Benchmark Scientific Incu-Shaker Mini Operation Manual

OM-BENCHMARK T205 (Ver. 2017.12.12)
Operations Manual
OM-BENCHMARK T205 (Ver. 2017.12.12)
Table of Contents
PAGE
Precaution for safety
3
1. General information and and precaution
3
1.1 Precaution related to power cable
3
1.2 Precaution for use
3
2 Feautures and specification
5
2.1 Features
5
2.2 Specification
5
3. OPERATION
6-14
Booting
6
Basic screen explanation
6
Temperature setting change
7
RPM setting change
7
Time setting change
7
Screen change order
8
Temperature calibration
8
Temperature setting(Advanced screen)
9
Temperature setting change
9
Time setting change
9
Alarm setting change
10
Shaker setting(Advanced screen)
10
RPM setting change
10
Time setting change
11
Alarm setting change
11
Temperature Step setting
12
Temperature, time setting
12
Shaker Step setting
13
RPM, Time setting
13
Step One Cycle Ending Screen
14
4. Warning message and fuse replacement
14-15
Fuse replacement
14
Event view
15
Door open event
15
Temperature and shaker event
15
Maintenance
15
Contact
15
OM-BENCHMARK T205 (Ver. 2017.12.12)
3
OM-BENCHMARK T205 (Ver. 2017.12.12)
1. General Information and Precautions
Safety Symbols:
1.1. Precautions related to the power cable
Always allow at least 3cm between the power cable and the back wall to prevent the back wall from causing pressure on the power cable.
Always use the electrical plug that was supplied with this instrument.
Never touch the power cord with wet hands. (This can result in electric shock.)
Never use a damaged power cord or power outlet.
In the event of smoke or a burning smell, immediately remove the power cord from the outlet.
1.2. Precaution for use
Do not attempt to disassemble this instrument. If service is required, please contact your local representative.
Never operate a flammable spray near this instrument. (This can result in a fire hazard.)
Always use caution when using flammable substances such as benzene, alcohol and LP gas. (Failure to do so can result in a fire hazard.)
Prevent foreign substances from contacting the door seal. (The inflow of outside air can negatively impact the temperature in chamber.)
Permissible ambient temperature range for transport: -10 to 60.
4
OM-BENCHMARK T205 (Ver. 2017.12.12)
ALWAYS ensure that the instrument is connected to an outlet with specifciations that match those of the serial number label.
(Over-voltage or under-voltage can damage the product and result in poor performance.)
When installing the instrument, always allow a distance of at least 30cm from the back wall. Install the unit in the way that the power plug is easily accessible and can be easily pulled in case of danger.
Install the instrument on a flat and stable surface, free from vibration and in a well-ventilated location. (If the surface is not level, it can cause an excessive vibration of the product.)
5
OM-BENCHMARK T205 (Ver. 2017.12.12)
2. Feature & Specification
2.1 Feature
Magnetic induction drive & Brush less DC motor provides less vibration and maintenance.
No interference with uniformity for cell culture by BLDC motor
User friendly, intuitive LCD touch panel
Moisture resistant structure by Epoxy – coated
Automatic stop function Once LID opens, shaker automatically stops for safety and convenience
Once-piece construction with acrylic cover
Transparent acrylic cover allows internal viewing without disturbance
Stable and Low Noise Shaking
Blushless DC motor and beltless drive system for shaker minimizes noise and vibration
Non-volatile memory for operation.
Easy - Platform Installation
Very simple way to place holder or spring rack platform on the shaker.
And Optional accessories available for most common laboratory vessels
2.2 Specification
1) Dimension (Exterior) : 28(W) X 47(D) X 33(H) cm
11.1(W) X 18.5(D) X13(H) in.
(Internal): 27.5(W) X 32.5(D) X 22.2(H) cm /
10.8(W) X 12.8(D) X 8.75(H) in. /
(Platform): 23.5(W) x 29.2(D) cm / 9.5(W) X 11.5(D) in.
2) Temperature range : Ambient +5 to 70
3) Temperature accuracy: ±0.2 at 37
4) Tempearature uniformity: ±0.5 at 37
5) Speed Range: 30~300 RPM
6) Shaking orbit: 19mm (3/4)
7) Circulation Fan: Convection Fan
8) Timer: Digital -1 min. to 47hr 59mm. (1 min. increments)
9) Motor: Beltless DC Magnetic Induction Drive
10) Weight: 25lbs/11.5kg
11) Electrical: 120V or 230V, 50~60Hz / 200W