Operation Manual
Analytical Balance
Series Tx
Models W3002A-120 / W3102A-220
(Touch Screen)
Revision 1-18
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com

INDEX
1 SAFETY INSTRUCTIONS AND WARNINGS ............................................................................ 3
2 STORAGE CONDITIONS ............................................................................................................... 3
3 PREPARING TO START UP THE DEVICE ............................................................................... 4
3.1 UNPACKING / PACKING ................................................................................................................. 4
3.2 OVERVIEW AND ACCESSORIES INSTALLATION .............................................................................. 7
3.3 INSTALLATION PLACE ................................................................................................................... 8
3.4 START-UP ...................................................................................................................................... 9
SIDE KEYBOARD OPERATION ........................................ ERROR! BOOKMARK NOT DEFINED.
3.5 DESCRIPTION....................................................................... ERROR! BOOKMARK NOT DEFINED.
4 SERIAL INTERFACE CONNECTIONS .................................................................................... 10
4.1 DISPLAY AREA OPERATION ......................................................................................................... 11
4.1.1 Operating instructions of the numeric and alphanumeric keypads for entering data ......... 13
5 STANDBY, LOGOUT, SWITCHING OFF FUNCTIONS ........................................................ 15
6 SIMPLE WEIGHING ..................................................................................................................... 16
7 CUSTOMIZED SETTINGS ........................................................................................................... 18
7.1 SELECTING THE LANGUAGE ........................................................................................................ 19
7.2 SETTING DATE AND TIME ............................................................................................................ 20
7.3 CREATING, CHANGING AND SELECTING THE USER PROFILE ........................................................ 21
7.3.1 Recovering and removing passwords.................................................................................... 26
7.4 PREFERENCES: LANGUAGE, DISPLAY APPEARANCE, BRIGHTNESS, BEEPER, FUNCTIONS ............ 27
7.5 SETTING THE WEIGHING PARAMETERS........................................................................................ 29
7.6 SELECTING THE UNIT OF MEASUREMENT .................................................................................... 30
7.7 SELECTING THE CUSTOM MEASUREMENT UNITS ......................................................................... 31
7.8 CALIBRATING AND SETTING THE CALIBRATION MODE ............................................................... 32
7.9 SETTING THE PERIPHERALS ......................................................................................................... 35
7.10 INFO ABOUT THE SOFTWARE ....................................................................................................... 39
7.11 SERVICE ...................................................................................................................................... 39
7.11.1 System data backup and restore ........................................................................................ 39
7.11.2 Factory reset ...................................................................................................................... 41
7.11.3 Software update ................................................................................................................. 42
7.11.4 Balance technical service .................................................................................................. 42
8 FUNCTIONS MENU ....................................................................................................................... 43
8.1 USING THE DATABASE ................................................................................................................ 44
8.2 FUNCTION FOR COUNTING THE PIECES ........................................................................................ 45
8.2.1 Pieces count screen with “Statistics” function. .................................................................... 47
8.2.2 Pieces count screen with “Check weight” function. ............................................................ 48
8.3 “CHECK WEIGHT” FUNCTION. ..................................................................................................... 49
8.3.1 “Check weight” screen function ........................................................................................... 50
8.4 “WEIGHT %” FUNCTION .............................................................................................................. 51
8.4.1 Screen of Weight % with “Statistics” function. .................................................................... 53
8.4.2 Screen of Weight % with “Check weight” function.............................................................. 54
8.5 FUNCTION TO “FIX THE DENSITY” .............................................................................................. 55
8.5.1 Screen with the “Density of a solid” calculation function. .................................................. 57
8.5.2 Screen with the “Density of a liquid” calculation function ................................................. 57
8.5.3 Screen with the “Density index” calculation function. ........................................................ 58

8.6 “STATISTICS” FUNCTION ............................................................................................................. 59
8.6.1 Screen with “Simple statistics” function............................................................................... 60
8.6.2 Screen with “Database statistics” function .......................................................................... 61
8.7 “TEXTILE” FUNCTION .................................................................................................................. 63
8.7.1 Screen of the “Textile” function. ........................................................................................... 64
8.7.2 Screen of the database textile function with statistics enabled ............................................ 65
8.8 “ANIMAL WEIGHTING” FUNCTION .............................................................................................. 67
8.8.1 Screen of the “Animal weighting” function. ......................................................................... 68
8.9 “MAXIMUM LOAD” FUNCTION .................................................................................................... 69
8.10 “RECIPE” FUNCTION .................................................................................................................... 70
8.10.1 Screen of the “Simple recipe” function. ........................................................................... 73
8.10.2 Screen of the “Database recipe” function. ....................................................................... 74
8.11 SETTING THE GLP DATA ............................................................................................................. 76
9 TECHNICAL FEATURES ............................................................................................................. 78
10 WARRANTY .................................................................................................................................... 79
11 DISPOSAL ........................................................................................................................................ 79

1 Safety instructions and warnings
CAUTION!
Please read these instructions for installation and operation carefully before
starting your work with the new balance. Keep this instruction manual for future
reference.
This balance complies with the directives and standards for electrical equipment,
electromagnetic compatibility and date safety requirements.
If the installation is not performed in accordance with the instructions given or is improperly
used, the warranty can be void.
▪ Do not use the device in areas at risk of explosion.
▪ Before starting the device for the first time, check if the power supply unit or
the power cord is damaged and confirm that the voltage of the wall outlet to
be used corresponds to the mains voltage required.
2 Storage conditions
▪ Storage temperature: +5 °C…+40°C
▪ Storage humidity: 45% - 75%.
▪ Keep the original balance packaging in case the instrument needs to be shipped for
servicing; disconnect all cables and any accessories to prevent unnecessary damage.
▪ Do not expose the balance to extreme temperatures and humidity unnecessarily, and
avoid violent shocks and vibration.

3 Preparing to start up the device
Below are all preparation steps to follow before initial use.
3.1 Unpacking / packing
- After opening the box from the top, you can find the accessory box containing: User's
Manual, Weigh Pan, Weigh Pan Support; Anti-draft ring, Power supply unit, Power supply
box. Remove the accessory box and then carefully lift the balance with the protective foam
parts in place.
▪ IMPORTANT: Keep the original balance packaging in case the instrument
needs to be shipped for servicing; disconnect all cables, remove weigh pan and pan
support, place rubber band around draft shield or tape the glass doors closed, and
separate and package accessories to prevent unnecessary damage.

Always use the original packaging for shipping the instrument to an
authorized Service Center to prevent damage. Below are the procedures.
- Before packing packing, remove the weight pan, pan support, draft ring, and any other
loose parts, and place them in the accessory box.
- Following the below steps to pack again the balance in its box:

3.3 Installation
▪ After removing the balance and accessories from the packaging, check for visible
damage to the device.
▪ Do not install the balance in any room or location where there are any air currents, strong
heat shifts, or vibrations.
▪ Do not use the balance in explosive atmospheres.
▪ The ambient humidity of the environment should be between 45% and 75%.

For internal calibration Analytical balance models, manually remove
the shipping screw at the bottom of the left-hand balance. Note: Semi
Micro (0.01mg readability) do not use this shipping screw.
Level the balance by adjusting the legs on the front of the balance. Some models also have
an adjustable leg on the rear left.
It is important to allow the balance to equilibrate to the ambient environment after
powering on, and before using. For 0.0001g balances, allow the balance to equilibrate
for 2 hours. For 0.01mg balances, allow the balance to equilibrate for 12 hours. For
calibration procedures, please refer to the "Device calibration chapter". Perform the device
calibration whenever it is moved to another place.
Never drop objects onto the the balance weigh pan, and never place objects on the pan that
weight more than the maximum capacity for the balance.
Any service must be performed by trained personnel and the spare parts used must be
original. To arrange service, contact your distributor or Accuris Instruments.
Insert the supplied power supply unit jack into the connector on the back
of the balance.
Then connect the power adapter to an appropriate power outlet near the
device. Do not use cables/extensions that do not comply with applicable
regulations.

Powering On
The power button is located on the front control panel to the left of the touch screen.
After connecting the power supply unit, the device will start automatically without having to
press the power button.
Use the power button to turn off the device and restart the system when the power cord is
already plugged in.
The turn-on and shut-down time of the device takes about 20 seconds, during this time
the display will be turned off.
When powering on, wait for the initial screen to appear before performing any other
operations.
When switching off, wait for the green LED to turn off before removing the power
supply socket, if necessary.
4 Serial interface connections
The device is equipped with an RS 232C interface for connection to a serial printer.
To ensure communication between the device and a printer, the following conditions must
be met:
Connect the printer using a suitable cable matching the position of the printer signals with
the device ones.
Set the transmission speed and type of printer correctly according to the parameters of the
printer. See Chapter 7.7
It is recommended that you use the Accuris Balance printer W3130 (DPP-250) from
Benchmark Scientific. (If you are using different printers, not all printing capabilities will be
available).

4.1 Touch Screen Operation
The balance incorporates a color touch screen display that lets you touch the screen in active
areas to quickly access the various menus and features of the device.
Measuring unit indication, by tapping the symbol, you can access the
measurement unit menu and select the desired unit.
Indication of weight displayed.Net net value, Ldr gross value
Analog indicator bar of magnitude being measured.
Technical Specifications for the instrument

2 Menu Bar displaying the date, time, for user selection, access to weighing functions,
weighing and device shutdown parameters setting.
Tap this area to access the menu for available functions.
Tap this area to access the menus for weigh settings, display preferences,
peripheral units setup, and users customization.
Tap this area to access the switching on or off menu for the device
standby mode.
Tap this area to access the user menu.
3 Function key menu bar.
Touching the keys displayed in this area, you will run the corresponding function. Below
are all the keys available in the simple weighing screen. The function key display bar
varies according to the selected applications.
Key bars available in simple weighing
screens.
Print: Data printing activation key.
- 0-: Reset activation key.
-T-: Tare operation activation key.
Gro/Net: Net or gross weight display mode
key.
T Man: Key for entering a tare value
manually.

4.1.1 Operating instructions of the numeric and alphanumeric keypads for entering
data
The operation of the alphanumeric keyboard described below is valid for all data entry
operations in the various operating modes of the device.
Mod 1
Mode 2
Mod 3
Alphanumeric keypad.
Selection key for entering uppercase or
lower case letters
Delete key of the last entered character
Delete key for all entered characters
Back and forward cursor movement key on
the inserted string
Key to confirm and store the entry
Keyboard character selection key. Tap this
key to rotate the various characters
available for entry:
Mod 1, Mod 2, Mod 3
Input operation cancellation key.

5 Standby, logout, switching off functions
After inserting the power cord into the mains socket, the device will automatically turn on
showing the basic weighing screen.
Tap the area with the symbol
to access the switching off menu.
There are 3 switching off modes:
▪ Display off.
▪ Logout.
▪ Switching off.
Display off
By selecting the display off mode, the
device will enter in the standby mode, the
display will be off and it will remain ON only
the lower-right command to turn on the
system again.
Touch the symbol to return to the basic
weighing screen.
Logout
Select the logout mode to enable the user
used.
Touch the key “Start” to enable again the
user and, if the user is password-protected,
you will be required to enter it.
Touching the key , you can select
another user and start the device again.
Switching off
By selecting the power-off command, the
device will be off. To restart, you will need
to press the button on the left of the device
or remove the power plug and reinsert it.

6 Simple weighing
After connecting the power, the green status LED on the left side of the device will light up.
This phase will last about 20 seconds, and the display will remain off all the time. After the
data loading phase, a screen will show the capacity and resolution of the balance. Then the
device will be placed in the simple weighing screen.
At first power on, the device starts by activating the default user with the factory settings.
In the weighing screen, the area displaying the
weight shows the value of the weight on the
weighting plate.
Use the -0- key to set a new zero point and reset
all tare values.
If you work with weighing boxes, first zero the
balance. Place the container and press the “-T-
”key.
Or use the T Man key to enter a known tare value
manually.
The Net symbol on the display indicates the net
weight. Press “Net” to see the gross weight
“Lrd”.
“T= “ indicates the tare value captured.

Place the material to weight on the balance and
wait for the stability symbol to light up before
detecting the value.
Press “Lrd” and “Net” to display the gross and net
weights and vice versa.
To reset the balance, remove all items from the
plate and press the “- 0 -“ key.
If you entered a manual tare, press “ T-Man” and
“C” key to clear the tare value.

7 Customized settings
This section explains all the customization features of the device. Each function described
below will allow you to set it differently for each user.
N.B. Some settings can only be modified by users with administrator permissions.
▪ Calibration menu
▪ Setup
▪ Users setup
▪ Preferences
▪ Info
▪ Service
To access the settings menu, tap the button in the top bar of the display.
The following screens will be displayed with all the functions of the setup menu.
Indicator of the number of pages
available.
To scroll through the next and back
pages, tap on the arrows.
Return to the
previous screen
Function indicator not available or not enabled for users
without administrator rights.

7.1 Selecting the language
In the settings menu, select the "Preferences" function.
Tap “Language” in the menu list.
You can select the device's use language.
Then select the desired language.
Automatically, all screens will be translated into
the selected language.
N.B. The selected language will only be
assigned to the user with whom the selection
was made.

7.2 Setting date and time
Select “Setup” in the setup menu.
Enter the new date and time values. You can also select the 24-hour or 12-hour format for the
hour.
N.B. The date and time setting is not customizable for each user, but once defined it will be
changed for all users.
Tap “Date and time” in the menu list.
Tap “Date” in the menu list to change the
date.
Tap “Time” in the menu list to change the
time
Tap “24h – 12h” in the menu list to set the
time format.
A numeric keypad will be displayed for
entering the date and time in
"“dd/mm/yyyy” mode for the date and
“hh:mm:ss” for the time
Tap “OK” to confirm the new settings, “C”
to delete all entered data or tap “X” to exit
without changing the value.

7.3 Creating, changing and selecting the user profile
The balance can be customized for multiple users. You can create up to 10 different usage
profiles. At the first turn on, the “Default” user is enabled and this user cannot be either
deleted or renamed.
Each user can then fully customize all the included database device settings. Once you've
created your profile, just touch "User Area" on the Home screen and select the user you want.
All settings for the selected user will then be loaded. From this moment on, any changes
made to the enabled user will be stored and made available each time the user is selected.
You can create two types of user:
▪ Administrator
▪ Standard
Creating an administrator user allows the user to access all the device setting features and
changing or deleting other users.
Creating a standard user allows the user to access only some of the device setting features.
The prohibition display that appears when you touch a feature that is not available for the
standard user is as follows:
You must log on with an administrator user to change the protected functions.
Also, after you have created an administrator and standard user, you will be able to assign an
access password that will be required each time you select the user and turn on the device.
Below are all operations related to the user modification and deletion.
In the settings menu, select the "Setup Users"
This screen allows you entering the
following functions:
▪ New user
▪ Edit user
▪ Rename user
▪ Copy users
▪ Delete user
▪ User Password

▪ New user
By selecting the "New User" function, you
can define a new user. The maximum
number of users that can be entered is 10.
You will be prompted to select whether the
user you want to create must have
administrator powers or be a standard user.
The keyboard for entering the username
will then be automatically activated.
The maximum number of characters
allowed is 30.
The insertion method distinguishes
between uppercase and lowercase letters,
so a user entered as "TEST" will be
different from a user entered as a "test".
After searching for a new user, go back to
the main screen.
Tap the user selection area and select the
user you have just created.
From now on, all changes to the functions,
databases, or analytics results will be
associated with the user, and each time
they are called, they will be automatically
reloaded.
The left-hand symbol of the username
indicates the type of user:
Administrator
Standard

▪ Edit user
In the "Edit user " menu, you can change
the user type ("Standard or Administrator")
and temporarily unlock the standard user
locked settings.
Type
If the user is of the standard type in order to
modify the user type, a user's password
with administrator rights will be required.
Select “Standard” to set the user in
standard mode or select “Administrator”
to set the user with administrator rights.
Settings
Selecting this function will prompt you to
enter a user's password with administrator
rights.
Then select the "Enable" function to
temporarily unlock the standard user or
select the "Disable" function to lock the
user again.
After you unlock the user in the base
screen on the left side of the username, an
open padlock will appear.
Unlocking will remain active until it is locked
again through the user editing menu, or
when another user is selected or the device
is turned off.

▪ Rename users
By selecting the "Rename Users" function,
you can change the name of the selected
user.
Select the user you want to rename.
The name change keyboard will be
displayed.
Tap " X " to cancel the operation or change
the name and confirm with the "Enter" key.
▪ Copy users
By selecting the "Copy Users" function, you
can create a new user with the same
configuration as an existing user.
Any databases will not be copied and no
password protection will be enabled. To
copy the databases of another user, you
need to export and import them to the
desired user.
Select the user you want to duplicate.
Enter the name to assign to the new user
and confirm with the "Enter" key.
▪ Delete users
By selecting the "Delete Users" function,
you can permanently delete a user and its
databases.
The list of stored users will be displayed,
then select the user to delete.

Confirm by tapping the "Yes" key or cancel
the operation by tapping the "No" key.
▪ User password
By selecting the "User Password" function,
you will be able to assign a "Standard" or
"Administrator" user password.
You will then be asked to re-enter the
password for confirmation.
Enter it and tap the "OK" key.
From this moment on, every time you want
to access the user, you will be required to
enter your password.
N.B. Write down your password and
store it in a safe place.
Warning! In case of loss, you will only
be able to recover the password for the
"Standard" user. The recovery
procedure is described in chapter 8.3.1.

7.3.1 Recovering and removing passwords
User password protection is applicable to both "Standard" and "Administrator" users. In the
first case, if the user forgets its password, you can update it from the "User Password" menu.
After selecting "User Password", you will be
asked to enter the "Old Password".
Enter an administrator password.
After selecting "User Password" you will be
asked to enter the "Old Password".
Enter an administrator password.
Then enter the "New password" to assign
to the user.
Confirm the password you have just
entered.
From now on, the "Standard" user will have
a new login password.
N.B.
To remove the password, upon the
request for entering the new password
and confirmation of the new password,
tap the "OK" key without typing any
value.
CAUTION! If the lost password is that of an administrator, you will need to contact a
Service Center to retrieve it.

7.4 Preferences: language, display appearance, brightness, beeper,
functions
For each user, you can set a graphic display, the language of use, the activation tone of the
beeper and the brightness of the display. Below are the various options available and their
activation mode.
In the settings menu, select the "Preferences" function.
The parameters that can be set in the
"Preferences" menu are as follows:
▪ Language (see chapter 7.1)
▪ Appearance
▪ Brightness
▪ Beeper
▪ Functions
Appearance
You can choose between 6 different color
combinations and select the desired one by
tapping the corresponding key
Brightness
There are 4 levels of brightness on the display.
Select the desired one by tapping the
corresponding key.
Beeper
The beeper function enables you to activate or
deactivate the beeper. When activated whenever
you touch the active parts of the touch screen, a
beep is released.

Functions
You can decide which functions to make
available and with which sequence to display
them for each individual user.
The function display sequence in the relevant
screen corresponds to the sequence assigned to
function keys F1 to F10
To assign a function, press the key you want to
assign and select one from the list of available
functions.
To remove a function, press the key
corresponding to the function you want to remove
and select "None" in the list.
From the base weighing screen, tap to
access the functions menu.
To switch to the next or previous screen tap the
keys:
Next
Back

7.5 Setting the weighing parameters
For proper use of the balance, it is important to make the correct weighing parameter settings
according to the operating environment.
This section describes the filter parameters, stability, autozero and weighing units.
In the settings menu, select the "Setup" function and then the "Weighing parameters"
function.
In the "Weighing parameters" screen, the set
values (in the box to the right of the parameter)
are immediately verifiable.
By touching the parameter key you want to
change, you can change the value.
▪ Filter: the filter function allows to speed or
slow down the balance response according to
weighing requirements and environmental
conditions. By selecting Level1, the response
will be immediate, but the balance will remain
more sensitive to environmental disturbances
such as ventilation and vibration. By
increasing the level, the response will be
slower and the indication more stable.
➢ Level 1: dosage conditions
➢ Level 2: stable conditions
➢ Level 3: unstable conditions
▪ Stability: this function allows you to adjust the
balance to the working environment. When
using the device in a vibration-free
environment, select level 0. The default level
is 2. Use level 3 for very disturbed
environments.
➢ Level 0: For stable environments.
➢ Level 1: For poorly stable
environments.
➢ Level 2: For unstable environments.
➢ Level 3: For heavily unstable
environments.

▪ Autozero: automatic zero correction
constantly adjusts the zero value. These
variations may be due, for example, to dirt that
can be deposited on the plate. You can
disable this function by selecting "Off" mode.
Level 1 is the one with minor correction until it
reaches level 3E which is the maximum
correction.
7.6 Selecting the unit of measurement
Weighing operations can be performed with different units of measurement. Below is shown
how to select the desired weighing unit.
In the settings menu, select the "Setup" function and then the "Units selection" function.
On the "Units Selection" screen, all available
weighing units are immediately displayed. Tap
the desired unit to select it and enable it.
The last three units of measure, K1, K2, K3, are
customizable units. For reference, refer to the
chapter "Selecting the custom measurement
unit".
N.B.: The measurement unit selection can
also be made directly from the weighing
screen; by tapping the symbol of the current
unit displayed, you will have access directly
to the list of available units.

7.7 Selecting the custom measurement units
You can define up to three custom units per user. This allows you to perform calculations
directly from weighing detection (i.e. volume, paper grammage g/m3). The custom weight unit
can be recalled in all fields and menus where the units can be selected.
In the setup menu, select the "Setup" function and then the "Custom units setup".
On the “Custom units setup” screen, you can
select one of the three units K1, K2, K3 available
to personalize it.
After the selection, enter the following data:
▪ Name: enter the unit identifier (max 15
characters).
▪ Symbol: enter the symbol you want to assign
to the unit of measurement (max. 3
characters). The weight units g, kg, lb and so
on. are not allowed
▪ Multiplier factor: enter the multiplicative
factor with which the weighing result has to be
calculated
▪ Decimal point position: enter the position of
the decimal point with which you want to
display the result (i.e. entering 1, the value
123,123 will be displayed as follows: 12312,3)

7.8 Calibrating and setting the calibration mode
Electronic balance performs mass measurements using gravity (g). Differences in geographic
regions and altitude vary the gravity acceleration (g).
Therefore, in order to obtain accurate measurements, the balance must be adapted to the
place of use and environmental conditions. This adjustment is performed by the calibration
function.
Select the "Calibration menu" function in the settings menu.
In the calibration menu, you can calibrate, display
and print the data for the last calibration and set
the calibration mode.
Before performing the calibration procedure,
check that the plate is empty.
▪ Calibration: By tapping the calibration key,
the calibration procedure corresponding to the
set calibration mode will be activated.
Load the required calibration weight or tap the
"Abort" button to cancel the calibration
procedure.
Wait for weight capture.
If the operation is successful, the weighing
screen will display with the calibrated weight
value.
Remove the weight from the plate.

▪ Calibration date: in the calibration data
screen, you can check the date when the last
calibration was performed, the mode with
which it was performed, the weight value
used, and the correction made with respect to
the previous calibration. By tapping the "Print"
button, you can print the displayed data.
▪ Calibration mode: the balance can be set to
calibrate with two different modes:
External default
By selecting the default calibration mode when
the calibration command is given, the required
weight will be the factory default setting, the value
of which will vary depending on the balance
model.
External custom
By selecting the external custom" calibration
mode, you can set a custom calibration weight
value.
After selecting the "mode of choice", tap the
Weight Setting button to set the desired weight
value.

Internal*
By selecting the internal calibration mode when
the calibration command is given, the balance is
automatically calibrated through the motorized
auto-calibration internal system.
Automatic*
By selecting the automatic calibration mode, the
balance automatically calibrates when the
ambient conditions change or within a set time of
60 to 999 minutes. Also with this mode, you can
calibrate each time you want by tapping the
"Calibration" key.
To change the auto-calibration range, tap the
"Calibration Range" key and set the desired
range between 60 and 999 minutes.
* The internal and automatic calibration mode
is only available for auto-calibration models.

7.9 Setting the peripherals
This section describes the features and settings of the RS232 and USB serial outputs that the
device is equipped with.
In the setup menu, select the "Setup" function and then the "Peripherals" functions.
In the "Peripherals" menu screen, you can
immediately check the values of the parameters
set (in the box on the right of the parameter).
Tapping the parameter key to be set will activate
its screen with the list of the various selectable
options.
▪ Printer: this function allows you to select the
device connected to the serial output.
➢ Dpp250: command print, by touching the
"Print" button for the Dpp250 printer.
➢ Dpp350: command print, by touching the
"Print" button for the Dpp250 printer.
➢ Tlp50: command print, by touching the
"Print" button for the Tlp50 printer.
➢ Generic: command print, by touching the
"Print" button for generic serial type printer.

-------------------------------
Liquid density:
1.0 g/cm3
Air P.: 200.04 g
Liq. P.: 100.02 g
Result (Solid Dens.):
2.0000 g/cm3
-------------------------------
➢ File on Usb-Key: command print, touching
the "Print" button will print to file. In order to
use this mode, you will need a USB stick to
save the files. (You can use a dedicated
USB stick for that purpose only).
With the "File on Usb_Key enabled" mode
before executing the print command, verify
that the save USB stick is inserted in the
USB port on the left side of the device.
While saving the file on the screen, you can
scroll through the information that will be
saved in the file.
At the end of the save, the name of the file
assigned automatically will appear on the
screen.
The USB stick will then contain a
compressed file with a text file (.txt) showing
the weighing data or the result of the
function used.
Example of printing with density function.

▪ Baud Rate: serial transmission speed
selection parameter.
Selectable speeds are as follows:
➢ 1200 Baud.
➢ 2400 Baud.
➢ 4800 Baud.
➢ 9600 Baud.
➢ 19200 Baud.
➢ 38400 Baud.
▪ Stability: check of the stability before data is
transmitted. It is possible to decide whether to
enable or disable stability control before
printing the weight value:
➢ On. Check enabled.
➢ Off. Check disabled.
▪ Print heading: this function allows you to
place a header at the beginning of the receipt.
The function can be:
➢ On. Bill heading enabled.
➢ Off. Bill heading disabled.
➢ Print heading Setup: Activation of the
screen for inserting the desired text for the
receipt header.
In the print header screen, tap the rectangles that
indicate the line number to automatically enable
the alphanumeric keypad and enter the desired
text with a maximum number of 40 characters per
line.
Tap the "Ok" key to confirm the entered text.
NB. You can enable and disable the bill header
function without losing the inserted text, which will
remain stored until the contents of the various
lines are deleted.

▪ Paper progress: this function allows you to
set a blank number of lines to add at the end
of the bill to allow the printer to exit from it.
The input numeric keypad will automatically
turn on, so enter the desired number of lines
(between 0 and 9) and tap the "Ok" key to
confirm the entered number.
▪ G.l.p.: this function allows you to enable or
disable the g.l.p. data printing after user have
entered it
➢ On. g.l.p. data print enabled.
➢ Off. g.l.p. data print disabled.
For information entry and G.l.p. database
management, see chapter 9.9
▪ Time and date: this function enables you to
enable or disable the time and date printing.
➢ On. Calibration data print enabled.
➢ Off. Calibration data print disabled.
Time and date printing cannot be deactivated
with the G.l.p. function enabled.
▪ Balance cal. data: this function enables you
to enable or disable the calibration data
printing of the balance.
➢ On. Calibration data print enabled.
➢ Off. Calibration data print disabled.

7.10 Info about the software
This section explains how to view information about the software versions of the tool.
In the settings menu, select the "Setup" function then the "Info" one.
The information on the Info screen will be
requested by the technical staff in case of
assistance request.
7.11 Service
This section describes all the functions related to the Service and Backups of the device data.
In the settings menu, select the "Setup" function then the "Service" one.
The functions available in the Service
menu are as follows:
▪ System data backup and restore
▪ Factory reset
▪ Software update
▪ Balance technical service
7.11.1 System data backup and restore
You can back up the system completely or restore data and configuration previously saved on
a USB stick.
This section describes the steps to be taken to export or import the data.
N.B. It is recommended to use an empty USB stick that is dedicated to data save and
recovery operations.

▪ System backup: this command allows
you to save all users and their
configurations stored in the system,
including its drying database and
saved test results.
You must have a USB stick to back up.
Insert the stick into the USB port on the left
side of the device, and press the "OK" key.
Tap the "Abort" button to cancel the backup
operation.
If the USB stick is inserted successfully,
after confirmation, the alphanumeric
keypad will automatically be displayed for
entering the name that you want to assign
to backup.
A screen with the message "Completed!"
will report that the export operation was
successful.
A backup folder with the assigned name
was then created in the USD stick.
Opening the folder, you will find a set of
files and subfolders that contain all the
data.
N.B: Do not modify or rename any files to
avoid damaging the content. The folder will
be automatically restored to the device by
using the System Restore command.
This folder will be automatically restored to
the device by using the System Restore
command.
▪ System restore: this command allows
you to restore all users and their
system configurations previously
exported with the backup command on
a USB stick.
N.B. You can import the exported data
from another device, so you can
configure multiple device s with the
same users and the same settings.

Insert the USB stick into the USB port on
the left side of the device, and press the
"OK" key.
Tap the "Abort" button to cancel the system
restore operation.
If the USB stick is inserted correctly, after
confirmation, the alphanumeric keypad will
automatically be displayed for entering the
name of the backup you want to restore.
A screen with the message "Completed!"
will report that the system recovery
operation was successful.
7.11.2 Factory reset
You can perform a total reset of the device to bring it back to the initial conditions.
Tap the "Factory Reset" button, confirm by touching the "Yes" button, or cancel the operation
by tapping the "No" button.
N.B. Be careful as all the data of all users including their databases will be lost. If you
want to save them, make a backup before the factory reset.

7.11.3 Software update
You can make any software updates provided by the manufacturer via the USB port.
Below are the steps to be taken to upgrade.
Selecting the "Software Update" function
will display the screen with the confirmation
request.
Select "No" to cancel the operation, or
"Yes" to continue.
Insert the USB stick into the port on the left
side of the device by checking before the
stick is loaded with the upgrade program
supplied by the manufacturer and confirm
with the "Ok" key.
If the selected file is correct, the upgrade
operation will be enabled and a displayed
counter will indicate the progress status.
N.B. Once the software upgrade
operation has begun, do not power off
the device until the operation
completes.
During the upgrade, the device will turn
off and restart automatically; do not
press any key, but wait for the operation
finished successfully indication.
7.11.4 Balance technical service
The technical service function of the balance can be accessed by password only to the
authorized technical personnel.

8 Functions menu
This section describes all the functions available for weighing. All of the features described
below are customizable in their databases for each user; they can be enabled, disabled, and
sequenced according to its usage needs. (See section on preferences in the functions
section.)
So each time you change the user, its function settings will vary.
Tap the button , to access the functions menu.
Use the keys , to scroll through the displayed back and next pages.
Tap the icon corresponding to the function, you want to access the relevant settings.
To exit the functions menu, tap the button or .

8.1 Using the database
All functions can be customized for each user by storing the desired modes and items through
the relevant database.
The following are the search, save, delete, and editing functions for all databases. For
entering data in the database, refer to the paragraph corresponding to the desired function.
After selecting the desired function, tap the "Database" key to access the database menu for
the desired function.
▪ Every time a new user is created, the
database will be completely empty.
The following describes all the
functions available to all databases:
▪ Selection by name: by tapping this
key you can call up a program by
entering the corresponding name.
▪ Selection list: by tapping this button
you can call up a program by selecting
it from a list.
▪ New: insert new record (refer to the
paragraph corresponding to the
desired function).
▪ Edit: by tapping this button, you can
access the editable parameters of the
function.
▪ Delete: tap this button to delete one or
more previously stored records.
▪ Print: by tapping this button, you can
select a record and print it.
▪ Export (Usb): by tapping this button
you can export the database to the
USB stick.
▪ Import (Usb): by tapping this key, you
can import a previously predefined
database from a USB stick.
Use the keyboard to enter the name to
assign to the new record.
The maximum number of characters that
can be entered is 30.
Tap the "Enter" key to confirm.

8.2 Function for counting the pieces
The pieces counting function allows you to count the pieces through sampling with a certain
number of pieces or entry of the value of the average weight of the pieces to be counted.
To access the function from the "Functions" menu, tap the "Piece count" icon.
Parameters entry:
Mode:
By tapping this key, you can select the
count mode:
▪ Weigh samples.
Counting by sampling a certain number of
pieces. Enter the number of samples you
want to use for the count by tapping the
"Number of samples" key.
▪ Unit mean weight.
Count by entering the weight value of the
single piece to be counted. Enter the
weight value by tapping the button "Unit
mean weight"
Start:
After selecting the count mode, tap the
"Start" button to perform the count of the
pieces.
Carry out the container tare if necessary, in
the case of sample counting before
counting, it will be required to load the
number of pieces chosen (for sampling) on
the plate, while in the mode with average
unit weight, you can go directly to the count
of the pieces.

Database:
By tapping the "Database" key, you can
create a custom counting database of
different items with different methodologies.
Using the database in addition to the count
of the pieces, you can perform statistical
count control and use up to two threshold
levels for packing control.
Tap the "New" key and enter the name of
the new record to be stored.
▪ Description: enter a description of the
item.
▪ Mode: select the count mode.
▪ Samples number/ Unit mean weight:
enter the number of samples or the
average unit weight of the pieces.
▪ Options: you can select the statistical
control by activating the "Statistics"
function or by controlling the pieces by
activating the "Control of value"
function.
Statistics:
▪ To enable this function, you need to
include:
▪ Nominal value: enter the nominal
value of the number of pieces to be
controlled.
▪ T2+, T2-, T1+, T1-: enter the error
tolerance threshold values. (Optional
entry).
▪ Save: tap the "Save" button to store
the recorded record.

Check weight:
▪ To enable this function, you need to
enter:
▪ Lower limit: enter the minimum
number of acceptable pieces.
▪ Upper limit: enter the maximum
acceptable number of pieces.
▪ Sound: you can activate or deactivate
the beep function when the number of
pieces is within the set range.
▪ Save: tap the "Save" button to store
the recorded record
8.2.1 Pieces count screen with “Statistics” function.
The following describes the pieces counting functions with statistical calculation.
Tap the "Ok" key to capture a new weight and tap the "End" key to end the capture and
perform the final statistical calculation.
Parameters used for
counting
Last weighting
delete key.

8.3 “Check weight” function.
This function allows you to define three different weight check methods:
▪ Weight check with upper level threshold
▪ Weight control with lower level threshold
▪ Weight control within the two thresholds.
To access the function from the "Functions" menu, tap the "Simple" icon.
To activate the function, enter the values for
the "lower limit" or "upper limit" or both,
according to the method you want.
Lower Limit, Upper Limit:
In the Limit Input screen, you can select the
unit of measurement to be used for testing by
tapping the "Unit" key.
To deactivate the limit, enter the value "0" or
tap the "C" key and then tap the "OK" key.
Beeper: enable or disable the beeper. In case
of enabling when the weight value is within the
set range, a beep is release.
Start:
After entering the required data, tap the "Start"
button to activate the weight check function.
Database:
By tapping the "database" button, you can
create a custom weight check database with
different items and methods.
Tap the "New" key and enter the name of the
new record to be stored.
Enter the required data:
▪ Description: enter a description of the
item.
▪ Lower limit
▪ Upper limit
▪ Sound
Then tap the "Save" button to save the record.

8.4 “Weight %” function
This function allows you to determine the weight percentage of a sample based on a
reference weight.
The value of the reference weight can be obtained by a sample weight or manually entering
the weight value.
To access the function from the "Functions" menu, tap the "Weight %" icon.
Select the mode:
Automatic reference:
Selecting this mode upon startup will
require you to load the reference sample
weight (100%) on the weighing plate.
Manual reference:
Selecting this mode requires you entering
the reference weight value (100%). Then
tap the "Reference Weight" key and enter
the weight value in the input screen and
select the desired unit of measurement.
Start:
after selecting the desired mode and
entering the required data, tap the "Start"
button to run the "Weight%" function.
Database:
by tapping the "Database" button, you can
create a custom database to perform
weighing in percent with different
methodologies.
Using the database in addition to the
simple percentage weighing, you can
perform statistical weighing checks or set
up to two levels of weight check thresholds.
Tap the "New" key and enter the name of
the new record to be stored.
▪ Description: enter a description of the
item.
▪ Mode: select the weight reference
mode.

▪ Reference weight: enter the reference
weight value in manual weight mode.
▪ Options: you can select the statistical
control by activating the "Statistics"
function or the weight check by
activating the "Value check" function.
Statistics:
To enable this function, you need to enter:
▪ Nominal value: Enter the nominal
weight value to be checked.
▪ T2+, T2-, T1+, T1-: enter the error
tolerance threshold values. (Optional
entry).
▪ Save: tap the "Save" button to store
the recorded record
Check weight:
To enable this function, you need to enter:
▪ Lower limit: enter the minimum
acceptable weight value.
▪ Upper limit: enter the maximum
acceptable weight value.
▪ Sound: you can activate or deactivate
the beeper function when the weight is
within the set range.
▪ Save: tap the "Save" button to store
the recorded record

8.4.2 Screen of Weight % with “Check weight” function.
The following are the functions of the weight% with weight check.
By tapping the "i" key, you can see the parameters used for weight check.
The weight check bar is yellow when the loaded weight is lower than the minimum threshold,
green when the weight is within the set range (with the beep indication when activated) and
red when the weight is greater than the upper threshold set.

8.5 Function to “Fix the density”
The density function allows to determine the density value of solid or liquid substances. The
determination is based on the principle of Archimedes that a body immersed in a liquid
receives an upward thrust equal to the weight of the volume of the displaced fluid. For the
determination, you can use the lower weighing device (if present in the scale or the
"hydrostatic weighing kit" to place on the weighing plate (optional).
To access the function from the "Functions" menu, tap the "Density" icon.
Select the mode:
Liquid density: selecting this type of
measure, you will be required to enter the
solid density value (g/cm3) to be used to
determine the density of the liquid.
Then tap the "Start" button to proceed with
the measurement
Solid density: selecting this type of
measure, you will be required to enter the
solid density value (g/cm3). If using distilled
water or ethanol, select the relevant item
below and enter only the liquid temperature
value. The density of the selected liquid at
the temperature entered will automatically
be entered. (The reference tables are
stored inside the device).
Then tap the "Start" button to proceed with
the measurement
Density index: by selecting this type of
measurement, you can determine the
difference in density as a percentage
between two solid samples. (One solidified
at room temperature and the other under
vacuum).
The density index can be determined by
measuring for both samples their density
value, or by using the "theoretical density"
value for the sample solidified at room
temperature and measuring the density
value only for the vacuum sample. In this
case, you need to tap the "Theoretical
density" key to enter the value.
Then tap the "Start" button to proceed with
the measurement

Optional information about the
measurement to be performed will be
required.
Tap the "Enter" key to confirm.
Now perform the steps shown on the
display to determine the density index.
Database:
By tapping the "database" key, you can
create a custom database to determine the
different density types.
Tap the "New" key and enter the name of
the new record to be stored.
▪ Description: enter a description of the
item.
▪ Measurement type: Select the type of
density to be determined.
After entering all required data, tap the
"Save" key to save the new record.

8.5.1 Screen with the “Density of a solid” calculation function.
Below are the functions for calculating the density of a solid.
Tap the "Esc" key to exit the function, the "Restart" key to make a new measurement, and the
"Print" key to print the measurement result.
8.5.2 Screen with the “Density of a liquid” calculation function
Below are the functions for calculating the density of a liquid.
Tap the "Esc" key to exit the function, the "Restart" key to make a new measurement, and the
"Print" key to print the measurement result.
Detected values for density determination
Detected values for density determination
Information about the database
used:
Record name
Test description
Information about the database
used:
Record name
Test description

8.5.3 Screen with the “Density index” calculation function.
Below are the functions for calculating the density index.
Tap the "Esc" key to exit the function, the "Restart" key to make a new measurement, and the
"Print" key to print the measurement result.
Detected values for density determination
Information about the database
used:
Record name
Test description

8.6 “Statistics” function
This function allows you to perform weighing statistics in simple mode, without defining the
nominal weight and tolerance value, or, using database statistics, you can define the relative
nominal weight and tolerance values. At the end of the procedures in both cases, it is possible
to print the statistical result of the weights.
To access the function from the functions menu, tap the "Statistics" icon.
Select the mode:
Simple statistics: by selecting the simple
function, you can perform the statistics up
to 500 consecutive weights.
Tap the "Simple Statistics" button and
immediately the screen will be activated to
perform the weighing.
Database statistics: by selecting the
statistical mode from the database, you can
store and then recall a custom statistics
method.
By tapping the "database" key, you can
create a custom database to determine the
different density types.
Tap the "New" key and enter the name of
the new record to be stored.
▪ Description: enter a description of the
item.
▪ Nominal weight: enter the nominal
weight value and select the desired
unit of measurement.
▪ Enter values for tolerance check
(Optional Data).
▪ T2+ : 2nd positive tolerance
▪ T2- : 1st negative tolerance
▪ T1+ : 1st positive tolerance
▪ T1- : 1st negative tolerance
After entering all required data, tap the
"Save" key to save the new record. Before
performing the save, a congruity check of
the entered data is performed. An error will
be reported to make the necessary
corrections and retouch the save key.

8.6.1 Screen with “Simple statistics” function
Below are the simple statistical function functions.
Tap the " Ok" key to capture a new weight.
Tap the " T Man" key to enter a manual tare value
Tap the “-T-“ key to run a manual tare
Touch the “- 0 “ key to reset the plate.
Tap the "End" key to end the weighing acquisition and follow the statistical calculation
Tap the "Esc" key to exit the function, the "Restart" key to make a new measurement and the
"Print" key to print the measurement result.
List of the values captured

8.6.2 Screen with “Database statistics” function
Below are the functions related to the database statistics function.
Tap the " Ok" key to capture a new weight.
Tap the " T Man" key to enter a manual tare value
Tap the “-T-“ key to run a manual tare
Touch the “- 0 “ key to reset the plate.
Tap the "End" key to end the weighing acquisition and follow the statistical calculation
Tap the key to delete the last weight captured.
Tap the key to display the weights captured.
Tap the key to display the parameters set for statistical calculation

8.7 “Textile” function
This function determines the title of the yarns by weighing a known length bundle. Also, using
the database function, you can also perform a weighing statistics.
To access the function from the "Functions" menu, tap the "Textile" icon.
Length:
enter the value of the bundle length; the
value can be expressed in meters or yards.
To select the desired unit on the Length
Input Screen, tap the "Units" key and make
the selection.
Units:
select the unit with which you want to view
the result. (Tex, Td, Nm, Nc). However, the
selected unit can still be modified during
weighing by tapping the symbol displayed
to the left of the weight.
Start:
after entering the required data, tap the
"Start" button to execute the "Textile"
function.
Database:
by touching the "database" key, you can
create a custom database for "Textile"
weighing.
Using the database in addition to the
simple "textile" weighing, you can perform
the statistical check of the weights.
Tap the "New" key and enter the name of
the new record to be stored.
▪ Description: enter a description of the
item.
▪ Length: select the desired
measurement unit and enter the length
of the bundle.

▪ Unit: select the unit with which you
want to view the result. (Tex, Td, Nm,
Nc). However, the selected unit can
still be modified during weighing by
tapping the symbol displayed to the left
of the weight
▪ Statistics: you can activate the
statistical check of the weights.
Activating this function, you must enter
the following data:
▪ Nominal value: select the unit of
measurement and enter the nominal
weight value to be checked.
▪ T2+, T2-, T1+, T1-: enter the error
tolerance threshold values. (Optional
entry).
▪ Save: tap the "Save" button to save
the entered record
8.7.1 Screen of the “Textile” function.
Below are the functions in the "Textile" screen.
Tap the "Print" key to print the result.
Tap the “T Man” key to enter a manual tare value
Tap the “-T-“ key to run a manual tare
Touch the “- 0 -“ key to reset the plate.
Bundle length information and
weight value in g
Measured unit
selection key
displayed

8.7.2 Screen of the database textile function with statistics enabled
Below are the functions related to the statistical database textile function.
Tap the "Ok" key to acquire a new weight.
Tap the "T Man" key to enter a manual tare value
Tap the "-T-" key to run a manual tare
Touch the "- 0 -" key to reset the plate.
Tap the "End" key to end the weighing acquisition and follow the statistical calculation
Tap the key to delete the last weight acquired.
Tap the key to view the weights acquired
Tap the key to display the parameters set for statistical calculation

8.8 “Animal weighting” function
This function allows you to measure the weight of unstable samples (i.e. animals) or samples
that are in very unstable environments. The weight is determined in the form of an average
value based on multiple weight measurement cycles within the set time interval.
To access the function from the "Functions" menu, tap the "Animal weighing" icon.
Measurement time:
enter the express measurement time in
seconds. (Minimum value 5 seconds,
maximum 90 seconds)
Start:
after entering the required data, tap the
"Start" button to perform the " Animal
weighing " function.
If necessary, reset the indication or load
any tare.
Load the sample to be analyzed and tap
the "Ok" key.

8.8.1 Screen of the “Animal weighting” function.
Below are the functions in the "Animal weighing" screen.
Tap the "Abort" button to cancel the measurement
Tap the "Stop" button to stop the countdown and display the result
Tap the "Esc" key to exit the function, the "Restart" key to make a new measurement and the
"Print" key to print the measurement result.
.
Information during weight capture
The average value of the
weights captured in the set
time interval
Information at the end of weight capture
Indication of the time
used for the
measurement

8.9 “Maximum load” function
This function allows to measure the maximum breakage load of a solid.
To access the function from the "Functions" menu, tap the "Maximum load" icon.
Selecting the function immediately displays
the measurement screen.
▪ Prepare the sample to be tested on
the weighing plate.
▪ Perform tare or zero reset if
necessary.
▪ Tap the "Ok" key to start the test.
Once the tested sample breakage load is
reached, the maximum weight will be
displayed.
Weight detected on the plate
Tap the "Esc" key to exit the function, the "Restart" key to make a new measurement and the
"Print" key to print the measurement result.

8.10 “Recipe” function
This function allows you to prepare a compound by dosing a set of components in manual
mode "Simple recipe" or by calling a formula with ingredients and tolerances previously
entered in the recipes database.
To access the function from the "Functions" menu, tap the "Recipe" icon.
Simple recipe :
this mode allows you to carry out a series
of consecutive weights and finally get the
total weight of the dosed components and
the relative list with the value of the
individual weights.
Tapping the "Simple recipe" button
immediately displays the measurement
screen.
▪ Load any container and run the tare.
Or, if necessary, reset the indication
with the "0" key.
▪ Now dose the first component and
tap the "Ok" key to confirm the
capture.
▪ Then repeat the operation for all the
components of the recipe.
▪ To finish the dosing operation of the
components, tap the "End" key.

Database recipe:
By tapping the "database" key, you can
create a custom database for the "recipe"
function.
Using the database, you can store custom
recipes with a set of components and their
tolerances.
Tap the "New" key and enter the name of
the new record to be stored.
▪ Description: enter the item
description.
▪ Add: tap the add button to insert a
component.
▪ Name: enter the name of the
component.
▪ Quantity: select the desired unit of
measurement and enter the nominal
quantity of the component.
▪ Toll T+: enter positive percentage
tolerance.
▪ Toll T-: enter negative percentage
tolerance.
▪ Confirmation: tap the confirmation
key to accept the entered values.
Verification of the correctness of the
data entered in case of error signal will
be performed; check that all
parameters entered are congruent.
After confirming, proceed with the "add"
button to enter all the desired components.
▪ Save: after entering all the desired
components, tap the "Save" button to
store the recipe.

To recall the recipe entered in the
database, use the "Select From List"
command, select the recipe you want and
proceed as shown below.
After selecting the desired recipe, a
summary screen will be displayed showing
all the components and their amount
needed to make the recipe.
Tap the "Ok" key to confirm and proceed
by entering the multiplication factor needed
to determine the total amount of the recipe.
(i.e. if the recipe has been stored to
produce 10g of product and you want to
produce 100g insert a "K" factor of 10). If
the entered value does not allow the dosing
of one of the components because its
quantity exceeds the scale capacity, it will
not be accepted.
If the total weight of the recipe instead
exceeds the scale capacity, but the
individual components are lower, it will be
asked whether to proceed with the
"separate recipe".
▪ Yes: to proceed with the separate
recipe.
▪ No: to change the value of the
multiplier factor "K" and reduce the
quantities.
The recipe screen shows the type of recipe
you are using by displaying two symbols as
described below:
Symbol displayed in case of "unique
recipe".
Symbol displayed in case of "separate
recipe ".

8.10.1 Screen of the “Simple recipe” function.
The following are the functions for the simple recipe function.
Tap the "Ok" key to acquire a new weight.
Tap the "End" key to end the weighing capture and follow the statistical calculation
Tap the key to clear the last weight acquired.
Tap the key to view the weight acquired.
After tapping the "End" key, the screen appears with the result of the sum of the weights.
Tap the "Esc" key to exit the function, the "Restart" key to make a new measurement and the
"Print" key to print the measurement result.
.

8.10.2 Screen of the “Database recipe” function.
Below are the features in the "Database recipe" screen.
Tap the "Ok" key to acquire a new weight.
Tap the “T” key to reset the weight indication.
Tap the key to view the list of the recipe components and the components already
entered:
Dosing bar:
The dosing bar works with automatic graduated enlargement. When the dosed quantity
approaches the two levels of tolerance, the center zone is automatically enlarged to allow
dosing with a greater sensitivity.
The bar takes on different colors:
Yellow when the loaded weight is lower than the minimum threshold
Green when the weight is within the set range
Red when the weight is higher than the upper threshold set

If during dosing the amount of dosed component exceeds that allowed by the tolerances, it will
be required to perform automatic adjustment of the recipe with a new total quantity and the
quantity update of all the components of the recipe.
Tap the "Yes" button to confirm the adjustment, press the "No" button to return to the dosing
screen. In this case, you can remove excess quantity or cancel the recipe by tapping the "X"
key.
When the correct dosage of all components is completed, the actual dosed amount will be
displayed:
Tap the key to view the complete list of components and their dosed quantities.
Tap the "Esc" key to exit the function, the "Restart" key to make a new measurement and the
"Print" key to print the measurement result.

8.11 Setting the GLP data
This function allows you to customize and create a database with G.l.p. parameters.
To access the function from the "Functions" menu, tap the "GLP" icon.
GLP Setup: use this command to enter
GLP parameters when you do not want to
save them to the database.
The data entry screen will be displayed.
Tap the corresponding parameter to enter
the desired data.
➢ Scale ID
➢ Project ID
➢ User ID
After entering the data, press the “Ok” key
to confirm.
Note that the maximum number of
characters allowed per parameter is 20.
GLP Database: by tapping this command,
you can access the GLP parameter
database management menu
Below are all the available functions
▪ Selection by name: y tapping this
key, you can call up a program by
entering the corresponding name.
▪ Selection list: by tapping this
button, you can call up a program
by selecting it from a list.
▪ New: by tapping this button, you
can enter a new record.
▪ Edit: by tapping this button, you
can access the GLP parameters
that can be changed.
▪ Delete: tap this button to delete
one or more previously stored
records.
▪ Print: by tapping this button you
can select a GLP record and print
it.
▪ Export (Usb): by tapping this
button, you can export the
database to the USB stick.

▪ Import (Usb): by tapping this key,
you can import from a USB stick a
predefined database previously
The selection, edit, delete, print, export and
import commands are the same as
described in chapter 9.7.1
New: this command allows you to enter a
new record.
Enter the name you want to assign to the
record and confirm with the "Enter" key.
The data entry screen will be displayed.
Tap the corresponding parameter to enter
the desired data.
➢ Scale ID
➢ Project ID
➢ User ID
After entering the data, press the "Save"
key to confirm.
In order to save data, at least one of the
three fields must be filled in, otherwise an
incomplete data screen will be displayed.
After entering the record to select it, use
the "Select from list" or "Select by name"
command.
Tap the desired record and confirm with the
"Ok" key.
N.B. By entering the "GLP" command in
the print setup menu or in the save file,
the data set in the "Balance id, Project
id, User id" fields will be reported.

9 Technical features
The Accuris Tx Analytical models are all intended for indoor use. Maximum installation altitude: 4000m;
Degree of Pollution: 2; Overvoltage category: II
Power supply
unit supplied:
INPUT: Switching 100-240Vac~ 50/ 60Hz, OUTPUT: 24V DC
550mA, Potenza Max absorbed power 13.2VA
Adaptation to
environmental
conditions:
Selectable filters
Autozero:

10 Warranty
▪ The warranty period is 24 months from the date of purchase as per the customer’s printed
purchase order or sales order record from their distributor.
▪ The warranty covers all parts that may have a manufacturing defect. It does not cover
damaged mechanical and electronic parts due to improper installation, tampering, or
improper use.
▪ The warranty does not cover damage caused by shocks, fall of the balance or fall of
objects on the weighing plate.
▪ The transport to and from the Service Center is the responsibility of the customer.
11 Disposal
If the packaging is no longer used, it can be delivered to the local waste disposal
center. The packaging is made entirely of non-polluting materials, recyclable as
valuable secondary raw materials. Discharged batteries should not be disposed of in
normal domestic waste. Drop them into the appropriate collection containers. In case
of scrapping of the device, call the local authorities. Remove the batteries before scrapping
the unit.
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com