primary Safety Locks are used over 99
percent of the time. Once engaged, Primary Safety Locks hold the Runways in place, even if the
power goes out or the Hydraulic Hoses break or leak.
• Slack Safety Locks. Also located at the ends of each of the four Crosstubes, the Slack Safety
Locks are a backup system in case any of the four Lifting Cables break (which is a rare
occurrence). During normal operation, the Lifting Cables prevent the Slack Safety Locks from
engaging, but if a Lifting Cable breaks while the Lift is not engaged on its Primary Safety Locks, the
Slack Safety Lock next to the broken Lifting Cable immediately engages at the next Safety Lock
position in the Ladder.
. Once they
press and hold down
the
HD-75BXT Series Four-Post Lifts 24P/N 5900282 — Rev. A — February 2023
Page 25
Installing the Ladders and Top Cap
Your Lift has four Ladders (one per Post); each Ladder is installed on the inside back of a Post.
Ladders are secured at the top and the bottom of the Post. All four Ladders are identical.
It is
not
necessary to slide the Ladders in from the very top of the Post.
The Top Caps secure the Ladder at the top of each Post and hold the ends of the Lifting Cables.
Note: It is much easier to secure the bottom of the Ladders once the Crosstubes have been
raised, so that portion of installing the Ladders is described in Securing the Ladders.
Each Ladder has a Bolt Hole at the bottom and a Threaded Bolt at the top.
⚠ WARNINGMake sure to install the Ladders correctly. If they are not installed correctly, the
Safety Locks on your Lift may not hold the weight of a Vehicle, putting anyone
under and around the Lift in danger.
Not to scale. Components removed for clarity. Front and side views combined. Make sure to install
each Ladder through
HD-75BXT Series Four-Post Lifts 25P/N 5900282 — Rev. A — February 2023
both Slots
on each Crosstube Gusset.
Page 26
To install the Ladders and the Top Cap:
1. Take a Ladder and slide it down the back of a Post, with the Bolt Hole end at the bottom.
Make sure the Ladder goes through
Gusset and another Slot at the bottom of the Gusset; both are formed by the Slide Blocks.
Important: It is easy to see the top Slot created by the Slide Blocks. It is difficult to see the
bottom Slot, but it is
If the Ladder misses a Slot or the Slide Blocks were not installed correctly, your Safety Locks will
not
function correctly.
⚠ WARNINGMake sure all four Ladders go through
2. Install the other three Ladders the same way.
Moving to the top of the Ladders
3.
of the Ladder.
both
Slots on each Gusset. There is a Slot at the top of the
required
that the Ladder go through both Slots.
both
Slots created by the Slide Blocks.
, move the Stop Nut half of the way down towards the top
4. Put a Top Cap onto the top of the Post: put the Threaded Bolt on the top of the Ladder through
the appropriate hole, put the tabs on the side of the Top Cap inside the Post, and secure the Top
Cap on both sides with one Hex Head Bolt and one Nyloc Nut per side.
5. Once the Top Cap is secure, move the Stop Nut up until it contacts the underside of the Top
Cap, then add a Flat Washer and Nyloc Nut to the top of the Top Cap and tighten. Hand tighten
only.
About an inch of thread should extend above the top of the Top Nut.
Note: The other hole in the middle of the Top Cap is for the Lifting Cable, installed later.
6. Install the other three Top Caps the same way.
HD-75BXT Series Four-Post Lifts 26P/N 5900282 — Rev. A — February 2023
Page 27
Raising the Crosstubes
Manually raise the Crosstubes, to make it easier to complete the rest of the installation tasks. Both
Crosstubes are to be raised the same amount.
To raise the Crosstubes:
1. Using a Forklift or Shop Crane,
Raise the Crosstubes at least two feet off the ground, to have enough room to work under them
when routing the Lifting Cables, Return Line, Air Lines, and Hydraulic Hose.
Important: The Slack Safety Locks will automatically engage when you raise the Crosstubes. They
cannot
2. To disengage the Slack Safety Locks after raising a Crosstube: raise and hold one end of a
Crosstube until the Primary and Slack Safety Locks are disengaged, push and hold the Slack
Safety Roller in toward the Safety Ladder (this moves the Slack Safety Lock so it cannot engage),
lower the end of the Crosstube, then release the Slack Safety Roller.
be engaged as you continue with the installation, so they must be disengaged.
carefully
raise each Crosstube.
Figure not to scale. Components removed for clarity.
HD-75BXT Series Four-Post Lifts 27P/N 5900282 — Rev. A — February 2023
Page 28
The Primary Safety Lock is now engaged, but the Slack Safety Lock is not.
3. Disengage the other three Slack Safety Locks as done in Step 2.
4. Once both Crosstubes are raised,
Slack Safety Locks have been disengaged, you can continue with the installation.
all four Primary Safety Locks are engaged
, and all four
Securing the Ladders
Because it is much easier to secure the Ladders at the bottom of each Post
have been raised, that procedure is described here.
Note: The following procedure assumes that the Ladders are in place and secured at the top. If this
not
the case, return to Installing the Ladders and Top Cap.
is
To secure the Ladders:
1. Locate a Bolt, Washer, Spacer, second Washer, and Nut for each Ladder.
after
the Crosstubes
Side View. Not drawn to scale. Not all components are shown.
2. Put a Washer next to the Bolt head, then insert the Bolt just through the elongated hole near the
bottom of the Ladder.
3. Put the Spacer into position between the Ladder and the back of the Post.
4. Push the Bolt through the Spacer and then through the back of the Post.
5. Take the second Washer and the Nut and install them on the end of the Bolt; secure the Nut.
6. Perform the same procedure to secure the other three Ladders on the Lift.
Note: Do not securely tighten the Top Nut at the top of the Top Cap at this point. The Top Nut
and the Stop Nut will be used later to level the Lift. They can be securely tightened after
you do the final leveling of the Lift; refer to Final Leveling for additional information.
⚠ WARNINGMake sure all four Ladders are correctly installed and secured. If not, the Lift may
not be able to hold a Vehicle, which is a danger to anyone under the Vehicle or
around it.
7. Verify the Primary Safety Locks are engaged.
HD-75BXT Series Four-Post Lifts 28P/N 5900282 — Rev. A — February 2023
Page 29
⚠ WARNINGDo not continue with the installation until you have visually confirmed that all four
Primary Safety Locks are engaged. If they are not engaged, the Runways could
move or fall, possibly causing personal injury (even death) or product damage.
Removing Sheaves
To route the Lifting Cables, you first need to remove the Cable Sheaves on the underside of the Power
Side Runway, the two Side Sheaves, and the four Gusset Sheaves and their Lock Pins.
ImportantWhen you remove the Sheaves,
be reinstalling them at the same location, using the same components.
keep all of the components together
. You will
Not to scale. Components removed for clarity. Combines top and side views.
HD-75BXT Series Four-Post Lifts 29P/N 5900282 — Rev. A — February 2023
Page 30
Install the Runways
Your Lift has two Runways:
• Power Side Runway: Has the Lift’s Hydraulic Cylinder underneath it. Gets bolted into position.
Has a hole on the outside (on the Cylinder end) that lets you route the Hydraulic Hose, Air Lines,
and Return Line to the Power Unit. Lifting Cable routing ends under the Power Side Runway.
• Offside Runway: Gets bolted into position. Does not have a Hydraulic Cylinder under it, nor are
there any Lifting Cables under it.
Orient the two Runways this way:
• Utility Rails on the inside
• Find the Power Side Runway by looking under the two Runways (only the Power Side Runway has
a Hydraulic Cylinder underneath it) and put it next to the Power Post.
• There is also a ~1.5-inch-wide hole in the outside of the Power Side Runway near the Power Post.
There are other holes in the Runways, but they are smaller and used with accessories only.
The Ramp locations do not change based on Power Post location, but the location and orientation of
the Power Side Runway does.
The following drawing shows the correct orientation of the Runways for both Power Post locations.
Not to scale. Not all components shown. Tops of Runways not shown.
HD-75BXT Series Four-Post Lifts 30P/N 5900282 — Rev. A — February 2023
Page 31
Use a Forklift or Shop Crane to raise the Runways and move them into position.
⚠ WARNINGPay close attention when moving the Runways into position; they are heavy and
long, and could shift position or fall, potentially causing serious injury.
To install the Runways:
1. Correctly orient the Power Side Runway and the Offside Runway.
See the previous page for more information.
2. On the underside of the Power Side Runway, make sure the Sheaves have been removed.
3. Use a Forklift or Shop Crane to pick up the Power Side Runway and move it into place on the
Power Side of the Lift.
Make sure the Utility Rail is on the inside
4. Bolt the Power Side Runway into place, two Bolts on each end going into the Crosstubes.
5. Using a Forklift or Shop Crane, pick up the Offside Runway and move it into place.
Make sure the Utility Rail is on the inside
The following drawing shows the Offside Runway being installed in the Wide Setting.
6. Bolt the Offside Runway into place.
.
.
7. Make sure the Primary Safety Locks are engaged.
⚠ WARNINGDo not continue with the installation until you have visually confirmed that all four
Primary Safety Locks are engaged. If they are not engaged, the Runways could
move or fall, possibly causing personal injury (even death) or product damage.
HD-75BXT Series Four-Post Lifts 31P/N 5900282 — Rev. A — February 2023
Page 32
Install the First End of the Flex Tube
The Flex Tube is a flexible, black tube that attaches to an opening on the Power Side Runway at one
end and to the bottom of the Flex Tube Bracket Plate (near the Power Unit) on the other end.
The Flex Tube consolidates and protects three lines that come out from under the Power Side Runway
on their way to the Power Unit: the Return Line, the Air Line, and the Hydraulic Hose.
The following drawing shows the Flex Tube.
Not to scale. Not all components shown.
To install the Flex Tube to the Power Side Runway:
1. Install one Connector on the Power side Platform opening near
the Power Unit and secure. Refer to the figure on the right.
2. Holding the Flex Tube by the Plastic Collar, put the Threads on
the end of the Flex Tube through the hole on the side of the
Power Side Runway.
The Threads go into the hole until they are accessible from the
inside, the rest of the Flex Tube stays outside.
3. On the inside of the Power Side Runway, screw the Plastic Nut
back onto the Threads of the Flex Tube and tighten it.
4. Measure, mark, then cut the Flex Tube to a length of 52 (±1) in.
/ 1320 (±25) mm.
5. Install the second Connector on
the open end of the Flex Tube.
6. Let the end of the Flex Tube
hang in place for now.
HD-75BXT Series Four-Post Lifts 32P/N 5900282 — Rev. A — February 2023
Page 33
To extend the Piston
1.
2.
3.
4.
Extend the Piston
Before routing the Lifting Cables
:
Remove the Shipping Plug from the Return Line
Port on the Hydraulic Cylinder.
The Return Line Port is on the Cylinder end closest
to where the Power Unit will be.
Attach an air pressure source to the Return Line
Port and use the air pressure to extend the
Hydraulic Cylinder’s Piston;
.
psi
If the Cylinder does not move, stop using air
pressure; instead use a pulling device (such as a
Come Along Tool) to extend the Piston; be careful
not to damage the Piston.
Reinstall the Shipping Plug onto the Return Line
Port.
do not exceed 50
, extend the Piston on the Hydraulic Cylinder.
HD-75BXT Series Four-Post Lifts 33P/N 5900282 — Rev. A — February 2023
Page 34
Route the Lifting Cables
The figure below provides an overview of the routing for all four Lifting Cables. View this manual in
color at www.bendpak.com/car-lifts/four-post-lifts/
HD-75BXT Series Four-Post Lifts 34P/N 5900282 — Rev. A — February 2023
Page 35
HD-75BXT
Cable Description Part Number
A
B
C
D
To route Lifting Cables A and C:
1.
Starting with Lifting Cable A
through, near the bottom of Post A; verify you have the correct Lifting Cable.
2. Remove the Nut and Washer from the Threaded End (but keep it nearby, you will need it soon).
3. Route the Threaded End of Lifting Cable A into its Large Window on the Crosstube, push it
towards Post A, and then pull the Threaded End out of the Crosstube at the bottom of the Gusset.
4. Route the Threaded End of Lifting Cable A
reinstalled, then route it up towards the top of the Post past the top of the Crosstube Gusset.
Important: When routing a Lifting Cable in its Post, it must go
Ø10 x 3,228 mm 5595351
Ø10 x 5,471 mm 5595191
Ø10 x 8,570 mm 5595710
Ø10 x 9,293 mm 5595711
, move the entire Cable to just under the Large Window it goes
Sheave will be positioned then, when the Cable heads up toward the top of the
Post, it must run between the Gusset Sheave and the Slack Safety Sheave.
under
where the Gusset Sheave will go when it is
under
where the Gusset
Important: Before re-installing any Sheave, lubricate the Pin and Bearing using a liberal amount
of Red Lithium Grease.
5. With the Lifting Cable in place, reinstall the Gusset Sheave and the Cable Lock Pin in Post A.
6. Push the Threaded End of Lifting Cable A up to and through the Top Cap (at the top of the Post)
hand tighten
and
HD-75BXT Series Four-Post Lifts 35P/N 5900282 — Rev. A — February 2023
it in place with the Nut and Washer you removed earlier.
Page 36
Hand tighten the Nut at this point so that there is a little play in the cabling. We will securely tighten
all four Nuts later in the installation procedure.
Components removed for clarity. Not to scale.
7.
Switching to Lifting Cable C
, repeat Steps 1 through 7 for Lifting Cable C, starting at the
Small Window near the bottom of Post C (the Power Post).
8. Reinstall the Cable Sheave and then verify Lifting Cable C is correctly positioned in the Cable
Sheave in the Small Window.
9. Under the Power Side Runway, move the rest of Lifting Cable C back towards the Crosstube with
Large Windows.
10. Push Lifting Cables A and C into the Large Window where the Double Cable Sheave will be
installed and pull the Button ends towards the Cable Retainer.
11. With the Cables in place in the Large Window, reinstall the Double Cable Sheave; make sure Lifting
Cable A is set in the Bottom Cable Sheave, and Cable C is in the top Sheave.
HD-75BXT Series Four-Post Lifts 36P/N 5900282 — Rev. A — February 2023
Page 37
Components removed for clarity. Not to scale.
12. Near the Hydraulic Cylinder, loosen the Retaining Plate enough to give you room to slip the Button
End of each Cable into its location on the Retainer Block.
Do not remove the Retaining Plate off
, just loosen the Retaining Plate enough to slip the
Button End of each Lifting Cable into place.
13. Pull the Button Ends of Lifting Cables A and C back towards the middle of the Runway, past the
Retaining Plate, and into its slot on the Cable Retaining Block.
Not to scale. Components removed for clarity.
HD-75BXT Series Four-Post Lifts 37P/N 5900282 — Rev. A — February 2023
Page 38
NoteRouting Lifting Cables B and D is the same process as routing Lifting Cables A and C, just to
the other two Posts and using a different set of Sheaves. Refer to the drawings in the
previous section.
Install the Power Unit
This section describes how to
not
An Electrician is
the Power Unit to its power source.
The Power Unit
whichever is more convenient for the location.
Important: Many people install the Flex Tube Bracket Plate and/or the Zero Angle Bracket at the
needed to install the Power Unit; however, an Electrician is required to connect
must
be installed on the Power Post: attach it to one of the two Mounting Brackets,
same time as they install the Power Unit. Read Installing the Second End of the
Flex Tube and Installing the Pushbutton Air Valve for more information to see
if this makes sense for your installation.
install
, but not make the connections to, the Power Unit for your Lift.
⚠ DANGERRisk of explosion: The Power Unit has internal arcing or parts that may spark and
should not be exposed to flammable vapors. Never expose the Power Unit motor
to rain or other damp environments. Damage to the motor caused by water is
covered by the warranty.
TipThe Power Unit is heavy. BendPak recommends having one person hold the Power Unit
while another person bolts it into place.
To install the Power Unit:
1. Find the four supplied Hex Head Bolts, Flat Washers, Nyloc Nuts, and the Vibration Dampener.
2. Line up the holes on the Vibration Dampener with the four holes in the Mounting Bracket.
not
3. If you are going to install the Flex Tube Bracket Plate and/or the Zero Angle Bracket at the same
time as the Power Unit, now is the time to put them into place.
4. Put a Flat Washer onto each of the four Hex Head Bolts, slide the Bolts through the back of the
Mounting Bracket and through the holes in the Vibration Dampener, then put on the Nyloc Nuts to
secure the Power Unit in place.
HD-75BXT Series Four-Post Lifts 38P/N 5900282 — Rev. A — February 2023
Page 39
IMPORTANT! PLEASE READ NOW
Hydraulic Fluid Contamination
Hydraulic Fluid Contamination poses a serious issue for your Lift; contaminants such as water, dirt, or
debris can get into the Hydraulic Hoses and Fittings on your Lift, making your new Lift inoperable.
Your Lift is shipped with clean components; however, BendPak strongly recommends that you clean
all Hydraulic Hoses and Fittings prior to making connections. It is better and less costly to take these
extra steps now so that you do not need to take your Lift out of service later to fix issues that could
have been prevented at the time of installation.
There are several ways to clean Hydraulic Hoses and Fittings:
• Compressed Air. Use an air compressor to blow out contaminants from each Hydraulic Hose
and Fitting prior to installation. Use clean, dry air. Wear eye protection (safety glasses, goggles, or
face shield) when using compressed air for cleaning. Never point an air hose nozzle at any part of
your body or any other person.
• Fluid Flushing. As long as the Hydraulic Fluid is clean and compatible with the system fluid, you
can flush Hoses and Fittings to create turbulent flow and remove particulates. Always ensure that
the fluid itself is contaminant-free.
Some additional steps that will help keep the Hydraulic Fluid clean:
• Remove old thread seal tape. Some ports on the Hydraulic Cylinders are shipped with
temporary plugs secured with thread seal tape, so make sure to thoroughly remove any leftover
thread seal tape that may inadvertently enter the Hydraulic System.
• Use a liquid thread sealant only. Teflon paste-type thread sealant or Loctite™ 5452 thread
sealant is recommended for all NPT Fittings. Do not over tighten NPT Fittings or they may crack.
Never use thread seal tape on JIC Fittings or ORB O-Ring Fittings.
• Always use clean equipment. If you use a dirty bucket or funnel to transfer the Hydraulic Fluid
into the Hydraulic Fluid Reservoir, the contaminants will likely be introduced into the Fluid. When
using cleaning rags, use a lint-free rag.
• Proper storage. Keep the Hydraulic Fluid sealed in its container until ready for use; store the
Fluid in a clean, dry, and cool area.
• Cover the Hoses and Fittings. Before installation, do not leave the ends of the Fittings
exposed; the same applies for the Hydraulic Hoses. As a general rule, keep the Hydraulic Hoses
and Fittings capped and kept clean in a clean area until ready for use.
• Filter the new Hydraulic Fluid. New does not necessarily mean clean. Use an offline filtration
cart or kidney loop system to make sure the Hydraulic Fluid is clean before being transferred into
the Hydraulic Fluid Reservoir (even using a heavy-duty nylon mesh screen is better than trusting
what is left at the bottom of the barrel).
• Avoid mixing different types of Hydraulic Fluid. If Hydraulic Fluid needs to be replaced,
make sure to flush the Hydraulic System of the old Hydraulic Fluid before you add the replacement
Fluid; do not mix the two together.
HD-75BXT Series Four-Post Lifts 39P/N 5900282 — Rev. A — February 2023
Page 40
Hydraulic System Warnings
Before applying power to the Hydraulic System note the following Warnings:
WARNING Failure to observe these warnings can result in serious personal injury including, in
⚠
rare cases, death.
⚠WARNINGThe Hydraulic hoses and connections must be inspected before any attempt to
raise a Vehicle is made.
⚠WARNING
Verify all
plugs on the Power Unit, the Cylinders and anywhere else in the Hydraulic System
are tightened.
Hydraulic Hose connections and fittings, including unused auxiliary port
⚠WARNINGThe Power Unit is a Hydraulic Pump capable of developing pressures in excess of
5,000 psi (345 BAR). A pressure relief valve is used to set the pressure at the
desired level. Tampering with, adjusting, modifying, or removing the relief valve is
extremely dangerous and is not recommended. Only trained Hydraulics technicians
should adjust the relief valve, using calibrated hydraulic pressure gauges to assure
the proper pressure setting is achieved.
⚠WARNING Changes to the output pressure may render the Power Unit incompatible with
pressure limitations on other components in the hydraulic circuit. This may cause
catastrophic failure of those components, and could result in property damage,
serious personal injury or death.
⚠WARNING The Hydraulic System can contain high pressure which, if suddenly released, can
cause serious injury or death.
⚠WARNING Do not attempt to connect or disconnect Hydraulic Hoses while the equipment is
loaded or while a Vehicle is on the Lift or the Hydraulic System is under pressure.
⚠WARNING Keep bare hands away from Hydraulic Fluid; always wear gloves when handling
Hydraulic Fluid, Cylinders or Hydraulic Hoses.
⚠WARNING When handling Hydraulic Fluid, always observe the safety instructions from the
manufacturer.
⚠WARNING Always promptly clean any Hydraulic Fluid spills. If a leak in the system is the
source of the spill, lockout the Lift to prevent use until the Hydraulic System is
repaired.
HD-75BXT Series Four-Post Lifts 40P/N 5900282 — Rev. A — February 2023
Page 41
About Thread Sealants
Liquid Thread Sealant lubricates and fills the gaps between the Fitting threads, and leaves no residue
that could contaminate the Hydraulic Fluid. Other types of Thread Sealants (like Teflon Tape) can shred
during installation or removal and eventually enter the Hydraulic System.
Thread Sealant can be used with most Hydraulic Fittings, although you probably only need to use with
NPT connectors.
To apply Thread Sealant:
1. Make sure the Fittings and connectors you are going to use are clean and dry.
If you are adding Thread Sealant to a Fitting or connector that has already been used with a
different sealant, use a wire brush to thoroughly remove the old sealant before adding more.
2. Apply a small amount of Thread Sealant to the first four threads of the Fitting.
⚠ WARNING Always wear the proper protective equipment when handling Thread Sealant.
You only need a small amount because the sealant spreads to the other threads as it is tightened
into place.
If you put too much, the excess liquid will be pushed out when the Fitting is tightened; use a rag to
wipe the excess.
3. Tighten the Fitting into the connector; do
4. Allow the manufacturer-recommended curing time before pressurizing the system.
not
over tighten the Fitting.
Fill the Hydraulic Fluid Reservoir
The Hydraulic Fluid reservoir on the Power Unit must be filled with Hydraulic Fluid or automatic
transmission fluid before you begin normal operation of the Lift.
When you receive the Lift, the
fluid reservoir is empty.
The Power Unit will
Approved fluids are any general purpose ISO-32, ISO-46, or ISO-68 hydraulic fluid, approved
automatic transmission fluids such as Dexron III, Dexron VI, Mercon V, Mercon LV, or any synthetic
multi-Vehicle automatic transmission fluid.
not
work correctly until it is filled with approved Hydraulic Fluid.
⚠ WARNING Do not run your Power Unit without Hydraulic Fluid; you will damage it.
To fill the Reservoir with Hydraulic Fluid:
1. Remove the Reservoir Cap and set it aside.
Make sure to keep the Reservoir Cap clean; you do not want any contaminants getting into the
Hydraulic Fluid Reservoir.
2. Fill the Hydraulic Fluid Reservoir on the Power Unit with the appropriate amount of approved fluid.
Several power units are available. The fluid capacity of several common units are detailed below.
Always refer to your actual unit for the exact capacity.
The Hydraulic Reservoir holds from 3.5 to 4.5 gallons, depending on your Power Unit:
– 5585280: 3.7 gallons / 14 liters
– 5585247: 3.7 gallons / 14 liters
– 5585106: 3.5 gallons / 13.25 liters
HD-75BXT Series Four-Post Lifts 41P/N 5900282 — Rev. A — February 2023
Page 42
– 5585014: 3.7 gallons / 14 liters
Use care to keep the fluid clean when filling the reservoir.
Do not connect the Power Unit to a power source at this point.
3. Replace the Reservoir Cap.
Install the Second End of the Flex Tube
Once the Power Unit is installed, you can install the second end of the Flex Tube (the other end was
connected to the Power Side Runway earlier in the installation).
To install the Flex Tube:
1. Find the Flex Tube Bracket Plate and the Flex Tube Angle Plate. The Flex Tube is already nearby.
2. Install the Flex Tube Bracket Plate.
Note: It is common to install the Flex Tube Bracket Plate between the Mounting Bracket and
the Back Plate. This allows the Zero Angle Bracket (which holds the Pushbutton Air Valve
and is described in the next section) to be installed between the Back Plate and the
retaining Nut. This configuration is common, but it is not required.
Side view of where the Power Unit attaches to the Power Post. Power Unit not shown.
3. Connect the Flex Tube Angle Plate to the Flex Tube Bracket Plate so that the hole for the Flex
Tube is best positioned for connecting the Return Line, the Air Line, and the Hydraulic Hose.
The Flex Tube Angle Plate can be connected on either side of the Flex Tube Bracket Plate.
HD-75BXT Series Four-Post Lifts 42P/N 5900282 — Rev. A — February 2023
Page 43
4. When the Flex Tube Angle Plate is in place, unscrew the
Plastic Nut from the end of the Flex Tube.
5. Holding the Flex Tube by the Plastic Collar, put the Threads
through the hole on the Flex Tube Angle Plate
underneath
6. Screw the Plastic Nut back onto the threads and tighten.
.
from
Working with Compression Fittings and
Tubing
Your Lift comes with a roll of ¼ inch, black, polyethylene Tubing
(also called Poly-Flo® Tubing) that is used with Compression
Fittings in two ways: for the Return Line and for the Air Lines.
Important: While both lines use Tubing and Compression
Fittings, the Return Line and Air Lines are used for
completely separate purposes; do not connect the two together.
Note: Compression Fittings are different from Hydraulic Fittings. This section covers Compression
Fittings only.
The components involved with Compression Fittings include:
• ¼ inch, black, polyethylene Tubing. Use a single piece of Tubing for the Return Line. The
Air Lines require multiple Tubing pieces. Create the Tubing pieces for both the Return Line and the
Air Lines by cutting lengths from the long roll of Tubing supplied with your Lift.
• Elbow Compression Fittings. The Return Line uses two Elbow Compression Fittings, one at
each end.
• Tee Compression Fittings. The Air Lines require three Tee Compression Fittings.
• Nuts, Ferrules, Rods, and Threads. Each connector on Elbow and Tee Compression
Fittings have a Nut, Ferrule, Rod, and Threads (see drawing below). The Nut holds the Tubing and
Fitting together. The Ferrule compresses when you tighten the Nut on the Threads to make a
secure connection. The Rod goes inside the Tubing so that nothing leaks out.
The following drawing shows the components of a connector on a Tee Compression Fitting.
Important:
Ferrules can only be tightened once
the Ferrule is compressed; the Ferrule may not be reused after this compression.
. When you tighten the Nut on the Threads,
To connect Tubing to a Compression Fitting:
1. Push the Tubing through the Nut and over the Rod.
Do not push hard; you only need the Tubing to go a little way over the Rod. You cannot see the
Ferrule at this point, but the Tubing must go through the Ferrule and over the Rod.
HD-75BXT Series Four-Post Lifts 43P/N 5900282 — Rev. A — February 2023
Page 44
2. Slide the Nut on the Tubing
from the Threads and then slide it away from the Fitting. See the drawing above.
3. Slide the Ferrule over the Tubing, away from the Fitting and towards the Nut.
4. With the Nut and the Ferrule out of the way, push the Tubing farther over the Rod until it stops.
5. Slide the Ferrule and the Nut back to the Threads on the Fitting.
The Ferrule goes around the Rod and under the Threads. The Nut goes onto the Threads.
6. Tighten the Nut.
Remember that the Ferrule can only be used once; do not tighten the Nut until everything is
ready.
away from the Fitting
; if the Nut is still on the Threads, unscrew it
Install the Pushbutton Air Valve
The Pushbutton Air Valve is used to lower the Runways. It can go on either side of the Power Unit,
whichever is easier to access for the Lift operator.
Once the pushbutton is in place, you need to connect it to both the Air Line (which is coming out of the
Flex Tube) and the customer-supplied air pressure.
psi) is required.
The following drawing shows the Zero Angle Bracket and where it connects.
An Air Supply (3 to 25 cfm at 50 to 150
The following figure details the Pushbutton Air Valve and its connections.
HD-75BXT Series Four-Post Lifts 44P/N 5900282 — Rev. A — February 2023
Page 45
The components involved include:
• Zero Angle Bracket. Attaches at the Mounting Bracket on the Power Post or to other available
holes on the Back Plate of the Power Unit. Holds the Pushbutton Air Valve, so be sure to orient the
Zero Angle Bracket so that the Pushbutton Air Valve can be easily reached by the Lift operator.
• Pushbutton Air Valve. Used to lower the Runways.
• Air Line Compression Elbow Fitting. Connects the Pushbutton Air Valve to the Air Line
coming out of the Flex Tube.
• Straight Expander Fitting. Connects the Pushbutton Air Valve to the customer-supplied air
pressure.
To install the Pushbutton Air Valve:
1. Find the necessary components: Zero Angle Bracket, Pushbutton Air Valve, Air Line Compression
Elbow Fitting, and Straight Expander Fitting.
2. Connect the Zero Angle Bracket at the desired location (if it has not already been connected).
It can attach to an available hole on the Back Plate of the Power Unit or to one of the Bolts that
connect the Power Unit to the Mounting Bracket on the Power Post.
3. Connect the Pushbutton Air Valve to the Zero Angle Bracket.
Use the two holes on the Pushbutton Air Valve on the side away from the actual pushbutton. If
you use the holes next to the pushbutton, the Zero Angle Bracket interferes with the pushbutton
when you try to use it.
4. Connect the Air Line Compression Elbow Fitting and the Straight Expander Fitting to the
appropriate locations on the Pushbutton Air Valve.
The elbow fitting connects to the opening labelled CYL. The straight fitting to the opening labelled
IN. See the drawing above.
5. Attach the Air Line (coming out of the Flex Tube) to the compression fitting on the elbow fitting
and the customer-supplied air to the straight fitting.
Important: The Return Line also comes out of the Flex Tube and is the same kind of tubing as the
Air Line.
mistake
Do not attach the Return Line to the Pushbutton Air Valve by
. Double check to make sure you are attaching the Air Line to the Pushbutton
Air Valve.
HD-75BXT Series Four-Post Lifts 45P/N 5900282 — Rev. A — February 2023
Page 46
Install the Air Lines
This section describes how to install the Air Lines, but not how to connect them to the Power Unit (as
it is not yet installed).The Air Lines use air pressure to disengage the Safety Locks so you can lower the
Runways.
You will need more of the ¼ inch, black, polyethylene Tubing that came with the Lift and three Air Line
Tee Connectors to install the Air Lines.
An Air Supply (3 to 25 cfm at 50 to 150 psi) is required to disengage the Safety Locks. Regulate the
line to a maximum pressure of 150 psi.
⚠ CAUTIONDo not let the Air Supply exceed 150 psi; the Air Lines could burst or the Safety
Locks malfunction.
Important: Do not confuse the Air Lines with the Return Line. They use the same ¼-inchTubing
and fittings, but they are used for completely different things; the two systems
be connected to each other.
not
must
Drawing not to scale. Some components not shown. Air Lines shown outside Steel Tubes for clarity.
HD-75BXT Series Four-Post Lifts 46P/N 5900282 — Rev. A — February 2023
Page 47
The Air Line Elbow Connectors on the Air Cylinders come installed from the factory.
Important: Do not confuse the Air Lines with the Return Line. They use the same Tubing and
fittings, but they are used for completely different things; the two systems
be connected to each other.
To install the Air Lines:
1. Find the roll of supplied ¼-inch, black, polyethylene Tubing and three Air Line Tee Connectors.
2. Measure the distances for each of the seven (7) Tubing pieces you will need (see the drawing on
the previous page).
3. Cut seven pieces of Tubing to the measured lengths from the roll of Tubing.
4. Connect the various pieces of Tubing to the Air Line Tee Connectors on the Lift.
Refer to the drawing on the previous page for the locations of the Tubing pieces.
must not
Make sure to position the three Air Line Tee Connectors as shown in the
drawing
Also make sure to route the long Tubing piece that goes under the Power Side Runway through
the Retaining Rings. Verify the Air Lines do not interfere with the Lifting Cables.
.
⚠CAUTIONMake sure to route the Tubing pieces on the
Crosstubes through the Steel Tubes welded on the Crosstubes. This keeps the
Tubing and the Tee Connectors from being disturbed as you use the Lift. This is
important, because if the Air Lines are damaged, the Safety Locks on the Lift may
not work correctly. If you notice that Tubing has become disconnected from an Air
Line Tee Connector, take the Lift out of service, and repair the Air Lines.
Refer to Working with Compression Fittings and Tubing for more information about
connecting the Tubing to the Air Line Tee Connectors.
5. Leave the Power Unit end of the Air Line hanging out of the Flex Tube for now.
It will be connected to the Pushbutton Air Valve later in the installation process.
outside
of the Front and Rear
HD-75BXT Series Four-Post Lifts 47P/N 5900282 — Rev. A — February 2023
Page 48
To install the Return Line
1.
2.
3.
4.
5.
6.
Install the Return Line
The Return Line routes excess Hydraulic Fluid from the Hydraulic Cylinder and sends it back into the
Fluid Reservoir on the Power Unit.
The Return Line is a single piece of ¼-inch, black, polyethylene Tubing with Elbow Compression
Fittings on each end.
Important: The Return Line uses the same ¼-inch, black, polyethylene Tubing as the Air Lines. Be
sure not to confuse the two: the Return Line and the Air Lines do completely different
must
things and
The following drawing shows how to connect the Return Line.
Measure the distance from the
Return Line Port on the Hydraulic
Cylinder to the Hydraulic Return
Port on the Power Unit.
be kept separate from each other.
:
Cut a piece of Tubing to the
measured length from the roll of
Tubing that comes with the Lift.
It is better to cut the Tubing a little
too long rather than a little too short.
Route the Tubing from the Hydraulic
Cylinder, through the Retaining
Rings on the underside of the Power
Side Runway, through the Flex
Tube, and out next to the Power
Unit mounting.
Remove the Shipping Plug from the
Return Line Port on the Hydraulic
Cylinder.
Connect and tighten the NPT end of
the Elbow fitting to the Return Line
Port and the COMP end connects
to one end of the Return Line.
Use Liquid Thread Sealant on
NPT threads only
Refer to Working with
Compression Fittings and
Tubing for instructions.
.
Take the second Compression
Elbow Fitting and connect the NPT
end to the Power Unit, and the
COMP end to the other end of the
Return Line (coming out of the Flex
Tube).
HD-75BXT Series Four-Post Lifts 48P/N 5900282 — Rev. A — February 2023
Top View of Power Side Runway. Drawing not to scale.
Some components not shown or exaggerated for clarity.
Page 49
To install the Hydraulic Hose
1.
2.
3.
4.
5.
6.
7.
8.
Install the Hydraulic Hose
The Hydraulic Hose moves Hydraulic Fluid from the Power Unit to the Hydraulic Cylinder.
The following drawing shows how to connect the Curved End of the Hydraulic Hose to the Hydraulic
Cylinder.
Find the Hydraulic Hose and two
Hydraulic Fittings.
Push the Hydraulic Hose through the
Flex Tube with the Curved end going
to the Hydraulic Cylinder and the
Straight end going to the Power Unit.
Make sure to route the Hydraulic
Hose through the Retaining Clips
along the side of the Runway.
On the Hydraulic Cylinder, remove
the Shipping Plug from the Port at the
Piston / Retainer Block end.
:
Attach the NPT connector of the
JIC x NPT Fitting to the Hydraulic
Cylinder Port (where you just
removed the Shipping Plug) and
tighten it.
Use Liquid Thread Sealant on
the NPT threads only
Tip Leave the JIC end pointing
up; this will direct the
Hydraulic Hose up and away
from where the Lifting
Cables will be installed.
Attach the Curved end of the
Hydraulic Hose to the JIC connector
that is facing up and tighten it.
Locate the Hydraulic Pressure Port
on the Power Unit and remove the
Shipping Plug.
See Connecting to a Power
Source for Port locations.
Connect the ORB end of the ORB x
JIC Fitting to the Power Unit Port and
the JIC end to the Straight end of the
Hydraulic Hose.
Securely tighten all connections.
.
Top view of the Power Side Runway. Drawing not to scale.
Some components not shown or exaggerated for clarity.
HD-75BXT Series Four-Post Lifts 49P/N 5900282 — Rev. A — February 2023
Page 50
Contact the Electrician
As mentioned previously, there are installation tasks that
⚠ DANGERAll wiring
The Electrician needs to:
• Connect the Power Unit to an appropriate power source. A power source is required.
Refer to Connecting to a Power Source for more information.
• Install a Power Disconnect Switch. Ensures you can completely interrupt electrical power to
the Lift in the event of an electrical circuit fault, emergency situation, or when equipment is
undergoing service or maintenance. You must put it within sight and easy reach of the Lift
operator. Refer to Install a Power Disconnect Switch for more information.
• Install a Thermal Disconnect Switch. Ensures the equipment shuts down in the event of an
overload or an overheated motor. Refer to Install a Thermal Disconnect Switch for more
information. Note that the Power Unit that comes with the Lift is
The electrician is responsible for providing:
• an appropriate cable and plug to attach to the Power Unit, for connection to a wall outlet
appropriately protected wiring that attaches the Power Unit to the facility’s electrical system
protected by an appropriate circuit breaker.
• a Power Disconnect Switch
• a Thermal Disconnect Switch
must
be performed by a licensed Electrician.
require
a licensed Electrician.
not
thermally protected.
or
Electrical Information
• Improper electrical installation can damage the Power Unit motor, which is not covered by the
warranty.
• The Lift uses electrical energy; if your organization has Lockout/Tagout policies, make sure to
implement them after connecting to a power source.
• Use a separate circuit breaker for each Power Unit.
• Protect each circuit with a time delay fuse or circuit breaker:
Connect to a Power Source
⚠ DANGERAll wiring
maintenance or installation on the Lift without first making sure that main electrical
power has been disconnected from the Lift and cannot be re-energized until all
procedures are complete. The Lift uses electrical energy; if your organization has
Lockout/Tagout policies, make sure to implement them after connecting to a power
source.
Important: Make clear to your Electrician that all electrical work
state, and federal codes, rules, and regulations, such as state and federal OSHA
regulations and electrical codes.
To connect the Lift to a power source:
must
be performed by a licensed Electrician. Do not perform any
must
conform to applicable local,
1. Locate the Pigtail coming out of the Electrical Box on the Power Unit.
HD-75BXT Series Four-Post Lifts 50P/N 5900282 — Rev. A — February 2023
Page 51
⚠
2. Open the Electrical Box,
the facility’s electrical system or wire a power cord with appropriate plug inside the Electrical box
where the Pigtail was wired.
Wiring information is either on the outside of the Power Unit under the Electrical Box or inside the
cover of the Electrical Box. Have the Electrician use that wiring information to wire the Power Unit
to the power source.
You can also find the Wiring Diagram for your Power Unit in Wiring Diagrams.
3. Close the Electrical Box.
remove the Pigtail
, and then either wire the Power Unit directly into
Install a Power Disconnect Switch
WARNING A main Power Disconnect Switch is
not
provided with this equipment.
A Power Disconnect Switch is a National Electrical Code
(NEC) requirement. They are designed to interrupt
electrical power in the event of an electrical circuit fault,
emergency situation, or when equipment is undergoing
service or maintenance.
BendPak strongly recommends that you install a Power
Disconnect Switch that is properly rated for the
incoming power.
⚠ DANGERAll wiring
licensed Electrician.
Your Power Disconnect Switch must be readily
accessible and installed so that it is within easy reach of
the Lift operator. It must be clearly and legibly marked to
indicate its purpose.
The figure to the right shows a toggle Power Disconnect
Switch between the Lift’s power source and its Power
Unit. A quick flip of the switch immediately cuts power to
the Lift.
Make sure to have a licensed Electrician install the
Power Disconnect Switch.
Make sure the Electrician installs a UL-listed Power
Disconnect Switch.
must
be performed by a
Install a Thermal Disconnect Switch
⚠ WARNING The Lift’s motor does
Connect a motor Thermal Disconnect Switch or overload device that will make sure the equipment
shuts down in the event of an overload or an overheated motor.
⚠ DANGERAll wiring
HD-75BXT Series Four-Post Lifts 51P/N 5900282 — Rev. A — February 2023
must
be performed by a licensed Electrician.
not
have thermal overload protection.
Page 52
Electrical current that exceeds the motor’s full load amperage rating (FLA) may result in permanent
not
damage to the motor. BendPak strongly recommends you
Lift’s motor.
exceed the rated duty cycle of the
About Effective Embedment
Anchor Bolts achieve their holding strength from the depth at which the Anchor Bolt’s Expansion
Sleeve presses into the Concrete (Effective Embedment) and how forcefully the Expansion Sleeve
presses into the Concrete (based on the width of the hole and Torque applied).
The deeper the Expansion Sleeve, the greater the Effective Embedment, thus the greater the holding
strength of the Anchor Bolt. The hole should be drilled at the same diameter as the Anchor Bolt with
no wobbling. The correct amount of Torque is a small range; exceeding the recommended Torque
value may damage the concrete and reduce the Anchor Bolt’s holding strength.
Note: Do not confuse Effective Embedment with Nominal Embedment, which is how far down into
not
the Hole the bottom of the Anchor Bolt is. The two are
does not tell you anything about the holding strength of the Anchor Bolt. carefully follow the
specifications and instructions in Anchoring the Posts.
the same; Nominal Embedment
⚠ WARNING Use only the Anchor Bolts that came with your Lift. Only install your Lift on a
Concrete floor. Make sure to get the correct amount of Effective Embedment and
use the correct amount of Torque.
HD-75BXT Series Four-Post Lifts 52P/N 5900282 — Rev. A — February 2023
Page 53
Concre
•
•
•
Anchor the Posts
After anchoring the Lift’s four Posts, install one Anchor Bolt in each corner of each Base Plate, 16
Anchor Bolts total. Note that anchoring is optional.
te specifications are:
Depth: 4.25 in (108 mm) thick
PSI: 3,000 PSI, minimum
Cured: 28 days, minimum
⚠ WARNING Your Concrete and Anchor Bolts
Lift on a Concrete surface. If you install a Lift on asphalt or any other surface, or
your Concrete or Anchor Bolts do not meet these specifications, it could lead to
product damage, Vehicle damage, personal injury, or even loss of life.
BendPak Lifts are supplied with installation instructions and Concrete fasteners meeting the criteria as
prescribed by the current version of the American National Standard “Automotive Lifts – Safety
Requirements for Construction, Testing, and Validation” ANSI/ALI ALCTV.
Anchor Bolt specifications are:
• Length: 4.75 in (120.5 mm)
• Diameter: .75 in (19 mm)
• Anchor Torque: 85 – 95 pound feet (do not
Torque less than 80 or more than 105)
must
meet these specifications. Only install your
⚠ WARNING Use only the Anchor Bolts that came with your Lift. If you use components from a
different source, you void your warranty and compromise the safety of everyone
who installs or operates the Lift.
Lift buyers are responsible for conforming to all regional, structural, and seismic anchoring
requirements specified by any other agencies and/or codes, such as the Uniform Building Code and/or
International Building Code.
To anchor the Posts:
1. Locate the hardware you will need: four Anchor Bolts, four Nuts, and four washers
2. Using the Base Plates as guides, drill the holes for the Anchor Bolts—one hole in each corner of
the Base Plate, to have four holes total per Base Plate.
Drill straight, in the center of the hole; do not let the drill
wobble.
Use a carbide bit (conforming to ANSI B212.15).
The diameter of the drill bit must be the same as the
Important: The holding strength of an Anchor Bolt is partly based on the how cleanly the
Expansion Sleeve presses against the Concrete. If the hole is dirty, the Expansion
Sleeve does not press as cleanly. If the hole is too wide, the Expansion Sleeve does
not press with as much force. Both result in less holding strength.
diameter of the Anchor Bolt. If you are using a ¾ inch
diameter Anchor Bolt, for example, use a ¾ inch diameter
drill bit.
per Post
.
HD-75BXT Series Four-Post Lifts 53P/N 5900282 — Rev. A — February 2023
Page 54
3. Vacuum each hole clean.
BendPak recommends using a vacuum to get the hole
very clean. You can also use a wire brush, hand pump, or
compressed air; just
clean each hole
Do
not
ream the hole. Do
than the drill bit made it.
4. Plumb each Post; install any needed Shims.
Do not shim a Post more than half an inch using the provided Shims. A maximum of 2 inches is
possible by ordering optional Shim Plates. Contact BendPak at (800) 253-2363, extension 191
to order. Please have the model and serial number of your Lift available.
make sure to thoroughly
.
not
make the hole any wider
Take your time while plumbing and shimming the Posts;
level as possible.
5. Make sure the Washer and Nut are in place,
the Anchor Bolt
6. Hammer or mallet the Anchor Bolt the rest of the way down into the hole.
Stop when the Washer is snug against the Base Plate.
7. Torque each Nut
a Torque Wrench.
with the top of the Nut flush with the top of
, then insert the Anchor Bolt into the hole.
The Expansion Sleeve of the Anchor Bolt may prevent the
Anchor Bolt from passing through the hole in the Base
Plate too far; this is normal.
Even using a hammer or mallet, the Anchor Bolt should
only go into the hole part of the way; this is normal. If the
Anchor Bolt goes all the way in with little or no resistance,
clockwise
to the recommended installation torque, 85 – 95 pound feet, using
the hole is too wide.
Once past the hole in the Base Plate, the Anchor Bolt
eventually stops going down into the hole as the Expansion
Sleeve contacts the sides of the hole; this is normal.
it is important to make the Lift
not
Important: Do
Anchor Bolts.
Do not torque past 105 pound feet; you could damage the
Concrete.
HD-75BXT Series Four-Post Lifts 54P/N 5900282 — Rev. A — February 2023
Wrenching the Nut forces the Wedge up, forcing out the
Expansion Sleeve and pressing it tightly against the
Concrete.
use an impact wrench to torque the
Page 55
Final Leveling
It is very important that the Lift’s Runways are level, or as close to level as possible. The following
procedure describes how to fine tune how level your Lift is.
The goal is that the four Safety Locks on the Lift engage at the same time.
To complete a final leveling on the Lift:
1. Raise your Lift to the first Safety Lock position (the Primary Safety Locks, not the Slack Safety
Locks).
2. Use a transit level or other leveling mechanism to evaluate how level the Posts and Runways are
to each other.
3. If you need to adjust a Runway, use the Top Nut and Stop Nut on the Top Cap of each Post to
make adjustments to the Ladder in that Post (which impacts the levelness of the Runway and
when the Safety Locks engage).
4. Raise the Lift to full height, listening as the Safety Locks engage.
If you hear the Safety Locks engaging at the same time, no further adjustments are necessary.
If the Safety Locks are not engaging at the same time, check the leveling, make necessary
adjustments, and then raise the Lift again and listen as the Safety Locks engage.
5. When you are satisfied the Lift is level, firmly secure the Nuts at the top of each Post.
Install Accessories
The accessories available for your Lift include:
• Boat Trailer Tongue Platform (TC-3000 model). Is intstalled between the Runways, holds the
front Jack of your boat trailer.
• Gusset Covers. Yellow, Plastic Covers that are installed on top of the Crosstube Gussets.
• Tire Stops. Installed at the Front of the Lift. Holds the Tires of the Vehicle in position. BendPak
recommends chocking the rear Tires, so that the Vehicle stays in place. Included with the Lift.
• Ramps. Installed at the Rear of the Lift. Allows Vehicles to be easily driven onto the Runways.
Included with the Lift.
• Anti-Slip Tape. Designed to increase friction between the metal surface of the Lift Ramps and
Vehicles or personnel on the Lift.
• Caster Kit. (Purchased separately) Allows the Lift to be moved to another location.
HD-75BXT Series Four-Post Lifts 55P/N 5900282 — Rev. A — February 2023
Page 56
Boat Trailer Tongue Platform
The Boat Trailer Tongue Platform extends outward 20 inches, from 48 to 68 inches between the
Runways.
The Boat Trailer Tongue Platform can support up to 3,000 lbs.; do
To install the Boat Trailer Tongue Platform:
1. Locate the Boat Trailer Tongue Platform.
2. Have two people
Lift’s two Runways.
3. Lower the Boat Trailer Platform to just above the Utility Rails, and adjust the Extendable Bases out
to the correct width.
4. Lower the Boat Trailer Platform onto the Utility Rails, making sure that the Extendable Bases are
securely in the Utility Rails.
carefully
raise the Boat Trailer Platform and orient it appropriately between the
not
exceed the rated capacity.
Gusset Covers
Gusset Covers go on top of the Crosstube Gussets; one per Crosstube. 4 Gusset Covers total.
To install the Gusset Covers:
1. Locate the four Plastic Covers from the Parts Box that came with your Lift.
2. Align the Covers with the openings in the Gusset, one at each end of the Crosstube, then push
the Cover into place.
Do the same for the remaining covers.
HD-75BXT Series Four-Post Lifts 56P/N 5900282 — Rev. A — February 2023
Page 57
Tire Stops
Tire Stops are attached on the Front of the Lift. They prevent the tires of the Vehicle on the Lift from
trvelling too far forward.
To install the Tire Stops:
1. Locate the two Tire Stops, two Tire Stop Pins, and four Rotor Clips.
2. Put one Tire Stop in position between the Tubes attached to the Runway, then put the Tire Stop
Pin all the way through the Tire Stop and the Tubes.
3. Secure the Tire Stop with Rotor Clips on each end of the Tire Stop Pin.
4. Repeat Steps 2 and 3 for the second Tire Stop.
Ramps
Your Lift comes with two steel Ramps, for driving Vehicles onto the Runways.
To install the Ramps:
1. Find the required components: two Ramps, two Ramp Pins, and four Rotor Clips.
2. Put a Ramp into position on the end of a Runway at the Rear of the Lift, with the Tube on the
bottom of the Ramp between the two Tubes on the end of the Runway.
3. Slide a Ramp Pin through the three Tubes, then install Rotor Clips on both ends of the Ramp Pin.
Note: The Ramps are heavy and awkward, so you may want to consider having two people
install them; one to hold the Ramp, the other to put the components into place.
4. Repeat Steps 2 and 3 for the other Ramp.
HD-75BXT Series Four-Post Lifts 57P/N 5900282 — Rev. A — February 2023
Page 58
Anti-Slip Tape
Anti-Slip Tape is designed to increase friction between the metal surface of the Lift Ramps and
Vehicles or personnel on the Lift. The Anti-Slip Tape is provided in a single roll measuring 6 in. x 24 ft.
(152 mm x 7.3 m). BendPak suggests cutting the Tape into four equal lengths 72 in. (1,829 mm) long.
IMPORTANT! Surface preparation is critical. If the runway is in poor condition with gouges, holes,
or jagged edges, the Anti-Slip Tape will not adhere. Lift Runways must be clean,
dry, and smooth. No grease or oil should be on the Ramp surface.
To apply the Anti-Slip Tape:
1. Clean the runway. Use a broom or brush to remove loose dirt and debris from the runway.
2. Thoroughly wash, rinse, and dry the runway using a mild solution of soap and clean water to
remove any oils, grease, and water-soluble contamination. Dry the runway with a clean cloth and
allow to air dry.
3. Cut the Anti-Slip Tape into four equal pieces. Suggested length is 72 in. (1,829 mm).
4. Verify the Runway is dry and clean. It is critical for maximum adhesion of the Anti-Slip Tape that
the runway be dry, free of dirt, oils, and grease.
5. Measure and mark the runways with pencil guidelines to outline the tape installation area on the
ramp. Refer to the figure on the next page for a suggested layout of the Anti-Slip Tape.
IMPORTANT! Do not install this Tape directly on the edge of a Runway. Stay at
least 1 in. (25 mm) away from edges. Do not attempt to bend the
Tape over an edge.
6. Wash your hands. The Anti-Slip Tape’s adhesive side is protected by a paper or plastic film. You
will remove this film a few inches at a time to apply the Tape to the Runway.
IMPORTANT! Handle the tape by its edges. Minimize contact between the
adhesive and your hands. The oils from your hands will reduce the
adhesive’s long-term effectiveness.
IMPORTANT! BendPak recommends two people work together to install the Tape.
One person removes the backing and applies the Tape to the
Runway while the second holds the Tape in place over the
guidelines marked on the Runway.
7. Lay one piece of the Anti-Slip Tape on the runway and peel back about 2 inches (50 mm) of the
protective film. Apply the adhesive side to the Runway inside the guidelines you created in step 5.
8. Slowly remove the film as you press the exposed Tape’s adhesive side into the Runway. Work
slowly and apply 2 to 5 inches at a time to stay within your guidelines.
9. After applying the Tape use a heavy rubber roller to press the Tape onto the Runway and to
ensure firm contact with the adhesive.
10. Apply the Anti-Slip Tape to the remaining area of the Lift’s runways similar to the figure on the
next page.
HD-75BXT Series Four-Post Lifts 58P/N 5900282 — Rev. A — February 2023
Page 59
Caster Kit
The Caster Kit is an accessory option (purchased separately) and includes four assemblies, each of
which installs under one of the Lift’s four Posts. When the Lift is raised by the Caster Kit assemblies,
you can move it to the desired location.
Important: When the move is complete, remove the Caster Kit assemblies. Do not leave the
Caster Assemblies in place while operating the Lift.
HD-75BXT Series Four-Post Lifts 59P/N 5900282 — Rev. A — February 2023
Page 60
To move your Lift with the Caster Kit:
1. Raise the Lift to the first Safety Lock and engage it.
2. Locate the components of the four Caster Kit assemblies.
3. Using the supplied hardware, bolt the four Casters to the four holes in the four Caster Kit Shafts.
4. Take one Shaft and put the open end around the Post, with the Shaft on the inside of the Lift.
The Cradle of the Shaft needs to be directly below the Crosstube.
5. Put the Pin through the holes in the Caster Kit assembly and the Post.
6. Put the Cotter Pin into place on the end of the Pin.
7. Repeat Steps 4 through 6 for the other three Caster Kit Assemblies.
8. Lower the Lift down to the ground.
Make sure the Crosstubes are going into all four Cradles on all four Caster Kit Shafts; this is what
pushes the Bases of the Posts off the ground so that you can move it.
9. Move the Lift to the desired location.
10. Raise the Lift to a locking position and engage it there.
11. Take off all four Caster Kit assemblies.
HD-75BXT Series Four-Post Lifts 60P/N 5900282 — Rev. A — February 2023
Page 61
Red Lithium Grease
Red Lithium Grease
White Lithium Grease
inside all 4 Posts where
the Slide Blocks travel.
Approach
Side
Lubricate the Lift
All Cable Sheaves, Pins, and Boat Trailer Tongue Platform Ends, require occasional
lubrication
Use a small amount of White Lithium Grease or similar on the inside of the Lift Posts where the Slide
Blocks move. Repeat monthly or as required.
using a generous quantity of Red Lithium Grease. Repeat monthly or as required.
HD-75BXT Series Four-Post Lifts 61P/N 5900282 — Rev. A — February 2023
Page 62
Perform an Operational Test
BendPak strongly recommends doing an Operational Test of your Lift with a typical Vehicle before
starting normal service (a typical Vehicle is not required, but is recommended).
⚠ DANGERWhen you even hear the words “automotive lift,” your brain should automatically
remember that lifting a Vehicle is a serious endeavor with life-threatening risks.
Focus on what you are doing. Automotive Lifts are dangerous tools when used by
inexperienced or impaired operators.
safe this time because nothing happened last time
During the Operational Test, watch the Lift and its components and check for proper installation and
operation. If you run into an issue that does not go away, refer to Troubleshooting for more
information.
Note: Residual air in the Hydraulic System can cause the Lift to shake, move erratically, or
squeak when you start using it; this is normal. If it happens, do not worry; it will go away as
the Hydraulic System is self-bleeding. If it does not go away soon, try bleeding the Cylinder
of air. If it still does not go away, refer to Troubleshooting for additional information.
To test your Lift:
Do not assume you are going to be
.
1. Check the area around, above, and under the Lift for obstructions;
2. Drive the Vehicle onto the Lift. Try to center the Vehicle’s tires in the middle of each Runway.
3. Put the Vehicle into park, apply the parking brake, shift into gear (manual transmission).
4. Exit the vehicle and chock the wheels.
5. Press and hold the Up button; both Runways begin to rise.
6. After the Runways pass one or two Safety Locks (you will hear them as they pass), release the Up
button; the Runways stop rising.
7. Press
8. When the Runways get to the ground, release the Pushbutton and the Lowering Handle.
9. Wait for one minute.
and hold
Handle; the Runways start lowering.
the Pushbutton on the Pushbutton Air Valve, then press
⚠ CAUTION Always take a break between cycles. The Power Unit’s motor is
it cannot be run continuously.
10. Repeat the process, this time raising the Runways to a higher Safety Lock.
11. If the Lift is working without shaking, moving erratically, or squeaking, there is no need to repeat
the procedure.
move any obstructions
and hold
the Lowering
not
constant duty;
.
If the Lift is shaking, moving erratically, or squeaking (which is common during the start-up
period), repeat the procedure a couple more times, with at least a one-minute break between
cycles.
If you continue to have issues, refer to Troubleshooting for assistance.
HD-75BXT Series Four-Post Lifts 62P/N 5900282 — Rev. A — February 2023
Page 63
Review the Final Checklist
Make sure these things have been done
• Review the Installation Checklist to make sure all steps have been performed.
• Verify the Power Unit is getting power from the power source.
• Check the Hydraulic Fluid reservoir on the Power Unit; it must be full of approved Hydraulic Fluid or
automatic transmission fluid.
fluid.
• Check the Hydraulic System for leaks.
• Make sure all four Posts are properly anchored, shimmed, level, and stable.
• Make sure all Lifting Cables are properly seated in their Sheaves.
• Make sure all Safety Locks are operating normally.
• Make sure the backup Slack Safety Locks are
• If it has not been done already, perform an Operational Test of the Lift with a typical Vehicle. Refer
to Performing an Operational Test.
• Make sure a copy of the Installation and Operation Manual remains with the Lift.
You can damage the motor by running it without enough
before
putting the Lift into service:
not
engaged.
HD-75BXT Series Four-Post Lifts 63P/N 5900282 — Rev. A — February 2023
Page 64
Operation
This section describes how to operate your automotive Lift.
⚠ DANGERWhen you even hear the words “automotive lift,” your brain should automatically
Safety Considerations
⚠ WARNINGYour safety is dependent on reading, understanding, and implementing these
remember that lifting a Vehicle is a serious endeavor with life-threatening risks.
Focus on what you are doing. Automotive Lifts are dangerous tools when used by
inexperienced or impaired operators.
safe this time because nothing happened last time
Safety Rules.
Do not skip over them—read them carefully and follow
them; your life could literally depend on it!
Do not assume you are going to be
.
Do the following
• Check the Lift. Walk all the way around the Lift, checking for any missing, heavily worn, or
damaged parts. Use caution when driving a Vehicle onto wet or icy Drive-up Ramps or Runways;
not
do
take it out of service, then contact your dealer, emailsupport@bendpak.com, or call (800) 253-2363.
• Check the area. Keep the area around and under the Lift clean and free of obstructions;
anything that could cause a problem. Do not forget to check
obstruction, move it out of the way. If you find any other issues, resolve them before using the Lift.
Do not allow any people or animals within 30 feet of the Lift while it is moving.
• Check the operators. Make sure everyone who is going to operate the Lift has been trained in
its use, has read the labels on the unit, and has read the manual. Only the operator at the Controls
should be within 30 feet of the Lift while it is moving.
Do not allow children to operate the Lift. Do not allow anyone under the influence of drugs, alcohol,
or medication to operate the Lift. Do not allow any unauthorized personnel to operate the Lift.
Operators should wear non-skid, steel toe footwear and safety glasses when operating the Lift.
• Check for safety. Make sure everyone who is going to be walking near the Lift is aware of its
presence and takes appropriate safety measures. Only put Vehicles on the Runways.
When raising a Vehicle, do not leave it until it is engaged on Safety Locks. When lowering the Lift,
do not leave it until it is on the ground.
before
walk on Lift surfaces that are wet. Do not operate the Lift if you find any issues; instead,
you raise a Vehicle on your Lift every time:
above
the Lift. If you find an
• Check the Vehicle. Never exceed the Lift’s weight rating. Do not allow people inside a Vehicle
you are going to raise. Make sure the Vehicle is not overbalanced on either end or either side.
HD-75BXT Series Four-Post Lifts 64P/N 5900282 — Rev. A — February 2023
Page 65
Do
press and hold
Pushbutton.
Using the Controls
The Controls for the Lift include:
• Up button. Press and hold to raise the Runways. Located near the top of the Power Unit.
To put Runways onto a Safety Lock position
: Raise the Runways a little above where you
want them, then press and hold the Lowering Handle to lower the Runways onto the Safety Locks
(do not press and hold the pushbutton on the Pushbutton Air Valve). When the Runways stop
going down, they are engaged on a Safety Lock.
Before leaving the Lift, make sure all four corners are engaged on Safety Locks at the same height.
• Lowering Handle. Press and hold to lower the Runways. Located in the middle of the Power
Unit, the Lowering Handle is long and has a ball at the end.
To lower raised Runways down to the ground: press and hold
Pushbutton Air Valve first, then
press and hold
the Lowering Handle.
the pushbutton on the
Watch the Runways as they go down to make sure they are coming down evenly. If they are not,
stop lowering the Lift and troubleshoot the problem.
⚠ WARNINGOnly leave your Lift either engaged on Safety Locks or fully lowered.
• Pushbutton Air Valve. Press and hold as part of the process to lower the Runways. Located
on one side or the other of the Power Unit (depending on where it was installed). Pressing and
holding the pushbutton on the Pushbutton Air Valve disengages the Safety Locks, which is needed
to lower the Runways.
To raise Runways and
engage them on Safety
Locks:
1. Press and hold Up
Button.
To lower Runways:
1. Press and hold Up
Button for a couple of
seconds; this moves Lift
off Safety Locks.
2. When just past desired
height, release Up
Button.
3. Press and hold Lowering
Handle.
4. Runways stop going
down when engaged on
Safety Locks; release
Lowering Handle when
they stop.
not
5. Make sure all four Posts
are engaged at same
height.
2. Press and
Pushbutton.
3. Press and
Lowering Handle.
Runways begin lowering.
4. When Runways are fully
lowered (on ground),
release Pushbutton and
Lowering Handle.
hold
hold
HD-75BXT Series Four-Post Lifts 65P/N 5900282 — Rev. A — February 2023
Page 66
Raising and Lowering Vehicles
Keep the following in mind when operating your Lift:
• Be safe. Make sure to check for people, pets, and objects that might be in the path of the Lift as
you raise or lower it. If there is something in the way, stop the Lift and move it out of the way.
Watch the Lift carefully as it raises and lowers.
⚠ DANGERPay careful attention when you are raising or lowering your Lift. If a person or pet
gets stuck under the Lift, they could be injured or, in rare cases, killed. If a problem
arises, either stop the Lift or get it back to the ground, whichever is safest.
• The Power Disconnect Switch is there for a reason. We hope you never have to use it,
but if something unexpected happens, use the Power Disconnect Switch to immediately stop
the Lift from moving.
• Get what you need out of the Vehicle before lifting it. It is time consuming to raise a
Vehicle and then realize you left something inside.
animals in the Vehicle
• Make sure the Vehicle is balanced. If there is extra weight on one end or the other, remove
it or balance it before raising the Vehicle.
• Center the Vehicle’s wheels on the Runway. Centered wheels keep the Vehicle balanced.
To raise a Vehicle:
.
Never raise your Lift with people or
1. Make sure the Runways are on the ground. If they are not, move them down to the ground.
2. Drive a Vehicle onto the Runways.
Make sure all four wheels are fully on the Runways, as close to the center of the Runways as
possible.
Put the Vehicle into park and put on the parking brake. If it is a manual transmission, make sure it
is in a gear, not in neutral.
Chock the tires.
3. Press the Up button on the Power Unit.
The Runways begin to rise.
4. When the Runways get to the desired height, go up a little bit more, then release the Up button.
Press and hold the Lowering Handle.
The Runways Safety Locks will engage on the most recently passed Safety Lock.
If one of the four Safety Locks has not engaged, the non-engaged corner of the Lift will continue
to lower, while the others stay where they are. This results in a Runway that is not level.
Always
working under or near a raised vehicle.
verify that all four Safety Locks are engaged at the same height
before
⚠ WARNINGOnly leave your Lift engaged on Safety Locks or fully lowered.
5. With the Runways engaged on the Safety Locks, check around the Vehicle to make sure there are
no obstructions, and all ramps are resting on Safety Locks.
If you see anything wrong, fix it before anyone gets near the Runways or goes under them.
HD-75BXT Series Four-Post Lifts 66P/N 5900282 — Rev. A — February 2023
Page 67
To lower a Vehicle:
1. Verify there are no obstructions near or under the Runways you are about to lower.
If there are, move them out of the way before lowering the Runways.
2. Press and hold the Up Button for a couple of seconds.
This action moves the Lift off the Safety Locks on which the Runways rested.
3. Press and hold the Pushbutton on the Pushbutton Air Valve, then press and hold the Lowering
Handle.
The Runways will begin to lower.
4. When the Runways are fully lowered (on the ground), release the Pushbutton and the Lowering
Handle.
5. Remove the Tire Chocks.
6. Drive the Vehicle off the Runways when the way is clear.
HD-75BXT Series Four-Post Lifts 67P/N 5900282 — Rev. A — February 2023
Page 68
Maintenance
⚠ DANGER Before performing maintenance on your Lift, verify it is disconnected from power.
To maintain your Lift:
• Daily: Keep the Lift clean. Wipe up any spills, remove any dirt.
• Daily: Make a visual inspection of all moving parts and check for damage or excessive wear.
Replace any damaged or worn parts before using the Lift.
⚠ DANGER Do not use the Lift if the Lifting Cables are damaged or extremely worn. If a Vehicle
• Daily: Verify all Safety Locks are in good operating condition. Do not use your Lift if the Safety
Locks are damaged or excessively worn.
• Monthly: Check all labels on the Lift. Replace any that are illegible or missing.
• Monthly: Grease the lubrication points on the Lift. Use white lithium grease or similar on the inside
of the Lift Posts. Use Red Lithium Grease on the Sheave Pins and Bearings.
• Monthly: Check Hydraulic Fluid levels. Refill if low.
• Monthly: Lubricate the wire rope (Lifting Cables). Use a wire-rope lubricant such as 90-WT gear
oil or ALMASOL® Wire Rope Lubricant.
• Monthly: Check cable connections, bolts, and pins for proper mounting and torque.
• Every two months: Check all Anchor Bolts to verify they are properly torqued. If they are loose,
tighten them.
The Lift uses electrical energy; if your organization has Lockout/Tagout policies,
make sure to implement them before performing any maintenance. If you come into
contact with high voltage/current, you could be injured or killed.
is raised when you notice the damage or extreme wear, very carefully lower the
Vehicle to the ground. When the Lift is on the ground, take it out of service,
disconnect it from power, and make arrangements for repair or replacement.
⚠ WARNING:Do not operate your Lift if you find maintenance issues; instead, take the Lift out of
service, then contact your dealer, visit bendpak.com/support, email
support@bendpak.com, or call (800) 253-2363.
HD-75BXT Series Four-Post Lifts 68P/N 5900282 — Rev. A — February 2023
Page 69
Wire Rope Inspection and Maintenance
The Lifting Cables, are wire rope and should be inspected regularly:
• Wire rope should be replaced when there are visible signs of damage or extreme wear. Do not use
the Lift if it has damaged or worn Lifting Cables;
• Wire rope should be maintained in a well-lubricated condition at all times.
Wire rope is only fully protected when each wire strand is lubricated both internally and externally.
Excessive wear shortens the life of wire rope. Use a wire-rope lubricant that penetrates to the core
of the rope and provides long-term lubrication between each individual strand, such as 90-WT
gear oil or ALMASOL® Wire Rope Lubricant. To make sure the inner layers of the rope remain well
lubricated, lubrication should be done at least every three months during normal operation.
take it out of service
!
• All Sheaves and guide rollers that contact moving wire rope should be given regular visual checks
for surface wear and lubricated to make sure they run freely. This should be done every three
months during normal operation.
For all Sheave axles, use standard wheel bearing grease. For all Sheaves and/or guide rollers, use
90-WT gear oil or a similar heavy lubricant, applied by any method including pump/spray
dispensing, brush, hand, or swabbing.
• How often should you inspect?
Wire rope should be visually inspected at least once each day when in use, as suggested by
American Petroleum Institute’s Recommended Practice 54 guidelines. Any wire rope that meets
the criteria for removal must be immediately replaced.
• When should you replace wire rope due to broken wires?
Wire rope should be removed from service if you see six randomly distributed broken wires within
any one lay length (where a single strand makes a full turn around the rope) or three broken wires
in one strand within one lay length.
• Are there other reasons to replace your wire rope?
Yes. Corrosion that pits the wires and/or connectors, evidence of kinking, crushing, cutting, birdcaging, or a popped core, wear that exceeds 10% of a wire’s original diameter, or heat damage.
• How do you find broken wires?
a. Relax your rope to a stationary position and move the pick-up points off the Sheaves. Clean
the surface of the rope with a cloth — a wire brush, if necessary — so you can see any breaks.
b. Flex the rope to expose any broken wires hidden in the valleys between the strands.
c. Visually check for any broken wires. One way to check for crown breaks is to run a cloth along
the rope to check for possible snags.
d. With an awl, probe between wires and strands and raise any wires that appear loose.
HD-75BXT Series Four-Post Lifts 69P/N 5900282 — Rev. A — February 2023
Page 70
Troubleshooting
Note: If your Lift is not functioning correctly, you
must
remove it from service until it is repaired.
Unless stated otherwise, all maintenance may be performed by the owner/employer and does not
require trained lift service personnel.
⚠ WARNINGThe Lift uses electrical energy; if your organization has Lockout/Tagout policies,
make sure to implement them before performing any Troubleshooting.
Problem Corrective Action
Runways do not raise or do not lower,
once raised.
Runways do not lower past the nearest
Safety Lock when pressing and
holding the pushbutton.
Make sure there is sufficient Hydraulic Fluid in the reservoir.
Bleed air from the Hydraulic System.
Make sure the Hydraulic Hose is not pinched or leaking.
Make sure the Power Unit is getting power.
If the Hydraulic Fluid is dirty, replace it with clean fluid.
Make sure the Lift is not overloaded.
Contact Bendpak Support bendpak.com/support, email
support@bendpak.com, or call (800) 253-2363.
Problem with the Air Line; check to make sure all sections of the Air
Line are connected and not leaking or pinched.
One corner of the Lift is lower than the
other three corners.
Runways move erratically or squeak
when in use.
Runways do not stay up. Check for leaking Hydraulic Fluid.
Motor not running. Check the connection to the power source; make sure it is plugged in
Hydraulic Fluid is dirty. Replace the dirty fluid with clean, approved Hydraulic Fluid, such as
Runways make odd noises. Lubricate the bushings on the Sheaves on the sides of the
The Safety Lock on the lower corner is not engaged. Raise the
Runways up, then lower them down onto the Safety Locks. Check to
make sure all four Safety Locks are engaged.
Move the Runways up and down a few times to flush any residual air
from the Hydraulic System. Make sure to pause for at least two
minutes between cycles.
Make sure the Runways are engaged on their Safety Locks.
and of the appropriate voltage.
Make sure the wiring is correct; check the wiring diagram.
Dexron III, Dexron VI, Mercon V, Mercon LV, Shell Tellus S4 / S3 /
S2, or comparable.
Crosstubes using white lithium grease. If the Lift is new, a break-in
period may be needed; run the Lift several times each day. If the
noises persist, contact BendPak Support.
If you continue to have issues with your Lift, take it out of service, then contact your dealer, go to
bendpak.com/support, email support@bendpak.com, or call (800) 253-2363.
HD-75BXT Series Four-Post Lifts 70P/N 5900282 — Rev. A — February 2023
Page 71
Bleeding the Hydraulic System
The Hydraulic System on the Lift is self-bleeding, which means that in most cases any air in the system
can be removed by raising and lowering the Runways a few times; “bleeding” the Hydraulic System of
the unwanted air.
⚠ WARNING Before performing any maintenance on your Lift verify both Runways are on the
ground and the power source has been disconnected.
Symptoms of air in the Hydraulic System include Runways moving erratically and/or making odd
noises. These could be caused by other situations; refer to Troubleshooting for more information.
To bleed the Hydraulic System:
1. Raise and lower the Runways up to six times;
each cycle
The Lift’s motor cannot run continuously; it is designed for regular use, but not continuous use.
2. Watch the Runways as you raise and lower them.
When the Lift stops moving erratically or stops squeaking, you can stop the bleeding process.
3. Check the Hydraulic Fluid reservoir on the Power Unit.
Bleeding the Hydraulic System may significantly lower the amount of Hydraulic Fluid in the
reservoir.
4. Add additional Hydraulic Fluid if necessary.
If your Lift is still moving erratically or making odd noises after bleeding the Hydraulic System, refer to
Troubleshooting for more information.
.
pause for at least one minute between
HD-75BXT Series Four-Post Lifts 71P/N 5900282 — Rev. A — February 2023
Page 72
208 - 230VA C
Whi te
Wi re #5
Black
Wi re #9
Black
Wi re #3
Black
Wi re #7
Green
G
C
NO
SB
L2
L1
Wire Screw Connector
M
Wiring Diagrams
5585014
5585280
5585780
HD-75BXT Series Four-Post Lifts 72P/N 5900282 — Rev. A — February 2023
Page 73
Labels
HD-75BXT Series Four-Post Lifts 73P/N 5900282 — Rev. A — February 2023
Page 74
HD-75BXT Series Four-Post Lifts 74P/N 5900282 — Rev. A — February 2023
Page 75
HD-75BXT Series Four-Post Lifts 75P/N 5900282 — Rev. A — February 2023
Page 76
Parts Drawings
HD-75BXT Series Four-Post Lifts 76P/N 5900282 — Rev. A — February 2023
Page 77
HD-75BXT Series Four-Post Lifts 77P/N 5900282 — Rev. A — February 2023
Page 78
HD-75BXT Series Four-Post Lifts 78P/N 5900282 — Rev. A — February 2023
Page 79
HD-75BXT Series Four-Post Lifts 79P/N 5900282 — Rev. A — February 2023
Page 80
HD-75BXT Series Four-Post Lifts 80P/N 5900282 — Rev. A — February 2023
Page 81
HD-75BXT Series Four-Post Lifts 81P/N 5900282 — Rev. A — February 2023
Page 82
HD-75BXT Series Four-Post Lifts 82P/N 5900282 — Rev. A — February 2023
Page 83
Maintenance Log